Cargando…

Digital Leg Volume Quantification: Precision Assessment of a Novel Workflow Based on Single Capture Three-dimensional Whole-Body Surface Imaging

Whole-body three-dimensional surface imaging (3DSI) offers the ability to monitor morphologic changes in multiple areas without the need to individually scan every anatomical region of interest. One area of application is the digital quantification of leg volume. Certain types of morphology do not p...

Descripción completa

Detalles Bibliográficos
Autores principales: Etzel, Lucas, Schenck, Thilo L., Giunta, Riccardo E., Li, Zhouxiao, Xu, Ya, Koban, Konstantin C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8554908/
https://www.ncbi.nlm.nih.gov/pubmed/34581929
http://dx.doi.org/10.1007/s10278-021-00493-8
_version_ 1784591881687007232
author Etzel, Lucas
Schenck, Thilo L.
Giunta, Riccardo E.
Li, Zhouxiao
Xu, Ya
Koban, Konstantin C.
author_facet Etzel, Lucas
Schenck, Thilo L.
Giunta, Riccardo E.
Li, Zhouxiao
Xu, Ya
Koban, Konstantin C.
author_sort Etzel, Lucas
collection PubMed
description Whole-body three-dimensional surface imaging (3DSI) offers the ability to monitor morphologic changes in multiple areas without the need to individually scan every anatomical region of interest. One area of application is the digital quantification of leg volume. Certain types of morphology do not permit complete circumferential scan of the leg surface. A workflow capable of precisely estimating the missing data is therefore required. We thus aimed to describe and apply a novel workflow to collect bilateral leg volume measurements from whole-body 3D surface scans regardless of leg morphology and to assess workflow precision. For each study participant, whole-body 3DSI was conducted twice successively in a single session with subject repositioning between scans. Paired samples of bilateral leg volume were calculated from the 3D surface data, with workflow variations for complete and limited leg surface visibility. Workflow precision was assessed by calculating the relative percent differences between repeated leg volumes. A total of 82 subjects were included in this study. The mean relative differences between paired left and right leg volumes were 0.73 ± 0.62% and 0.82 ± 0.65%. The workflow variations for completely and partially visible leg surfaces yielded similarly low values. The workflow examined in this study provides a precise method to digitally monitor leg volume regardless of leg morphology. It could aid in objectively comparing medical treatment options of the leg in a clinical setting. Whole-body scans acquired using the described 3DSI routine may allow simultaneous assessment of other changes in body morphology after further validation.
format Online
Article
Text
id pubmed-8554908
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-85549082021-11-10 Digital Leg Volume Quantification: Precision Assessment of a Novel Workflow Based on Single Capture Three-dimensional Whole-Body Surface Imaging Etzel, Lucas Schenck, Thilo L. Giunta, Riccardo E. Li, Zhouxiao Xu, Ya Koban, Konstantin C. J Digit Imaging Original Paper Whole-body three-dimensional surface imaging (3DSI) offers the ability to monitor morphologic changes in multiple areas without the need to individually scan every anatomical region of interest. One area of application is the digital quantification of leg volume. Certain types of morphology do not permit complete circumferential scan of the leg surface. A workflow capable of precisely estimating the missing data is therefore required. We thus aimed to describe and apply a novel workflow to collect bilateral leg volume measurements from whole-body 3D surface scans regardless of leg morphology and to assess workflow precision. For each study participant, whole-body 3DSI was conducted twice successively in a single session with subject repositioning between scans. Paired samples of bilateral leg volume were calculated from the 3D surface data, with workflow variations for complete and limited leg surface visibility. Workflow precision was assessed by calculating the relative percent differences between repeated leg volumes. A total of 82 subjects were included in this study. The mean relative differences between paired left and right leg volumes were 0.73 ± 0.62% and 0.82 ± 0.65%. The workflow variations for completely and partially visible leg surfaces yielded similarly low values. The workflow examined in this study provides a precise method to digitally monitor leg volume regardless of leg morphology. It could aid in objectively comparing medical treatment options of the leg in a clinical setting. Whole-body scans acquired using the described 3DSI routine may allow simultaneous assessment of other changes in body morphology after further validation. Springer International Publishing 2021-09-28 2021-10 /pmc/articles/PMC8554908/ /pubmed/34581929 http://dx.doi.org/10.1007/s10278-021-00493-8 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Paper
Etzel, Lucas
Schenck, Thilo L.
Giunta, Riccardo E.
Li, Zhouxiao
Xu, Ya
Koban, Konstantin C.
Digital Leg Volume Quantification: Precision Assessment of a Novel Workflow Based on Single Capture Three-dimensional Whole-Body Surface Imaging
title Digital Leg Volume Quantification: Precision Assessment of a Novel Workflow Based on Single Capture Three-dimensional Whole-Body Surface Imaging
title_full Digital Leg Volume Quantification: Precision Assessment of a Novel Workflow Based on Single Capture Three-dimensional Whole-Body Surface Imaging
title_fullStr Digital Leg Volume Quantification: Precision Assessment of a Novel Workflow Based on Single Capture Three-dimensional Whole-Body Surface Imaging
title_full_unstemmed Digital Leg Volume Quantification: Precision Assessment of a Novel Workflow Based on Single Capture Three-dimensional Whole-Body Surface Imaging
title_short Digital Leg Volume Quantification: Precision Assessment of a Novel Workflow Based on Single Capture Three-dimensional Whole-Body Surface Imaging
title_sort digital leg volume quantification: precision assessment of a novel workflow based on single capture three-dimensional whole-body surface imaging
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8554908/
https://www.ncbi.nlm.nih.gov/pubmed/34581929
http://dx.doi.org/10.1007/s10278-021-00493-8
work_keys_str_mv AT etzellucas digitallegvolumequantificationprecisionassessmentofanovelworkflowbasedonsinglecapturethreedimensionalwholebodysurfaceimaging
AT schenckthilol digitallegvolumequantificationprecisionassessmentofanovelworkflowbasedonsinglecapturethreedimensionalwholebodysurfaceimaging
AT giuntariccardoe digitallegvolumequantificationprecisionassessmentofanovelworkflowbasedonsinglecapturethreedimensionalwholebodysurfaceimaging
AT lizhouxiao digitallegvolumequantificationprecisionassessmentofanovelworkflowbasedonsinglecapturethreedimensionalwholebodysurfaceimaging
AT xuya digitallegvolumequantificationprecisionassessmentofanovelworkflowbasedonsinglecapturethreedimensionalwholebodysurfaceimaging
AT kobankonstantinc digitallegvolumequantificationprecisionassessmentofanovelworkflowbasedonsinglecapturethreedimensionalwholebodysurfaceimaging