Cargando…

Safety and Effectiveness of F-18 Fluoroestradiol Positron Emission Tomography/Computed Tomography: a Systematic Review and Meta-analysis

BACKGROUND: We conducted a pooled analysis of the diagnostic accuracy of F-18 fluoroestradiol (F-18 FES) positron emission tomography/computed tomography (PET/CT) assessing estrogen receptor expression of patients who have recurrent or metastatic breast cancer. METHODS: Two investigators and seven r...

Descripción completa

Detalles Bibliográficos
Autor principal: Mo, Jin A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Medical Sciences 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8560320/
https://www.ncbi.nlm.nih.gov/pubmed/34725978
http://dx.doi.org/10.3346/jkms.2021.36.e271
_version_ 1784592919479451648
author Mo, Jin A
author_facet Mo, Jin A
author_sort Mo, Jin A
collection PubMed
description BACKGROUND: We conducted a pooled analysis of the diagnostic accuracy of F-18 fluoroestradiol (F-18 FES) positron emission tomography/computed tomography (PET/CT) assessing estrogen receptor expression of patients who have recurrent or metastatic breast cancer. METHODS: Two investigators and seven related experts (from the departments of nuclear medicine, hematological oncology, surgery, and evidence-based medicine) evaluated the effectiveness of F-18 FES PET/CT according to diagnostic accuracy and correlation with immunohistochemistry tests via systematic literature review, and safety according to test-related side effects. The present study was conducted in accordance with the Scottish Intercollegiate Guidelines (SIGN), and the Cochrane, and Preferred Reporting Items for Systematic Reviews and Meta Analyses guidelines. The SIGN tools were used for quality assessment. RESULTS: Of the 512 articles retrieved in the literature search, 8 were deemed to be eligible for inclusion. Results of the evaluation indicated that the F-18 FES PET/CT test was safe because patients who reported pain in the injection site in the analyzed articles are most likely to be caused by mechanical injury from needle injection not by administration of radioactive materials. Assessment of diagnostic accuracy based on data from seven studies revealed a pooled sensitivity and specificity of 0.86 and 0.85, respectively. CONCLUSION: As such, the test was evaluated to be a safe and effective and, considering the anatomical site where only invasive tests are possible, the test was deemed to have high clinical utility.
format Online
Article
Text
id pubmed-8560320
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Korean Academy of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-85603202021-11-12 Safety and Effectiveness of F-18 Fluoroestradiol Positron Emission Tomography/Computed Tomography: a Systematic Review and Meta-analysis Mo, Jin A J Korean Med Sci Original Article BACKGROUND: We conducted a pooled analysis of the diagnostic accuracy of F-18 fluoroestradiol (F-18 FES) positron emission tomography/computed tomography (PET/CT) assessing estrogen receptor expression of patients who have recurrent or metastatic breast cancer. METHODS: Two investigators and seven related experts (from the departments of nuclear medicine, hematological oncology, surgery, and evidence-based medicine) evaluated the effectiveness of F-18 FES PET/CT according to diagnostic accuracy and correlation with immunohistochemistry tests via systematic literature review, and safety according to test-related side effects. The present study was conducted in accordance with the Scottish Intercollegiate Guidelines (SIGN), and the Cochrane, and Preferred Reporting Items for Systematic Reviews and Meta Analyses guidelines. The SIGN tools were used for quality assessment. RESULTS: Of the 512 articles retrieved in the literature search, 8 were deemed to be eligible for inclusion. Results of the evaluation indicated that the F-18 FES PET/CT test was safe because patients who reported pain in the injection site in the analyzed articles are most likely to be caused by mechanical injury from needle injection not by administration of radioactive materials. Assessment of diagnostic accuracy based on data from seven studies revealed a pooled sensitivity and specificity of 0.86 and 0.85, respectively. CONCLUSION: As such, the test was evaluated to be a safe and effective and, considering the anatomical site where only invasive tests are possible, the test was deemed to have high clinical utility. The Korean Academy of Medical Sciences 2021-09-23 /pmc/articles/PMC8560320/ /pubmed/34725978 http://dx.doi.org/10.3346/jkms.2021.36.e271 Text en © 2021 The Korean Academy of Medical Sciences. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Mo, Jin A
Safety and Effectiveness of F-18 Fluoroestradiol Positron Emission Tomography/Computed Tomography: a Systematic Review and Meta-analysis
title Safety and Effectiveness of F-18 Fluoroestradiol Positron Emission Tomography/Computed Tomography: a Systematic Review and Meta-analysis
title_full Safety and Effectiveness of F-18 Fluoroestradiol Positron Emission Tomography/Computed Tomography: a Systematic Review and Meta-analysis
title_fullStr Safety and Effectiveness of F-18 Fluoroestradiol Positron Emission Tomography/Computed Tomography: a Systematic Review and Meta-analysis
title_full_unstemmed Safety and Effectiveness of F-18 Fluoroestradiol Positron Emission Tomography/Computed Tomography: a Systematic Review and Meta-analysis
title_short Safety and Effectiveness of F-18 Fluoroestradiol Positron Emission Tomography/Computed Tomography: a Systematic Review and Meta-analysis
title_sort safety and effectiveness of f-18 fluoroestradiol positron emission tomography/computed tomography: a systematic review and meta-analysis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8560320/
https://www.ncbi.nlm.nih.gov/pubmed/34725978
http://dx.doi.org/10.3346/jkms.2021.36.e271
work_keys_str_mv AT mojina safetyandeffectivenessoff18fluoroestradiolpositronemissiontomographycomputedtomographyasystematicreviewandmetaanalysis