Cargando…

The effect of thermo-mechanical fatigue on the retentive force and dimensional changes in polyetheretherketone clasps with different thickness and undercut

PURPOSE: Esthetic expectations have increased the use of polyetheretherketone (PEEK) clasps as alternatives to Cr-Co in removable partial dentures (RPDs). The objective of this study was to evaluate the retentive force and dimensional change of clasps with different thickness and undercut made from...

Descripción completa

Detalles Bibliográficos
Autores principales: Güleryüz, Ayşegül, Korkmaz, Cumhur, Şener, Ayşe, Taş, Mehmet Ozan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8558577/
https://www.ncbi.nlm.nih.gov/pubmed/34777720
http://dx.doi.org/10.4047/jap.2021.13.5.304
_version_ 1784592594907430912
author Güleryüz, Ayşegül
Korkmaz, Cumhur
Şener, Ayşe
Taş, Mehmet Ozan
author_facet Güleryüz, Ayşegül
Korkmaz, Cumhur
Şener, Ayşe
Taş, Mehmet Ozan
author_sort Güleryüz, Ayşegül
collection PubMed
description PURPOSE: Esthetic expectations have increased the use of polyetheretherketone (PEEK) clasps as alternatives to Cr-Co in removable partial dentures (RPDs). The objective of this study was to evaluate the retentive force and dimensional change of clasps with different thickness and undercut made from PEEK by the thermo-mechanical fatigue. MATERIALS AND METHODS: PEEK clasps (N = 48) with thicknesses of 1 or 1.50 mm and 48 premolar monolithic zirconia crowns with undercuts of 0.25 mm or 0.50 mm were fabricated. Samples are divided into four groups (C1-C4) and were subjected to 7200 thermal aging cycles (at 5 - 55℃). The changes in the retentive force and dimensions of the clasps were measured by micro-stress testing and micro-CT devices from five measurement points (M1 - M5). One-way ANOVA, paired t-test, two-way repeated ANOVA, and post-hoc tests were used to analyze the data (P < .05). RESULTS: The retentive forces of C1, C2, C3, and C4 groups in initial and final test were found to be 4.389-3.388 N, 4.67 - 3.396 N, 5.161 - 4.096 N, 5.459 - 4.141 N, respectively. The effects of retentive force of all PEEK clasps groups were significant decreased. Thermo-mechanical cycles caused significant dimensional changes at points with M2, M4, and M5, and abraded the clasp corners and increased the distance between the ends of the clasp, resulting in reduced retentive forces (P(*) = .016, P(*) = .042, P < .001, respectively). CONCLUSION: Thermo-mechanical aging decreases the retentive forces in PEEK clasps. Increasing the thickness and undercut amount of clasps decreases the amount of dimensional change. The values measured after aging are within the clinically acceptable limits.
format Online
Article
Text
id pubmed-8558577
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-85585772021-11-12 The effect of thermo-mechanical fatigue on the retentive force and dimensional changes in polyetheretherketone clasps with different thickness and undercut Güleryüz, Ayşegül Korkmaz, Cumhur Şener, Ayşe Taş, Mehmet Ozan J Adv Prosthodont Original Article PURPOSE: Esthetic expectations have increased the use of polyetheretherketone (PEEK) clasps as alternatives to Cr-Co in removable partial dentures (RPDs). The objective of this study was to evaluate the retentive force and dimensional change of clasps with different thickness and undercut made from PEEK by the thermo-mechanical fatigue. MATERIALS AND METHODS: PEEK clasps (N = 48) with thicknesses of 1 or 1.50 mm and 48 premolar monolithic zirconia crowns with undercuts of 0.25 mm or 0.50 mm were fabricated. Samples are divided into four groups (C1-C4) and were subjected to 7200 thermal aging cycles (at 5 - 55℃). The changes in the retentive force and dimensions of the clasps were measured by micro-stress testing and micro-CT devices from five measurement points (M1 - M5). One-way ANOVA, paired t-test, two-way repeated ANOVA, and post-hoc tests were used to analyze the data (P < .05). RESULTS: The retentive forces of C1, C2, C3, and C4 groups in initial and final test were found to be 4.389-3.388 N, 4.67 - 3.396 N, 5.161 - 4.096 N, 5.459 - 4.141 N, respectively. The effects of retentive force of all PEEK clasps groups were significant decreased. Thermo-mechanical cycles caused significant dimensional changes at points with M2, M4, and M5, and abraded the clasp corners and increased the distance between the ends of the clasp, resulting in reduced retentive forces (P(*) = .016, P(*) = .042, P < .001, respectively). CONCLUSION: Thermo-mechanical aging decreases the retentive forces in PEEK clasps. Increasing the thickness and undercut amount of clasps decreases the amount of dimensional change. The values measured after aging are within the clinically acceptable limits. The Korean Academy of Prosthodontics 2021-10 2021-10-27 /pmc/articles/PMC8558577/ /pubmed/34777720 http://dx.doi.org/10.4047/jap.2021.13.5.304 Text en © 2021 The Korean Academy of Prosthodontics https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Güleryüz, Ayşegül
Korkmaz, Cumhur
Şener, Ayşe
Taş, Mehmet Ozan
The effect of thermo-mechanical fatigue on the retentive force and dimensional changes in polyetheretherketone clasps with different thickness and undercut
title The effect of thermo-mechanical fatigue on the retentive force and dimensional changes in polyetheretherketone clasps with different thickness and undercut
title_full The effect of thermo-mechanical fatigue on the retentive force and dimensional changes in polyetheretherketone clasps with different thickness and undercut
title_fullStr The effect of thermo-mechanical fatigue on the retentive force and dimensional changes in polyetheretherketone clasps with different thickness and undercut
title_full_unstemmed The effect of thermo-mechanical fatigue on the retentive force and dimensional changes in polyetheretherketone clasps with different thickness and undercut
title_short The effect of thermo-mechanical fatigue on the retentive force and dimensional changes in polyetheretherketone clasps with different thickness and undercut
title_sort effect of thermo-mechanical fatigue on the retentive force and dimensional changes in polyetheretherketone clasps with different thickness and undercut
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8558577/
https://www.ncbi.nlm.nih.gov/pubmed/34777720
http://dx.doi.org/10.4047/jap.2021.13.5.304
work_keys_str_mv AT guleryuzaysegul theeffectofthermomechanicalfatigueontheretentiveforceanddimensionalchangesinpolyetheretherketoneclaspswithdifferentthicknessandundercut
AT korkmazcumhur theeffectofthermomechanicalfatigueontheretentiveforceanddimensionalchangesinpolyetheretherketoneclaspswithdifferentthicknessandundercut
AT senerayse theeffectofthermomechanicalfatigueontheretentiveforceanddimensionalchangesinpolyetheretherketoneclaspswithdifferentthicknessandundercut
AT tasmehmetozan theeffectofthermomechanicalfatigueontheretentiveforceanddimensionalchangesinpolyetheretherketoneclaspswithdifferentthicknessandundercut
AT guleryuzaysegul effectofthermomechanicalfatigueontheretentiveforceanddimensionalchangesinpolyetheretherketoneclaspswithdifferentthicknessandundercut
AT korkmazcumhur effectofthermomechanicalfatigueontheretentiveforceanddimensionalchangesinpolyetheretherketoneclaspswithdifferentthicknessandundercut
AT senerayse effectofthermomechanicalfatigueontheretentiveforceanddimensionalchangesinpolyetheretherketoneclaspswithdifferentthicknessandundercut
AT tasmehmetozan effectofthermomechanicalfatigueontheretentiveforceanddimensionalchangesinpolyetheretherketoneclaspswithdifferentthicknessandundercut