Cargando…

Effects of 60 Min Electrostimulation With the EXOPULSE Mollii Suit on Objective Signs of Spasticity

Background: The EXOPULSE Mollii method is an innovative full-body suit approach for non-invasive electrical stimulation, primarily designed to reduce disabling spasticity and improve motor function through the mechanism of reciprocal inhibition. This study aimed to evaluate the effectiveness of one...

Descripción completa

Detalles Bibliográficos
Autores principales: Pennati, Gaia Valentina, Bergling, Hanna, Carment, Loïc, Borg, Jörgen, Lindberg, Påvel G., Palmcrantz, Susanne
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8554021/
https://www.ncbi.nlm.nih.gov/pubmed/34721255
http://dx.doi.org/10.3389/fneur.2021.706610
_version_ 1784591702322839552
author Pennati, Gaia Valentina
Bergling, Hanna
Carment, Loïc
Borg, Jörgen
Lindberg, Påvel G.
Palmcrantz, Susanne
author_facet Pennati, Gaia Valentina
Bergling, Hanna
Carment, Loïc
Borg, Jörgen
Lindberg, Påvel G.
Palmcrantz, Susanne
author_sort Pennati, Gaia Valentina
collection PubMed
description Background: The EXOPULSE Mollii method is an innovative full-body suit approach for non-invasive electrical stimulation, primarily designed to reduce disabling spasticity and improve motor function through the mechanism of reciprocal inhibition. This study aimed to evaluate the effectiveness of one session of stimulation with the EXOPULSE Mollii suit at different stimulation frequencies on objective signs of spasticity and clinical measures, and the subjective perceptions of the intervention. Methods: Twenty patients in the chronic phase after stroke were enrolled in a cross-over, double-blind controlled study. Electrical stimulation delivered through EXOPULSE Mollii was applied for 60 min at two active frequencies (20 and 30 Hz) and in OFF-settings (placebo) in a randomized order, every second day. Spasticity was assessed with controlled-velocity passive muscle stretches using the NeuroFlexor hand and foot modules. Surface electromyography (EMG) for characterizing flexor carpi radialis, medial gastrocnemius, and soleus muscles activation, Modified Ashworth Scale and range of motion were used as complementary tests. Finally, a questionnaire was used to assess the participants' perceptions of using the EXOPULSE Mollii suit. Results: At group level, analyses showed no significant effect of stimulation at any frequency on NeuroFlexor neural component (NC) and EMG amplitude in the upper or lower extremities (p > 0.35). Nevertheless, the effect was highly variable at the individual level, with eight patients exhibiting reduced NC (>1 N) in the upper extremity after stimulation at 30 Hz, 5 at 20 Hz and 3 in OFF settings. All these patients presented severe spasticity at baseline, i.e., NC > 8 N. Modified Ashworth ratings of spasticity and range of motion did not change significantly after stimulation at any frequency. Finally, 75% of participants reported an overall feeling of well-being during stimulation, with 25% patients describing a muscle-relaxing effect on the affected hand and/or foot at both 20 and 30 Hz. Conclusions: The 60 min of electrical stimulation with EXOPULSE Mollii suit did not reduce spasticity consistently in the upper and lower extremities in the chronic phase after stroke. Findings suggest a need for further studies in patients with severe spasticity after stroke including repeated stimulation sessions. Clinical Trial Registration: https://clinicaltrials.gov/ct2/show/NCT04076878, identifier: NCT04076878.
format Online
Article
Text
id pubmed-8554021
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-85540212021-10-30 Effects of 60 Min Electrostimulation With the EXOPULSE Mollii Suit on Objective Signs of Spasticity Pennati, Gaia Valentina Bergling, Hanna Carment, Loïc Borg, Jörgen Lindberg, Påvel G. Palmcrantz, Susanne Front Neurol Neurology Background: The EXOPULSE Mollii method is an innovative full-body suit approach for non-invasive electrical stimulation, primarily designed to reduce disabling spasticity and improve motor function through the mechanism of reciprocal inhibition. This study aimed to evaluate the effectiveness of one session of stimulation with the EXOPULSE Mollii suit at different stimulation frequencies on objective signs of spasticity and clinical measures, and the subjective perceptions of the intervention. Methods: Twenty patients in the chronic phase after stroke were enrolled in a cross-over, double-blind controlled study. Electrical stimulation delivered through EXOPULSE Mollii was applied for 60 min at two active frequencies (20 and 30 Hz) and in OFF-settings (placebo) in a randomized order, every second day. Spasticity was assessed with controlled-velocity passive muscle stretches using the NeuroFlexor hand and foot modules. Surface electromyography (EMG) for characterizing flexor carpi radialis, medial gastrocnemius, and soleus muscles activation, Modified Ashworth Scale and range of motion were used as complementary tests. Finally, a questionnaire was used to assess the participants' perceptions of using the EXOPULSE Mollii suit. Results: At group level, analyses showed no significant effect of stimulation at any frequency on NeuroFlexor neural component (NC) and EMG amplitude in the upper or lower extremities (p > 0.35). Nevertheless, the effect was highly variable at the individual level, with eight patients exhibiting reduced NC (>1 N) in the upper extremity after stimulation at 30 Hz, 5 at 20 Hz and 3 in OFF settings. All these patients presented severe spasticity at baseline, i.e., NC > 8 N. Modified Ashworth ratings of spasticity and range of motion did not change significantly after stimulation at any frequency. Finally, 75% of participants reported an overall feeling of well-being during stimulation, with 25% patients describing a muscle-relaxing effect on the affected hand and/or foot at both 20 and 30 Hz. Conclusions: The 60 min of electrical stimulation with EXOPULSE Mollii suit did not reduce spasticity consistently in the upper and lower extremities in the chronic phase after stroke. Findings suggest a need for further studies in patients with severe spasticity after stroke including repeated stimulation sessions. Clinical Trial Registration: https://clinicaltrials.gov/ct2/show/NCT04076878, identifier: NCT04076878. Frontiers Media S.A. 2021-10-15 /pmc/articles/PMC8554021/ /pubmed/34721255 http://dx.doi.org/10.3389/fneur.2021.706610 Text en Copyright © 2021 Pennati, Bergling, Carment, Borg, Lindberg and Palmcrantz. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neurology
Pennati, Gaia Valentina
Bergling, Hanna
Carment, Loïc
Borg, Jörgen
Lindberg, Påvel G.
Palmcrantz, Susanne
Effects of 60 Min Electrostimulation With the EXOPULSE Mollii Suit on Objective Signs of Spasticity
title Effects of 60 Min Electrostimulation With the EXOPULSE Mollii Suit on Objective Signs of Spasticity
title_full Effects of 60 Min Electrostimulation With the EXOPULSE Mollii Suit on Objective Signs of Spasticity
title_fullStr Effects of 60 Min Electrostimulation With the EXOPULSE Mollii Suit on Objective Signs of Spasticity
title_full_unstemmed Effects of 60 Min Electrostimulation With the EXOPULSE Mollii Suit on Objective Signs of Spasticity
title_short Effects of 60 Min Electrostimulation With the EXOPULSE Mollii Suit on Objective Signs of Spasticity
title_sort effects of 60 min electrostimulation with the exopulse mollii suit on objective signs of spasticity
topic Neurology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8554021/
https://www.ncbi.nlm.nih.gov/pubmed/34721255
http://dx.doi.org/10.3389/fneur.2021.706610
work_keys_str_mv AT pennatigaiavalentina effectsof60minelectrostimulationwiththeexopulsemolliisuitonobjectivesignsofspasticity
AT berglinghanna effectsof60minelectrostimulationwiththeexopulsemolliisuitonobjectivesignsofspasticity
AT carmentloic effectsof60minelectrostimulationwiththeexopulsemolliisuitonobjectivesignsofspasticity
AT borgjorgen effectsof60minelectrostimulationwiththeexopulsemolliisuitonobjectivesignsofspasticity
AT lindbergpavelg effectsof60minelectrostimulationwiththeexopulsemolliisuitonobjectivesignsofspasticity
AT palmcrantzsusanne effectsof60minelectrostimulationwiththeexopulsemolliisuitonobjectivesignsofspasticity