Impact of intestinal ultrasound with a portable system in the management of Crohn’s disease
BACKGROUND: Intestinal ultrasound (IUS) is a valid cross-sectional imaging technique for the evaluation of Crohn’s disease (CD). With advancements in technology, portable ultrasound systems are becoming widely available, and the inevitable change to their use by non-radiologist clinicians would be a...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8560037/ https://www.ncbi.nlm.nih.gov/pubmed/34733527 http://dx.doi.org/10.1093/gastro/goaa088 |
_version_ | 1784592865001734144 |
---|---|
author | Gonen, Can Surmelioglu, Ali Kochan, Koray Ozer, Serhat Aslan, Ekrem Tilki, Metin |
author_facet | Gonen, Can Surmelioglu, Ali Kochan, Koray Ozer, Serhat Aslan, Ekrem Tilki, Metin |
author_sort | Gonen, Can |
collection | PubMed |
description | BACKGROUND: Intestinal ultrasound (IUS) is a valid cross-sectional imaging technique for the evaluation of Crohn’s disease (CD). With advancements in technology, portable ultrasound systems are becoming widely available, and the inevitable change to their use by non-radiologist clinicians would be a valuable contribution to improving patient care. This study aimed to investigate the diagnostic yield of IUS examination performed by a gastroenterologist with a portable system as an adjunct imaging modality in the routine care of CD patients. METHODS: A total of 117 CD patients were assessed by IUS imaging. Pre- and post-IUS clinical-management decisions were recorded. The primary outcome was to evaluate the change in the patients’ clinical-management decision following the IUS examination. The diagnostic accuracy was compared against the reference decision reached via a multidisiplinary meeting after the evaluation of all patient-related data. The endoscopic disease activity was determined using the simple endoscopic score for Crohn's disease (SES-CD). RESULTS: The initial clinical-management decision was changed in 47 patients (40.2%) after the IUS examination (P = 0.001). The accuracy of patient-management decisions improved from 63.2% to 90.6% in comparison to reference decisions (P < 0.001). After IUS examination, a further 13 cases (11.1%) were identified for urgent surgical/interventional procedures. The accuracy of colonoscopic (SES-CD ≥3) assessment was shown to be comparable to that of IUS (94% vs 91%). The sensitivity for disease presence was 95% with colonoscopy and 94% with the IUS assessment. CONCLUSION: IUS examination with the use of a portable ultrasonography system significantly improves clinical-management decisions. With further supporting data, this practice would possibly become a requirement for CD management. |
format | Online Article Text |
id | pubmed-8560037 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-85600372021-11-02 Impact of intestinal ultrasound with a portable system in the management of Crohn’s disease Gonen, Can Surmelioglu, Ali Kochan, Koray Ozer, Serhat Aslan, Ekrem Tilki, Metin Gastroenterol Rep (Oxf) Original Articles BACKGROUND: Intestinal ultrasound (IUS) is a valid cross-sectional imaging technique for the evaluation of Crohn’s disease (CD). With advancements in technology, portable ultrasound systems are becoming widely available, and the inevitable change to their use by non-radiologist clinicians would be a valuable contribution to improving patient care. This study aimed to investigate the diagnostic yield of IUS examination performed by a gastroenterologist with a portable system as an adjunct imaging modality in the routine care of CD patients. METHODS: A total of 117 CD patients were assessed by IUS imaging. Pre- and post-IUS clinical-management decisions were recorded. The primary outcome was to evaluate the change in the patients’ clinical-management decision following the IUS examination. The diagnostic accuracy was compared against the reference decision reached via a multidisiplinary meeting after the evaluation of all patient-related data. The endoscopic disease activity was determined using the simple endoscopic score for Crohn's disease (SES-CD). RESULTS: The initial clinical-management decision was changed in 47 patients (40.2%) after the IUS examination (P = 0.001). The accuracy of patient-management decisions improved from 63.2% to 90.6% in comparison to reference decisions (P < 0.001). After IUS examination, a further 13 cases (11.1%) were identified for urgent surgical/interventional procedures. The accuracy of colonoscopic (SES-CD ≥3) assessment was shown to be comparable to that of IUS (94% vs 91%). The sensitivity for disease presence was 95% with colonoscopy and 94% with the IUS assessment. CONCLUSION: IUS examination with the use of a portable ultrasonography system significantly improves clinical-management decisions. With further supporting data, this practice would possibly become a requirement for CD management. Oxford University Press 2020-12-10 /pmc/articles/PMC8560037/ /pubmed/34733527 http://dx.doi.org/10.1093/gastro/goaa088 Text en © The Author(s) 2020. Published by Oxford University Press and Sixth Affiliated Hospital of Sun Yat-sen University https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Original Articles Gonen, Can Surmelioglu, Ali Kochan, Koray Ozer, Serhat Aslan, Ekrem Tilki, Metin Impact of intestinal ultrasound with a portable system in the management of Crohn’s disease |
title | Impact of intestinal ultrasound with a portable system in the management of Crohn’s disease |
title_full | Impact of intestinal ultrasound with a portable system in the management of Crohn’s disease |
title_fullStr | Impact of intestinal ultrasound with a portable system in the management of Crohn’s disease |
title_full_unstemmed | Impact of intestinal ultrasound with a portable system in the management of Crohn’s disease |
title_short | Impact of intestinal ultrasound with a portable system in the management of Crohn’s disease |
title_sort | impact of intestinal ultrasound with a portable system in the management of crohn’s disease |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8560037/ https://www.ncbi.nlm.nih.gov/pubmed/34733527 http://dx.doi.org/10.1093/gastro/goaa088 |
work_keys_str_mv | AT gonencan impactofintestinalultrasoundwithaportablesysteminthemanagementofcrohnsdisease AT surmeliogluali impactofintestinalultrasoundwithaportablesysteminthemanagementofcrohnsdisease AT kochankoray impactofintestinalultrasoundwithaportablesysteminthemanagementofcrohnsdisease AT ozerserhat impactofintestinalultrasoundwithaportablesysteminthemanagementofcrohnsdisease AT aslanekrem impactofintestinalultrasoundwithaportablesysteminthemanagementofcrohnsdisease AT tilkimetin impactofintestinalultrasoundwithaportablesysteminthemanagementofcrohnsdisease |