Cargando…

Tracheal intubation while wearing personal protective equipment in simulation studies: a systematic review and meta-analysis with trial-sequential analysis

BACKGROUND: Tracheal intubation in patients with coronavirus disease-19 is a high-risk procedure that should be performed with personal protective equipment (PPE). The influence of PPE on operator’s performance during tracheal intubation remains unclear. METHODS: We conducted a systematic review and...

Descripción completa

Detalles Bibliográficos
Autores principales: Sanfilippo, Filippo, Tigano, Stefano, La Rosa, Valeria, Morgana, Alberto, Murabito, Paolo, Oliveri, Francesco, Longhini, Federico, Astuto, Marinella
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8556077/
https://www.ncbi.nlm.nih.gov/pubmed/34624372
http://dx.doi.org/10.1016/j.bjane.2021.08.017
_version_ 1784592109060227072
author Sanfilippo, Filippo
Tigano, Stefano
La Rosa, Valeria
Morgana, Alberto
Murabito, Paolo
Oliveri, Francesco
Longhini, Federico
Astuto, Marinella
author_facet Sanfilippo, Filippo
Tigano, Stefano
La Rosa, Valeria
Morgana, Alberto
Murabito, Paolo
Oliveri, Francesco
Longhini, Federico
Astuto, Marinella
author_sort Sanfilippo, Filippo
collection PubMed
description BACKGROUND: Tracheal intubation in patients with coronavirus disease-19 is a high-risk procedure that should be performed with personal protective equipment (PPE). The influence of PPE on operator’s performance during tracheal intubation remains unclear. METHODS: We conducted a systematic review and meta-analysis of simulation studies to evaluate the influence of wearing PPE as compared to standard uniform regarding time-to-intubation (TTI) and success rate. Subgroup analyses were conducted according to device used and operator’s experience. RESULTS: The TTI was prolonged when wearing PPE (eight studies): Standard Mean Difference (SMD) -0.54, 95% Confidence Interval [-0.75, -0.34], p <  0.0001. Subgroup analyses according to device used showed similar findings (direct laryngoscopy, SMD -0.63 [-0.88, -0.38], p < 0.0001; videolaryngoscopy, SMD -0.39 [-0.75, -0.02], p =  0.04). Considering the operator’s experience, non-anesthesiologists had prolonged TTI (SMD -0.75 [-0.98, -0.52], p < 0.0001) while the analysis on anesthesiologists did not show significant differences (SMD -0.25 [-0.51, 0.01], p = 0.06). The success rate of tracheal intubation was not influenced by PPE: Risk Ratio (RR) 1.02 [1.00, 1.04]; p = 0.12). Subgroup analyses according to device demonstrated similar results (direct laryngoscopy, RR 1.03 [0.99, 1.07], p = 0.15, videolaryngoscopy, RR 1.01 [0.98, 1.04], p =  0.52). Wearing PPE had a trend towards negative influence on success rate in non-anesthesiologists (RR 1.05 [1.00, 1.10], p = 0.05), but not in anesthesiologists (RR 1.00 [0.98, 1.03], p = 0.84). Trial-sequential analyses for TTI and success rate indicated robustness of both results. CONCLUSIONS: Under simulated conditions, wearing PPE delays the TTI as compared to dressing standard uniform, with no influence on the success rate. However, certainty of evidence is very low. Performing tracheal intubation with direct laryngoscopy seems influenced to a greater extent as compared to videolaryngoscopy. Similarly, wearing PPE affects more the non-anesthesiologists subgroup as compared to anesthesiologists.
format Online
Article
Text
id pubmed-8556077
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-85560772021-11-01 Tracheal intubation while wearing personal protective equipment in simulation studies: a systematic review and meta-analysis with trial-sequential analysis Sanfilippo, Filippo Tigano, Stefano La Rosa, Valeria Morgana, Alberto Murabito, Paolo Oliveri, Francesco Longhini, Federico Astuto, Marinella Braz J Anesthesiol Systematic Review BACKGROUND: Tracheal intubation in patients with coronavirus disease-19 is a high-risk procedure that should be performed with personal protective equipment (PPE). The influence of PPE on operator’s performance during tracheal intubation remains unclear. METHODS: We conducted a systematic review and meta-analysis of simulation studies to evaluate the influence of wearing PPE as compared to standard uniform regarding time-to-intubation (TTI) and success rate. Subgroup analyses were conducted according to device used and operator’s experience. RESULTS: The TTI was prolonged when wearing PPE (eight studies): Standard Mean Difference (SMD) -0.54, 95% Confidence Interval [-0.75, -0.34], p <  0.0001. Subgroup analyses according to device used showed similar findings (direct laryngoscopy, SMD -0.63 [-0.88, -0.38], p < 0.0001; videolaryngoscopy, SMD -0.39 [-0.75, -0.02], p =  0.04). Considering the operator’s experience, non-anesthesiologists had prolonged TTI (SMD -0.75 [-0.98, -0.52], p < 0.0001) while the analysis on anesthesiologists did not show significant differences (SMD -0.25 [-0.51, 0.01], p = 0.06). The success rate of tracheal intubation was not influenced by PPE: Risk Ratio (RR) 1.02 [1.00, 1.04]; p = 0.12). Subgroup analyses according to device demonstrated similar results (direct laryngoscopy, RR 1.03 [0.99, 1.07], p = 0.15, videolaryngoscopy, RR 1.01 [0.98, 1.04], p =  0.52). Wearing PPE had a trend towards negative influence on success rate in non-anesthesiologists (RR 1.05 [1.00, 1.10], p = 0.05), but not in anesthesiologists (RR 1.00 [0.98, 1.03], p = 0.84). Trial-sequential analyses for TTI and success rate indicated robustness of both results. CONCLUSIONS: Under simulated conditions, wearing PPE delays the TTI as compared to dressing standard uniform, with no influence on the success rate. However, certainty of evidence is very low. Performing tracheal intubation with direct laryngoscopy seems influenced to a greater extent as compared to videolaryngoscopy. Similarly, wearing PPE affects more the non-anesthesiologists subgroup as compared to anesthesiologists. Elsevier 2021-10-12 /pmc/articles/PMC8556077/ /pubmed/34624372 http://dx.doi.org/10.1016/j.bjane.2021.08.017 Text en © 2021 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Systematic Review
Sanfilippo, Filippo
Tigano, Stefano
La Rosa, Valeria
Morgana, Alberto
Murabito, Paolo
Oliveri, Francesco
Longhini, Federico
Astuto, Marinella
Tracheal intubation while wearing personal protective equipment in simulation studies: a systematic review and meta-analysis with trial-sequential analysis
title Tracheal intubation while wearing personal protective equipment in simulation studies: a systematic review and meta-analysis with trial-sequential analysis
title_full Tracheal intubation while wearing personal protective equipment in simulation studies: a systematic review and meta-analysis with trial-sequential analysis
title_fullStr Tracheal intubation while wearing personal protective equipment in simulation studies: a systematic review and meta-analysis with trial-sequential analysis
title_full_unstemmed Tracheal intubation while wearing personal protective equipment in simulation studies: a systematic review and meta-analysis with trial-sequential analysis
title_short Tracheal intubation while wearing personal protective equipment in simulation studies: a systematic review and meta-analysis with trial-sequential analysis
title_sort tracheal intubation while wearing personal protective equipment in simulation studies: a systematic review and meta-analysis with trial-sequential analysis
topic Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8556077/
https://www.ncbi.nlm.nih.gov/pubmed/34624372
http://dx.doi.org/10.1016/j.bjane.2021.08.017
work_keys_str_mv AT sanfilippofilippo trachealintubationwhilewearingpersonalprotectiveequipmentinsimulationstudiesasystematicreviewandmetaanalysiswithtrialsequentialanalysis
AT tiganostefano trachealintubationwhilewearingpersonalprotectiveequipmentinsimulationstudiesasystematicreviewandmetaanalysiswithtrialsequentialanalysis
AT larosavaleria trachealintubationwhilewearingpersonalprotectiveequipmentinsimulationstudiesasystematicreviewandmetaanalysiswithtrialsequentialanalysis
AT morganaalberto trachealintubationwhilewearingpersonalprotectiveequipmentinsimulationstudiesasystematicreviewandmetaanalysiswithtrialsequentialanalysis
AT murabitopaolo trachealintubationwhilewearingpersonalprotectiveequipmentinsimulationstudiesasystematicreviewandmetaanalysiswithtrialsequentialanalysis
AT oliverifrancesco trachealintubationwhilewearingpersonalprotectiveequipmentinsimulationstudiesasystematicreviewandmetaanalysiswithtrialsequentialanalysis
AT longhinifederico trachealintubationwhilewearingpersonalprotectiveequipmentinsimulationstudiesasystematicreviewandmetaanalysiswithtrialsequentialanalysis
AT astutomarinella trachealintubationwhilewearingpersonalprotectiveequipmentinsimulationstudiesasystematicreviewandmetaanalysiswithtrialsequentialanalysis