Allergic contact dermatitis to rubber accelerators in protective gloves: Problems, challenges, and solutions for occupational skin protection
Protective gloves are an elementary component of personal protective equipment in many occupations and are intended to protect the hands from various hazards (e.g., wetness, chemicals, mechanical forces, or thermal stress). This is particularly important when other occupational safety measures (e.g....
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dustri-Verlag Dr. Karl Feistle
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8561832/ https://www.ncbi.nlm.nih.gov/pubmed/34734158 http://dx.doi.org/10.5414/ALX02265E |
_version_ | 1784593151815581696 |
---|---|
author | Hansen, Andreas Brans, Richard Sonsmann, Flora |
author_facet | Hansen, Andreas Brans, Richard Sonsmann, Flora |
author_sort | Hansen, Andreas |
collection | PubMed |
description | Protective gloves are an elementary component of personal protective equipment in many occupations and are intended to protect the hands from various hazards (e.g., wetness, chemicals, mechanical forces, or thermal stress). This is particularly important when other occupational safety measures (e.g., technical-organizational measures) cannot be implemented or are insufficient. However, it is not uncommon for protective gloves themselves to become a problem, as some of their ingredients (e.g., rubber accelerators) can cause allergic reactions. Accelerators in rubber gloves include thiurams, dithiocarbamates, thiazoles, guanidines, and thioureas. If no alternative means of protection are available, this may even result in abandoning the profession. This article is about rubber accelerators, which are often contained in protective gloves made of different rubber materials (e.g., natural rubber (latex) and nitrile rubber) and may cause delayed-type allergies, as well as related challenges, problems, and solutions for occupational skin protection. |
format | Online Article Text |
id | pubmed-8561832 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Dustri-Verlag Dr. Karl Feistle |
record_format | MEDLINE/PubMed |
spelling | pubmed-85618322021-11-02 Allergic contact dermatitis to rubber accelerators in protective gloves: Problems, challenges, and solutions for occupational skin protection Hansen, Andreas Brans, Richard Sonsmann, Flora Allergol Select Review Article Protective gloves are an elementary component of personal protective equipment in many occupations and are intended to protect the hands from various hazards (e.g., wetness, chemicals, mechanical forces, or thermal stress). This is particularly important when other occupational safety measures (e.g., technical-organizational measures) cannot be implemented or are insufficient. However, it is not uncommon for protective gloves themselves to become a problem, as some of their ingredients (e.g., rubber accelerators) can cause allergic reactions. Accelerators in rubber gloves include thiurams, dithiocarbamates, thiazoles, guanidines, and thioureas. If no alternative means of protection are available, this may even result in abandoning the profession. This article is about rubber accelerators, which are often contained in protective gloves made of different rubber materials (e.g., natural rubber (latex) and nitrile rubber) and may cause delayed-type allergies, as well as related challenges, problems, and solutions for occupational skin protection. Dustri-Verlag Dr. Karl Feistle 2021-10-22 /pmc/articles/PMC8561832/ /pubmed/34734158 http://dx.doi.org/10.5414/ALX02265E Text en © Dustri-Verlag Dr. K. Feistle https://creativecommons.org/licenses/by/2.5/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Article Hansen, Andreas Brans, Richard Sonsmann, Flora Allergic contact dermatitis to rubber accelerators in protective gloves: Problems, challenges, and solutions for occupational skin protection |
title | Allergic contact dermatitis to rubber accelerators in protective gloves: Problems, challenges, and solutions for occupational skin protection |
title_full | Allergic contact dermatitis to rubber accelerators in protective gloves: Problems, challenges, and solutions for occupational skin protection |
title_fullStr | Allergic contact dermatitis to rubber accelerators in protective gloves: Problems, challenges, and solutions for occupational skin protection |
title_full_unstemmed | Allergic contact dermatitis to rubber accelerators in protective gloves: Problems, challenges, and solutions for occupational skin protection |
title_short | Allergic contact dermatitis to rubber accelerators in protective gloves: Problems, challenges, and solutions for occupational skin protection |
title_sort | allergic contact dermatitis to rubber accelerators in protective gloves: problems, challenges, and solutions for occupational skin protection |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8561832/ https://www.ncbi.nlm.nih.gov/pubmed/34734158 http://dx.doi.org/10.5414/ALX02265E |
work_keys_str_mv | AT hansenandreas allergiccontactdermatitistorubberacceleratorsinprotectiveglovesproblemschallengesandsolutionsforoccupationalskinprotection AT bransrichard allergiccontactdermatitistorubberacceleratorsinprotectiveglovesproblemschallengesandsolutionsforoccupationalskinprotection AT sonsmannflora allergiccontactdermatitistorubberacceleratorsinprotectiveglovesproblemschallengesandsolutionsforoccupationalskinprotection |