Cargando…
Mechanical Analysis after Proximal Femoral Reinforcement with Polymethylmethacrylate in Alternated Double Holes
Objective To evaluate, through a biomechanical assay, the maximum load, energy, and displacement necessary for the occurrence of fractures in synthetic models of femurs after the removal of cannulated screws and the performance of a reinforcement technique with polymethylmethacrylate (PMMA) in diff...
Autores principales: | Freitas, Anderson, Lessa, Mariana de Medeiros, de Oliveira, Saulo Pereira, Oliveira, Pedro Félix Pereira de, Giordano, Vincenzo, Shimano, Antônio Carlos |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Thieme Revinter Publicações Ltda.
2020
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8558925/ https://www.ncbi.nlm.nih.gov/pubmed/34733437 http://dx.doi.org/10.1055/s-0040-1714221 |
Ejemplares similares
-
PRELIMINARY MECHANICAL TEST OF PROXIMAL FEMUR REINFORCEMENT WITH CEMENTED X-SHAPED PMMA
por: Freitas, Anderson, et al.
Publicado: (2018) -
Nanoclay-reinforced polymethylmethacrylate and its mechanical properties
por: Barzegar, Ali, et al.
Publicado: (2018) -
Anatomical description of the proximal third
of the medial femoral circumflex artery. A cadaveric study
por: Freitas, Anderson, et al.
Publicado: (2012) -
Proximal Femur Endoprosthesis Augmentation with Polymethylmethacrylate and Condylar Plate: A Case Series
por: Gaitán-Lee, Hernando, et al.
Publicado: (2023) -
Evaluation of a Locking Autocompression Screw Model in Pauwels Type-3 Femoral Neck Fracture: In Vitro Analysis
por: Giordano, Vincenzo, et al.
Publicado: (2022)