Cargando…

A mobile application tool for standing posture analysis: development, validity, and reliability

BACKGROUND: Using mobile application for postural assessments has been drawing a rising interest due to widespread use of smartphones. Although there are some mobile applications in use, validated mobile tools for accurate postural assessment are still warranted. AIMS: This study aimed to develop Fi...

Descripción completa

Detalles Bibliográficos
Autores principales: Timurtaş, Eren, Avcı, Ender Ersin, Mate, Kedar, Karabacak, Neslihan, Polat, Mine Gülden, Demirbüken, İlkşan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8556145/
https://www.ncbi.nlm.nih.gov/pubmed/34716535
http://dx.doi.org/10.1007/s11845-021-02827-5
_version_ 1784592124525674496
author Timurtaş, Eren
Avcı, Ender Ersin
Mate, Kedar
Karabacak, Neslihan
Polat, Mine Gülden
Demirbüken, İlkşan
author_facet Timurtaş, Eren
Avcı, Ender Ersin
Mate, Kedar
Karabacak, Neslihan
Polat, Mine Gülden
Demirbüken, İlkşan
author_sort Timurtaş, Eren
collection PubMed
description BACKGROUND: Using mobile application for postural assessments has been drawing a rising interest due to widespread use of smartphones. Although there are some mobile applications in use, validated mobile tools for accurate postural assessment are still warranted. AIMS: This study aimed to develop Fizyoprint mobile application tool to assess standing posture and investigate the validity and reliability of the application in young adults. METHODS: A convenience sample of 20 young adults (12 men and 8 women with a mean age of 21.3 ± 2.2 years) and 2 physiotherapists as raters participated in the study. The participant’s digital images were obtained from the anterior, posterior, and right lateral sides. The raters selected the anatomic reference points by using digital markers in the app screen, and the Fizyoprint application, with Turkish language option, calculated a total of 26 posture variables, including 11 distance and 15 angle variables. Each participant was assessed twice (1-week interval) by 2 raters with Fizyoprint. Inter- and intra-rater reliabilities were estimated using the intraclass correlation coefficient. The BioTonix™ posture analysis system was used for validation. RESULTS: A total of 80.7% (21 variables) indicated acceptable to excellent intra-rater reliability results. A total of 57.7% (15 variables) were found to be acceptable to excellent for inter-rater measurements. The results confirmed the validity of the Fizyoprint application for testing the standing posture. CONCLUSIONS: Fizyoprint application is a new, valid, free mobile tool with acceptable concordance with BioTonix™ postural analysis system for assessing standing posture. Further studies are warranted to test the current application in different populations and musculoskeletal conditions.
format Online
Article
Text
id pubmed-8556145
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-85561452021-11-01 A mobile application tool for standing posture analysis: development, validity, and reliability Timurtaş, Eren Avcı, Ender Ersin Mate, Kedar Karabacak, Neslihan Polat, Mine Gülden Demirbüken, İlkşan Ir J Med Sci Original Article BACKGROUND: Using mobile application for postural assessments has been drawing a rising interest due to widespread use of smartphones. Although there are some mobile applications in use, validated mobile tools for accurate postural assessment are still warranted. AIMS: This study aimed to develop Fizyoprint mobile application tool to assess standing posture and investigate the validity and reliability of the application in young adults. METHODS: A convenience sample of 20 young adults (12 men and 8 women with a mean age of 21.3 ± 2.2 years) and 2 physiotherapists as raters participated in the study. The participant’s digital images were obtained from the anterior, posterior, and right lateral sides. The raters selected the anatomic reference points by using digital markers in the app screen, and the Fizyoprint application, with Turkish language option, calculated a total of 26 posture variables, including 11 distance and 15 angle variables. Each participant was assessed twice (1-week interval) by 2 raters with Fizyoprint. Inter- and intra-rater reliabilities were estimated using the intraclass correlation coefficient. The BioTonix™ posture analysis system was used for validation. RESULTS: A total of 80.7% (21 variables) indicated acceptable to excellent intra-rater reliability results. A total of 57.7% (15 variables) were found to be acceptable to excellent for inter-rater measurements. The results confirmed the validity of the Fizyoprint application for testing the standing posture. CONCLUSIONS: Fizyoprint application is a new, valid, free mobile tool with acceptable concordance with BioTonix™ postural analysis system for assessing standing posture. Further studies are warranted to test the current application in different populations and musculoskeletal conditions. Springer International Publishing 2021-10-30 2022 /pmc/articles/PMC8556145/ /pubmed/34716535 http://dx.doi.org/10.1007/s11845-021-02827-5 Text en © The Author(s), under exclusive licence to Royal Academy of Medicine in Ireland 2021 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Original Article
Timurtaş, Eren
Avcı, Ender Ersin
Mate, Kedar
Karabacak, Neslihan
Polat, Mine Gülden
Demirbüken, İlkşan
A mobile application tool for standing posture analysis: development, validity, and reliability
title A mobile application tool for standing posture analysis: development, validity, and reliability
title_full A mobile application tool for standing posture analysis: development, validity, and reliability
title_fullStr A mobile application tool for standing posture analysis: development, validity, and reliability
title_full_unstemmed A mobile application tool for standing posture analysis: development, validity, and reliability
title_short A mobile application tool for standing posture analysis: development, validity, and reliability
title_sort mobile application tool for standing posture analysis: development, validity, and reliability
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8556145/
https://www.ncbi.nlm.nih.gov/pubmed/34716535
http://dx.doi.org/10.1007/s11845-021-02827-5
work_keys_str_mv AT timurtaseren amobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability
AT avcıenderersin amobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability
AT matekedar amobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability
AT karabacakneslihan amobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability
AT polatminegulden amobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability
AT demirbukenilksan amobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability
AT timurtaseren mobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability
AT avcıenderersin mobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability
AT matekedar mobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability
AT karabacakneslihan mobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability
AT polatminegulden mobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability
AT demirbukenilksan mobileapplicationtoolforstandingpostureanalysisdevelopmentvalidityandreliability