Cargando…
Semi-quantitative measurements of chemokine receptor 4-targeted (68)Ga-pentixafor PET/CT in response assessment of Waldenström macroglobulinemia/lymphoplasmacytic lymphoma
PURPOSE: (68)Ga-pentixafor PET/CT was reported to have a high sensitivity in detecting tumor involvement of Waldenström macroglobulinemia/lymphoplasmacytic lymphoma (WM/LPL) in our previous study. We aimed to further investigate the semi-quantitative measurements of (68)Ga-pentixafor PET/CT in respo...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8556471/ https://www.ncbi.nlm.nih.gov/pubmed/34714390 http://dx.doi.org/10.1186/s13550-021-00852-0 |
_version_ | 1784592173829718016 |
---|---|
author | Pan, Qingqing Cao, Xinxin Luo, Yaping Li, Jian Li, Fang |
author_facet | Pan, Qingqing Cao, Xinxin Luo, Yaping Li, Jian Li, Fang |
author_sort | Pan, Qingqing |
collection | PubMed |
description | PURPOSE: (68)Ga-pentixafor PET/CT was reported to have a high sensitivity in detecting tumor involvement of Waldenström macroglobulinemia/lymphoplasmacytic lymphoma (WM/LPL) in our previous study. We aimed to further investigate the semi-quantitative measurements of (68)Ga-pentixafor PET/CT in response assessment in WM/LPL. METHODS: Fifteen patients with WM/LPL were recruited in a prospective cohort study and underwent both (68)Ga-pentixafor and (18)F-FDG PET/CT at baseline and post-treatment. PET/CT-based responses were analyzed with semi-quantitative assessments of metabolic tumor volume (MTV) and total lesions glycolysis/uptake (TLG(FDG) and TLU(CXCR4)), and the correlation between PET/CT-based response and clinical response, monoclonal protein and IgM response was analyzed. RESULTS: After chemotherapy, 5 patients had complete response or very good partial response, 8 had partial response or minimal response and 2 had progressive disease. In quantitative analysis, (68)Ga-pentixafor PET/CT-based response (measured in ∆TLU(CXCR4)%, ∆MTV(CXCR4)%, ∆SUVpeak%) showed a significant direct correlation with clinical response, monoclonal protein and IgM response (p < 0.01). However, (18)F-FDG PET/CT-based response was independent from clinical response (p > 0.05). CONCLUSIONS: The semi-quantitative measurements of (68)Ga-pentixafor PET/CT outperformed (18)F-FDG PET/CT in response assessment of WM/LPL. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13550-021-00852-0. |
format | Online Article Text |
id | pubmed-8556471 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-85564712021-11-15 Semi-quantitative measurements of chemokine receptor 4-targeted (68)Ga-pentixafor PET/CT in response assessment of Waldenström macroglobulinemia/lymphoplasmacytic lymphoma Pan, Qingqing Cao, Xinxin Luo, Yaping Li, Jian Li, Fang EJNMMI Res Original Research PURPOSE: (68)Ga-pentixafor PET/CT was reported to have a high sensitivity in detecting tumor involvement of Waldenström macroglobulinemia/lymphoplasmacytic lymphoma (WM/LPL) in our previous study. We aimed to further investigate the semi-quantitative measurements of (68)Ga-pentixafor PET/CT in response assessment in WM/LPL. METHODS: Fifteen patients with WM/LPL were recruited in a prospective cohort study and underwent both (68)Ga-pentixafor and (18)F-FDG PET/CT at baseline and post-treatment. PET/CT-based responses were analyzed with semi-quantitative assessments of metabolic tumor volume (MTV) and total lesions glycolysis/uptake (TLG(FDG) and TLU(CXCR4)), and the correlation between PET/CT-based response and clinical response, monoclonal protein and IgM response was analyzed. RESULTS: After chemotherapy, 5 patients had complete response or very good partial response, 8 had partial response or minimal response and 2 had progressive disease. In quantitative analysis, (68)Ga-pentixafor PET/CT-based response (measured in ∆TLU(CXCR4)%, ∆MTV(CXCR4)%, ∆SUVpeak%) showed a significant direct correlation with clinical response, monoclonal protein and IgM response (p < 0.01). However, (18)F-FDG PET/CT-based response was independent from clinical response (p > 0.05). CONCLUSIONS: The semi-quantitative measurements of (68)Ga-pentixafor PET/CT outperformed (18)F-FDG PET/CT in response assessment of WM/LPL. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13550-021-00852-0. Springer Berlin Heidelberg 2021-10-29 /pmc/articles/PMC8556471/ /pubmed/34714390 http://dx.doi.org/10.1186/s13550-021-00852-0 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Research Pan, Qingqing Cao, Xinxin Luo, Yaping Li, Jian Li, Fang Semi-quantitative measurements of chemokine receptor 4-targeted (68)Ga-pentixafor PET/CT in response assessment of Waldenström macroglobulinemia/lymphoplasmacytic lymphoma |
title | Semi-quantitative measurements of chemokine receptor 4-targeted (68)Ga-pentixafor PET/CT in response assessment of Waldenström macroglobulinemia/lymphoplasmacytic lymphoma |
title_full | Semi-quantitative measurements of chemokine receptor 4-targeted (68)Ga-pentixafor PET/CT in response assessment of Waldenström macroglobulinemia/lymphoplasmacytic lymphoma |
title_fullStr | Semi-quantitative measurements of chemokine receptor 4-targeted (68)Ga-pentixafor PET/CT in response assessment of Waldenström macroglobulinemia/lymphoplasmacytic lymphoma |
title_full_unstemmed | Semi-quantitative measurements of chemokine receptor 4-targeted (68)Ga-pentixafor PET/CT in response assessment of Waldenström macroglobulinemia/lymphoplasmacytic lymphoma |
title_short | Semi-quantitative measurements of chemokine receptor 4-targeted (68)Ga-pentixafor PET/CT in response assessment of Waldenström macroglobulinemia/lymphoplasmacytic lymphoma |
title_sort | semi-quantitative measurements of chemokine receptor 4-targeted (68)ga-pentixafor pet/ct in response assessment of waldenström macroglobulinemia/lymphoplasmacytic lymphoma |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8556471/ https://www.ncbi.nlm.nih.gov/pubmed/34714390 http://dx.doi.org/10.1186/s13550-021-00852-0 |
work_keys_str_mv | AT panqingqing semiquantitativemeasurementsofchemokinereceptor4targeted68gapentixaforpetctinresponseassessmentofwaldenstrommacroglobulinemialymphoplasmacyticlymphoma AT caoxinxin semiquantitativemeasurementsofchemokinereceptor4targeted68gapentixaforpetctinresponseassessmentofwaldenstrommacroglobulinemialymphoplasmacyticlymphoma AT luoyaping semiquantitativemeasurementsofchemokinereceptor4targeted68gapentixaforpetctinresponseassessmentofwaldenstrommacroglobulinemialymphoplasmacyticlymphoma AT lijian semiquantitativemeasurementsofchemokinereceptor4targeted68gapentixaforpetctinresponseassessmentofwaldenstrommacroglobulinemialymphoplasmacyticlymphoma AT lifang semiquantitativemeasurementsofchemokinereceptor4targeted68gapentixaforpetctinresponseassessmentofwaldenstrommacroglobulinemialymphoplasmacyticlymphoma |