Cargando…
A practical biphasic contrast media injection protocol strongly enhances the aorta and pulmonary artery simultaneously using a single CT angiography scan
BACKGROUND: Enhancement profiles of the pulmonary artery (PA) and aorta differ when using computed tomography (CT) angiography. Our aim was to determine the optimal CT protocol for a one-time CT scan that assesses both blood vessels. METHODS: We prospectively enrolled 101 cases of CT angiography in...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8557493/ https://www.ncbi.nlm.nih.gov/pubmed/34717585 http://dx.doi.org/10.1186/s12880-021-00691-4 |
_version_ | 1784592382675648512 |
---|---|
author | Hsieh, Cheng-Chih Zeng, An-Bang Chen, Chia-Hung Jhou, Zong-Yi Wang, Chih-Hsin Yang, Ya-Ling Hsieh, Feng-Chuan Lin, Jing-Kai Yeh, Ju-Yen Huang, Chun-Chao |
author_facet | Hsieh, Cheng-Chih Zeng, An-Bang Chen, Chia-Hung Jhou, Zong-Yi Wang, Chih-Hsin Yang, Ya-Ling Hsieh, Feng-Chuan Lin, Jing-Kai Yeh, Ju-Yen Huang, Chun-Chao |
author_sort | Hsieh, Cheng-Chih |
collection | PubMed |
description | BACKGROUND: Enhancement profiles of the pulmonary artery (PA) and aorta differ when using computed tomography (CT) angiography. Our aim was to determine the optimal CT protocol for a one-time CT scan that assesses both blood vessels. METHODS: We prospectively enrolled 101 cases of CT angiography in patients with suspected pulmonary embolism or aortic dissection from our center between 2018 and 2020. We also retrospectively collected the data of 40 patients who underwent traditional two-time CT scans between 2015 and 2018. Patients were divided into four groups: test bolus (TB) I, TB II, bolus-tracking (BT) I, and BT II. The enhancement of the PA and aorta, and the radiation doses used in the four groups were collected. Those who underwent two-time scans were classified into the traditional PA or aorta scan groups. Data were compared between the BT and traditional groups. RESULTS: The aortic enhancement was highest in BT II (294.78 ± 64.48 HU) followed BT I (285.18 ± 64.99 HU), TB II (186.58 ± 57.53 HU), and TB I (173.62 ± 69.70 HU). The radiation dose used was lowest in BT I (11.85 ± 5.55 mSv) and BT II (9.07 ± 3.44 mSv) compared with that used in the traditional groups (20.07 ± 7.78 mSv) and accounted for half of the traditional group (45.17–59.02%). The aortic enhancement was also highest in BT II (294.78 ± 64.48 HU) followed by BT I (285.18 ± 64.99 HU) when compared with that in the traditional aorta scan group (234.95 ± 94.18 HU). CONCLUSION: Our CT protocol with a BT technique allows for a lower radiation dose and better image quality of the PA and aorta than those obtained using traditional CT scans. Trial registration: NCT04832633, retrospectively registered in April 2021 to the clinical trial registry. |
format | Online Article Text |
id | pubmed-8557493 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-85574932021-11-01 A practical biphasic contrast media injection protocol strongly enhances the aorta and pulmonary artery simultaneously using a single CT angiography scan Hsieh, Cheng-Chih Zeng, An-Bang Chen, Chia-Hung Jhou, Zong-Yi Wang, Chih-Hsin Yang, Ya-Ling Hsieh, Feng-Chuan Lin, Jing-Kai Yeh, Ju-Yen Huang, Chun-Chao BMC Med Imaging Technical Advance BACKGROUND: Enhancement profiles of the pulmonary artery (PA) and aorta differ when using computed tomography (CT) angiography. Our aim was to determine the optimal CT protocol for a one-time CT scan that assesses both blood vessels. METHODS: We prospectively enrolled 101 cases of CT angiography in patients with suspected pulmonary embolism or aortic dissection from our center between 2018 and 2020. We also retrospectively collected the data of 40 patients who underwent traditional two-time CT scans between 2015 and 2018. Patients were divided into four groups: test bolus (TB) I, TB II, bolus-tracking (BT) I, and BT II. The enhancement of the PA and aorta, and the radiation doses used in the four groups were collected. Those who underwent two-time scans were classified into the traditional PA or aorta scan groups. Data were compared between the BT and traditional groups. RESULTS: The aortic enhancement was highest in BT II (294.78 ± 64.48 HU) followed BT I (285.18 ± 64.99 HU), TB II (186.58 ± 57.53 HU), and TB I (173.62 ± 69.70 HU). The radiation dose used was lowest in BT I (11.85 ± 5.55 mSv) and BT II (9.07 ± 3.44 mSv) compared with that used in the traditional groups (20.07 ± 7.78 mSv) and accounted for half of the traditional group (45.17–59.02%). The aortic enhancement was also highest in BT II (294.78 ± 64.48 HU) followed by BT I (285.18 ± 64.99 HU) when compared with that in the traditional aorta scan group (234.95 ± 94.18 HU). CONCLUSION: Our CT protocol with a BT technique allows for a lower radiation dose and better image quality of the PA and aorta than those obtained using traditional CT scans. Trial registration: NCT04832633, retrospectively registered in April 2021 to the clinical trial registry. BioMed Central 2021-10-30 /pmc/articles/PMC8557493/ /pubmed/34717585 http://dx.doi.org/10.1186/s12880-021-00691-4 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Technical Advance Hsieh, Cheng-Chih Zeng, An-Bang Chen, Chia-Hung Jhou, Zong-Yi Wang, Chih-Hsin Yang, Ya-Ling Hsieh, Feng-Chuan Lin, Jing-Kai Yeh, Ju-Yen Huang, Chun-Chao A practical biphasic contrast media injection protocol strongly enhances the aorta and pulmonary artery simultaneously using a single CT angiography scan |
title | A practical biphasic contrast media injection protocol strongly enhances the aorta and pulmonary artery simultaneously using a single CT angiography scan |
title_full | A practical biphasic contrast media injection protocol strongly enhances the aorta and pulmonary artery simultaneously using a single CT angiography scan |
title_fullStr | A practical biphasic contrast media injection protocol strongly enhances the aorta and pulmonary artery simultaneously using a single CT angiography scan |
title_full_unstemmed | A practical biphasic contrast media injection protocol strongly enhances the aorta and pulmonary artery simultaneously using a single CT angiography scan |
title_short | A practical biphasic contrast media injection protocol strongly enhances the aorta and pulmonary artery simultaneously using a single CT angiography scan |
title_sort | practical biphasic contrast media injection protocol strongly enhances the aorta and pulmonary artery simultaneously using a single ct angiography scan |
topic | Technical Advance |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8557493/ https://www.ncbi.nlm.nih.gov/pubmed/34717585 http://dx.doi.org/10.1186/s12880-021-00691-4 |
work_keys_str_mv | AT hsiehchengchih apracticalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT zenganbang apracticalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT chenchiahung apracticalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT jhouzongyi apracticalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT wangchihhsin apracticalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT yangyaling apracticalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT hsiehfengchuan apracticalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT linjingkai apracticalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT yehjuyen apracticalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT huangchunchao apracticalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT hsiehchengchih practicalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT zenganbang practicalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT chenchiahung practicalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT jhouzongyi practicalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT wangchihhsin practicalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT yangyaling practicalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT hsiehfengchuan practicalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT linjingkai practicalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT yehjuyen practicalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan AT huangchunchao practicalbiphasiccontrastmediainjectionprotocolstronglyenhancestheaortaandpulmonaryarterysimultaneouslyusingasinglectangiographyscan |