Cargando…
A mobile application tool for standing posture analysis: development, validity, and reliability
BACKGROUND: Using mobile application for postural assessments has been drawing a rising interest due to widespread use of smartphones. Although there are some mobile applications in use, validated mobile tools for accurate postural assessment are still warranted. AIMS: This study aimed to develop Fi...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8556145/ https://www.ncbi.nlm.nih.gov/pubmed/34716535 http://dx.doi.org/10.1007/s11845-021-02827-5 |
_version_ | 1784592124525674496 |
---|---|
author | Timurtaş, Eren Avcı, Ender Ersin Mate, Kedar Karabacak, Neslihan Polat, Mine Gülden Demirbüken, İlkşan |
author_facet | Timurtaş, Eren Avcı, Ender Ersin Mate, Kedar Karabacak, Neslihan Polat, Mine Gülden Demirbüken, İlkşan |
author_sort | Timurtaş, Eren |
collection | PubMed |
description | BACKGROUND: Using mobile application for postural assessments has been drawing a rising interest due to widespread use of smartphones. Although there are some mobile applications in use, validated mobile tools for accurate postural assessment are still warranted. AIMS: This study aimed to develop Fizyoprint mobile application tool to assess standing posture and investigate the validity and reliability of the application in young adults. METHODS: A convenience sample of 20 young adults (12 men and 8 women with a mean age of 21.3 ± 2.2 years) and 2 physiotherapists as raters participated in the study. The participant’s digital images were obtained from the anterior, posterior, and right lateral sides. The raters selected the anatomic reference points by using digital markers in the app screen, and the Fizyoprint application, with Turkish language option, calculated a total of 26 posture variables, including 11 distance and 15 angle variables. Each participant was assessed twice (1-week interval) by 2 raters with Fizyoprint. Inter- and intra-rater reliabilities were estimated using the intraclass correlation coefficient. The BioTonix™ posture analysis system was used for validation. RESULTS: A total of 80.7% (21 variables) indicated acceptable to excellent intra-rater reliability results. A total of 57.7% (15 variables) were found to be acceptable to excellent for inter-rater measurements. The results confirmed the validity of the Fizyoprint application for testing the standing posture. CONCLUSIONS: Fizyoprint application is a new, valid, free mobile tool with acceptable concordance with BioTonix™ postural analysis system for assessing standing posture. Further studies are warranted to test the current application in different populations and musculoskeletal conditions. |
format | Online Article Text |
id | pubmed-8556145 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-85561452021-11-01 A mobile application tool for standing posture analysis: development, validity, and reliability Timurtaş, Eren Avcı, Ender Ersin Mate, Kedar Karabacak, Neslihan Polat, Mine Gülden Demirbüken, İlkşan Ir J Med Sci Original Article BACKGROUND: Using mobile application for postural assessments has been drawing a rising interest due to widespread use of smartphones. Although there are some mobile applications in use, validated mobile tools for accurate postural assessment are still warranted. AIMS: This study aimed to develop Fizyoprint mobile application tool to assess standing posture and investigate the validity and reliability of the application in young adults. METHODS: A convenience sample of 20 young adults (12 men and 8 women with a mean age of 21.3 ± 2.2 years) and 2 physiotherapists as raters participated in the study. The participant’s digital images were obtained from the anterior, posterior, and right lateral sides. The raters selected the anatomic reference points by using digital markers in the app screen, and the Fizyoprint application, with Turkish language option, calculated a total of 26 posture variables, including 11 distance and 15 angle variables. Each participant was assessed twice (1-week interval) by 2 raters with Fizyoprint. Inter- and intra-rater reliabilities were estimated using the intraclass correlation coefficient. The BioTonix™ posture analysis system was used for validation. RESULTS: A total of 80.7% (21 variables) indicated acceptable to excellent intra-rater reliability results. A total of 57.7% (15 variables) were found to be acceptable to excellent for inter-rater measurements. The results confirmed the validity of the Fizyoprint application for testing the standing posture. CONCLUSIONS: Fizyoprint application is a new, valid, free mobile tool with acceptable concordance with BioTonix™ postural analysis system for assessing standing posture. Further studies are warranted to test the current application in different populations and musculoskeletal conditions. Springer International Publishing 2021-10-30 2022 /pmc/articles/PMC8556145/ /pubmed/34716535 http://dx.doi.org/10.1007/s11845-021-02827-5 Text en © The Author(s), under exclusive licence to Royal Academy of Medicine in Ireland 2021 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic. |
spellingShingle | Original Article Timurtaş, Eren Avcı, Ender Ersin Mate, Kedar Karabacak, Neslihan Polat, Mine Gülden Demirbüken, İlkşan A mobile application tool for standing posture analysis: development, validity, and reliability |
title | A mobile application tool for standing posture analysis: development, validity, and reliability |
title_full | A mobile application tool for standing posture analysis: development, validity, and reliability |
title_fullStr | A mobile application tool for standing posture analysis: development, validity, and reliability |
title_full_unstemmed | A mobile application tool for standing posture analysis: development, validity, and reliability |
title_short | A mobile application tool for standing posture analysis: development, validity, and reliability |
title_sort | mobile application tool for standing posture analysis: development, validity, and reliability |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8556145/ https://www.ncbi.nlm.nih.gov/pubmed/34716535 http://dx.doi.org/10.1007/s11845-021-02827-5 |
work_keys_str_mv | AT timurtaseren amobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability AT avcıenderersin amobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability AT matekedar amobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability AT karabacakneslihan amobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability AT polatminegulden amobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability AT demirbukenilksan amobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability AT timurtaseren mobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability AT avcıenderersin mobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability AT matekedar mobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability AT karabacakneslihan mobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability AT polatminegulden mobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability AT demirbukenilksan mobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability |