Cargando…
Impact of Screw Diameter and Length on Pedicle Screw Fixation Strength in Osteoporotic Vertebrae: A Finite Element Analysis
STUDY DESIGN: Biomechanical study. PURPOSE: To quantitatively investigate the effect of screw size on screw fixation in osteoporotic vertebrae with finite element analysis (FEA) OVERVIEW OF LITERATURE: Osteoporosis poses a challenge in spinal instrumentation; however, the selection of screw size is...
Autores principales: | Matsukawa, Keitaro, Yato, Yoshiyuki, Imabayashi, Hideaki |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Spine Surgery
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8561163/ https://www.ncbi.nlm.nih.gov/pubmed/33355846 http://dx.doi.org/10.31616/asj.2020.0353 |
Ejemplares similares
-
Identification of Pedicle Screw Pullout Load Paths for Osteoporotic Vertebrae
por: Krishnan, Venkatesh, et al.
Publicado: (2020) -
Lumbar pedicle screw fixation with cortical bone trajectory: A review from anatomical and biomechanical standpoints
por: Matsukawa, Keitaro, et al.
Publicado: (2017) -
Correlation between the Computed Tomography Values of the Screw Path and Pedicle Screw Pullout Strength: An Experimental Study in Porcine Vertebrae
por: Ikeura, Atsushi, et al.
Publicado: (2020) -
Designs and Techniques That Improve the Pullout Strength of Pedicle Screws in Osteoporotic Vertebrae: Current Status
por: Shea, Thomas M., et al.
Publicado: (2014) -
Pull-out strength of cemented solid versus fenestrated pedicle screws in osteoporotic vertebrae
por: Leichtle, C. I., et al.
Publicado: (2016)