The study of distance changes between lumbar bi-cortical pedicle screws and anterior large vessels in patients with lumbar spondylolisthesis
OBJECTIVE: This paper was a anatomical radiographic study of distance between lumbar bi-cortical pedicle screws (BPSs) and anterior large vessels (ALVs) in patients with lumbar spondylolisthesis, and to provide clinical basis for evaluating the safety of bi-cortical pedicle screw implantation during...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8561981/ https://www.ncbi.nlm.nih.gov/pubmed/34724945 http://dx.doi.org/10.1186/s12891-021-04811-7 |
_version_ | 1784593177800343552 |
---|---|
author | Zhao, Li Wan, Chenguang Han, Shuhong Li, Baofeng Zheng, Shaoyi |
author_facet | Zhao, Li Wan, Chenguang Han, Shuhong Li, Baofeng Zheng, Shaoyi |
author_sort | Zhao, Li |
collection | PubMed |
description | OBJECTIVE: This paper was a anatomical radiographic study of distance between lumbar bi-cortical pedicle screws (BPSs) and anterior large vessels (ALVs) in patients with lumbar spondylolisthesis, and to provide clinical basis for evaluating the safety of bi-cortical pedicle screw implantation during lumbar spondylolisthesis. METHODS: Complete Computed tomography (CT) data of 104 patients with grade I lumbar spondylolisthesis (L4 52 and L5 52) and 107 non-spondylolisthesis patients (control group) were collected in this study. The distances between lumbar 4,5(L4,5) and sacrum 1(S1) BPSs and ALVs (abdominal aorta, inferior vena cava, left and right common iliac artery, internal and external iliac artery) were respectively measured at different transverse screw angles (TSAs) (L4:5°,10°; L5:10°,15°; S1:0°,5°,10°) and analyzed by SPSS (v25.0). There were three types of distances from the anterior vertebral cortex (AVC) to the ALVs (D(AVC-ALV)): D(AVC-ALV) N, D(AVC-ALV) ≥ 0.50 cm, and D(AVC-ALV) < 0.50 cm; these different distances represented non-contact, distant and close ALV respectively. RESULTS: We calculated the incidences of screw tip contacting large vessels at different TSAs and provided the appropriate angle of screw implantation. In non-spondylolisthesis group, in L4, the appropriate left TSA was 5°, and the incidence of the close ALV was 4.62%. In S1, the appropriate left TSA was 0° and the incidence of the close ALV was 22.4%, while the appropriate right TSA was 10° and the incidence of the close ALV was 17.8%. In L4 spondylolisthesis group, in L4, the appropriate left TSA was 5°, and the incidence of the close ALV was 3.8%. In L5 spondylolisthesis group, in S1, the appropriate left TSA was 0° and the incidence of the close ALV was 19.2%, while the appropriate right TSA was 10° and the incidence of the close ALV was 21.2%. The use of BPS was not appropriate on the right side of L4 or on the either side of L5 both in spondylolisthesis and control group. In patients with lumbar 4 spondylolisthesis, the incidences of screw tip contacting large vessels were less than the control group in both L4 and 5. In patients with lumbar 5 spondylolisthesis, the incidences of screw tip contacting large vessels were less than the control group in L5, while there were no significant difference in S1. CONCLUSION: It is very important that considering the anatomical relationship between the AVC and the ALVs while planning BPSs. The use of BPS does not apply to every lumbar vertebra. In patients with lumbar spondylolisthesis and non-spondylolisthesis patients, the incidences of screw tip contacting large vessels are different. |
format | Online Article Text |
id | pubmed-8561981 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-85619812021-11-03 The study of distance changes between lumbar bi-cortical pedicle screws and anterior large vessels in patients with lumbar spondylolisthesis Zhao, Li Wan, Chenguang Han, Shuhong Li, Baofeng Zheng, Shaoyi BMC Musculoskelet Disord Research OBJECTIVE: This paper was a anatomical radiographic study of distance between lumbar bi-cortical pedicle screws (BPSs) and anterior large vessels (ALVs) in patients with lumbar spondylolisthesis, and to provide clinical basis for evaluating the safety of bi-cortical pedicle screw implantation during lumbar spondylolisthesis. METHODS: Complete Computed tomography (CT) data of 104 patients with grade I lumbar spondylolisthesis (L4 52 and L5 52) and 107 non-spondylolisthesis patients (control group) were collected in this study. The distances between lumbar 4,5(L4,5) and sacrum 1(S1) BPSs and ALVs (abdominal aorta, inferior vena cava, left and right common iliac artery, internal and external iliac artery) were respectively measured at different transverse screw angles (TSAs) (L4:5°,10°; L5:10°,15°; S1:0°,5°,10°) and analyzed by SPSS (v25.0). There were three types of distances from the anterior vertebral cortex (AVC) to the ALVs (D(AVC-ALV)): D(AVC-ALV) N, D(AVC-ALV) ≥ 0.50 cm, and D(AVC-ALV) < 0.50 cm; these different distances represented non-contact, distant and close ALV respectively. RESULTS: We calculated the incidences of screw tip contacting large vessels at different TSAs and provided the appropriate angle of screw implantation. In non-spondylolisthesis group, in L4, the appropriate left TSA was 5°, and the incidence of the close ALV was 4.62%. In S1, the appropriate left TSA was 0° and the incidence of the close ALV was 22.4%, while the appropriate right TSA was 10° and the incidence of the close ALV was 17.8%. In L4 spondylolisthesis group, in L4, the appropriate left TSA was 5°, and the incidence of the close ALV was 3.8%. In L5 spondylolisthesis group, in S1, the appropriate left TSA was 0° and the incidence of the close ALV was 19.2%, while the appropriate right TSA was 10° and the incidence of the close ALV was 21.2%. The use of BPS was not appropriate on the right side of L4 or on the either side of L5 both in spondylolisthesis and control group. In patients with lumbar 4 spondylolisthesis, the incidences of screw tip contacting large vessels were less than the control group in both L4 and 5. In patients with lumbar 5 spondylolisthesis, the incidences of screw tip contacting large vessels were less than the control group in L5, while there were no significant difference in S1. CONCLUSION: It is very important that considering the anatomical relationship between the AVC and the ALVs while planning BPSs. The use of BPS does not apply to every lumbar vertebra. In patients with lumbar spondylolisthesis and non-spondylolisthesis patients, the incidences of screw tip contacting large vessels are different. BioMed Central 2021-11-01 /pmc/articles/PMC8561981/ /pubmed/34724945 http://dx.doi.org/10.1186/s12891-021-04811-7 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Zhao, Li Wan, Chenguang Han, Shuhong Li, Baofeng Zheng, Shaoyi The study of distance changes between lumbar bi-cortical pedicle screws and anterior large vessels in patients with lumbar spondylolisthesis |
title | The study of distance changes between lumbar bi-cortical pedicle screws and anterior large vessels in patients with lumbar spondylolisthesis |
title_full | The study of distance changes between lumbar bi-cortical pedicle screws and anterior large vessels in patients with lumbar spondylolisthesis |
title_fullStr | The study of distance changes between lumbar bi-cortical pedicle screws and anterior large vessels in patients with lumbar spondylolisthesis |
title_full_unstemmed | The study of distance changes between lumbar bi-cortical pedicle screws and anterior large vessels in patients with lumbar spondylolisthesis |
title_short | The study of distance changes between lumbar bi-cortical pedicle screws and anterior large vessels in patients with lumbar spondylolisthesis |
title_sort | study of distance changes between lumbar bi-cortical pedicle screws and anterior large vessels in patients with lumbar spondylolisthesis |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8561981/ https://www.ncbi.nlm.nih.gov/pubmed/34724945 http://dx.doi.org/10.1186/s12891-021-04811-7 |
work_keys_str_mv | AT zhaoli thestudyofdistancechangesbetweenlumbarbicorticalpediclescrewsandanteriorlargevesselsinpatientswithlumbarspondylolisthesis AT wanchenguang thestudyofdistancechangesbetweenlumbarbicorticalpediclescrewsandanteriorlargevesselsinpatientswithlumbarspondylolisthesis AT hanshuhong thestudyofdistancechangesbetweenlumbarbicorticalpediclescrewsandanteriorlargevesselsinpatientswithlumbarspondylolisthesis AT libaofeng thestudyofdistancechangesbetweenlumbarbicorticalpediclescrewsandanteriorlargevesselsinpatientswithlumbarspondylolisthesis AT zhengshaoyi thestudyofdistancechangesbetweenlumbarbicorticalpediclescrewsandanteriorlargevesselsinpatientswithlumbarspondylolisthesis AT zhaoli studyofdistancechangesbetweenlumbarbicorticalpediclescrewsandanteriorlargevesselsinpatientswithlumbarspondylolisthesis AT wanchenguang studyofdistancechangesbetweenlumbarbicorticalpediclescrewsandanteriorlargevesselsinpatientswithlumbarspondylolisthesis AT hanshuhong studyofdistancechangesbetweenlumbarbicorticalpediclescrewsandanteriorlargevesselsinpatientswithlumbarspondylolisthesis AT libaofeng studyofdistancechangesbetweenlumbarbicorticalpediclescrewsandanteriorlargevesselsinpatientswithlumbarspondylolisthesis AT zhengshaoyi studyofdistancechangesbetweenlumbarbicorticalpediclescrewsandanteriorlargevesselsinpatientswithlumbarspondylolisthesis |