A new choice of stent for transjugular intrahepatic portosystemic shunt creation: Viabahn ePTFE covered stent/bare metal stent combination
OBJECTIVES: To compare the clinical outcomes in terms of structure and function between the insertion of a transjugular intrahepatic portosystemic shunt (TIPS) created with the Viabahn ePTFE covered stent/bare metal stent (BMS) combination and the Fluency ePTFE covered stent/BMS combination. METHODS...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
KeAi Publishing
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8562232/ https://www.ncbi.nlm.nih.gov/pubmed/34805945 http://dx.doi.org/10.1016/j.jimed.2020.10.003 |
_version_ | 1784593220434395136 |
---|---|
author | Liu, Jiacheng Meng, Jie Zhou, Chen Shi, Qin Yang, Chongtu Ma, Jinqiang Chen, Manman Xiong, Bin |
author_facet | Liu, Jiacheng Meng, Jie Zhou, Chen Shi, Qin Yang, Chongtu Ma, Jinqiang Chen, Manman Xiong, Bin |
author_sort | Liu, Jiacheng |
collection | PubMed |
description | OBJECTIVES: To compare the clinical outcomes in terms of structure and function between the insertion of a transjugular intrahepatic portosystemic shunt (TIPS) created with the Viabahn ePTFE covered stent/bare metal stent (BMS) combination and the Fluency ePTFE covered stent/BMS combination. METHODS: A total of 101 consecutive patients who received a TIPS from February 2016 to August 2018 in our center were retrospectively analyzed. Sixty-four subjects were enrolled in the Viabahn group and 37 were enrolled in the Fluency group. The geometry characteristics of the TIPS were calculated, and the associated occurrence of shunt dysfunction, survival, overt hepatic encephalopathy, and variceal rebleeding were evaluated. RESULTS: The technical success rate was 100%. After the insertion of the TIPS, the rate of shunt dysfunction during the first 3 months was significantly different between the Viabahn and Fluency groups (1.6% and 13.5%, respectively; p = 0.024). Multivariate analysis indicated that the angle of portal venous inflow (α) was the only independent risk factor for shunt dysfunction (hazard ratio = 1.060, 95% confidence interval = 1.009–1.112, p = 0.020). In addition, 3 months after the TIPS insertion, the α angle distinctly increased from 20.9° ± 14.3°–26.9° ± 20.1° (p = 0.005) in the Fluency group but did not change significantly in the Viabahn group (from 21.9° ± 15.1°–22.9° ± 17.6°, p = 0.798). CONCLUSIONS: Shunt dysfunction was related to the α angle owing to the slight effect on the α angle after the implantation of the TIPS. The Viabahn ePTFE covered stent/BMS combination was more stable in structure and promised higher short-term stent patency compared with the Fluency ePTFE covered stent/BMS combination. |
format | Online Article Text |
id | pubmed-8562232 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | KeAi Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-85622322021-11-19 A new choice of stent for transjugular intrahepatic portosystemic shunt creation: Viabahn ePTFE covered stent/bare metal stent combination Liu, Jiacheng Meng, Jie Zhou, Chen Shi, Qin Yang, Chongtu Ma, Jinqiang Chen, Manman Xiong, Bin J Interv Med Article OBJECTIVES: To compare the clinical outcomes in terms of structure and function between the insertion of a transjugular intrahepatic portosystemic shunt (TIPS) created with the Viabahn ePTFE covered stent/bare metal stent (BMS) combination and the Fluency ePTFE covered stent/BMS combination. METHODS: A total of 101 consecutive patients who received a TIPS from February 2016 to August 2018 in our center were retrospectively analyzed. Sixty-four subjects were enrolled in the Viabahn group and 37 were enrolled in the Fluency group. The geometry characteristics of the TIPS were calculated, and the associated occurrence of shunt dysfunction, survival, overt hepatic encephalopathy, and variceal rebleeding were evaluated. RESULTS: The technical success rate was 100%. After the insertion of the TIPS, the rate of shunt dysfunction during the first 3 months was significantly different between the Viabahn and Fluency groups (1.6% and 13.5%, respectively; p = 0.024). Multivariate analysis indicated that the angle of portal venous inflow (α) was the only independent risk factor for shunt dysfunction (hazard ratio = 1.060, 95% confidence interval = 1.009–1.112, p = 0.020). In addition, 3 months after the TIPS insertion, the α angle distinctly increased from 20.9° ± 14.3°–26.9° ± 20.1° (p = 0.005) in the Fluency group but did not change significantly in the Viabahn group (from 21.9° ± 15.1°–22.9° ± 17.6°, p = 0.798). CONCLUSIONS: Shunt dysfunction was related to the α angle owing to the slight effect on the α angle after the implantation of the TIPS. The Viabahn ePTFE covered stent/BMS combination was more stable in structure and promised higher short-term stent patency compared with the Fluency ePTFE covered stent/BMS combination. KeAi Publishing 2020-10-13 /pmc/articles/PMC8562232/ /pubmed/34805945 http://dx.doi.org/10.1016/j.jimed.2020.10.003 Text en © 2020 Shanghai Journal of Interventional Radiology Press. Publishing services by Elsevier B.V. on behalf of KeAi Communications Co. Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Article Liu, Jiacheng Meng, Jie Zhou, Chen Shi, Qin Yang, Chongtu Ma, Jinqiang Chen, Manman Xiong, Bin A new choice of stent for transjugular intrahepatic portosystemic shunt creation: Viabahn ePTFE covered stent/bare metal stent combination |
title | A new choice of stent for transjugular intrahepatic portosystemic shunt creation: Viabahn ePTFE covered stent/bare metal stent combination |
title_full | A new choice of stent for transjugular intrahepatic portosystemic shunt creation: Viabahn ePTFE covered stent/bare metal stent combination |
title_fullStr | A new choice of stent for transjugular intrahepatic portosystemic shunt creation: Viabahn ePTFE covered stent/bare metal stent combination |
title_full_unstemmed | A new choice of stent for transjugular intrahepatic portosystemic shunt creation: Viabahn ePTFE covered stent/bare metal stent combination |
title_short | A new choice of stent for transjugular intrahepatic portosystemic shunt creation: Viabahn ePTFE covered stent/bare metal stent combination |
title_sort | new choice of stent for transjugular intrahepatic portosystemic shunt creation: viabahn eptfe covered stent/bare metal stent combination |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8562232/ https://www.ncbi.nlm.nih.gov/pubmed/34805945 http://dx.doi.org/10.1016/j.jimed.2020.10.003 |
work_keys_str_mv | AT liujiacheng anewchoiceofstentfortransjugularintrahepaticportosystemicshuntcreationviabahneptfecoveredstentbaremetalstentcombination AT mengjie anewchoiceofstentfortransjugularintrahepaticportosystemicshuntcreationviabahneptfecoveredstentbaremetalstentcombination AT zhouchen anewchoiceofstentfortransjugularintrahepaticportosystemicshuntcreationviabahneptfecoveredstentbaremetalstentcombination AT shiqin anewchoiceofstentfortransjugularintrahepaticportosystemicshuntcreationviabahneptfecoveredstentbaremetalstentcombination AT yangchongtu anewchoiceofstentfortransjugularintrahepaticportosystemicshuntcreationviabahneptfecoveredstentbaremetalstentcombination AT majinqiang anewchoiceofstentfortransjugularintrahepaticportosystemicshuntcreationviabahneptfecoveredstentbaremetalstentcombination AT chenmanman anewchoiceofstentfortransjugularintrahepaticportosystemicshuntcreationviabahneptfecoveredstentbaremetalstentcombination AT xiongbin anewchoiceofstentfortransjugularintrahepaticportosystemicshuntcreationviabahneptfecoveredstentbaremetalstentcombination AT liujiacheng newchoiceofstentfortransjugularintrahepaticportosystemicshuntcreationviabahneptfecoveredstentbaremetalstentcombination AT mengjie newchoiceofstentfortransjugularintrahepaticportosystemicshuntcreationviabahneptfecoveredstentbaremetalstentcombination AT zhouchen newchoiceofstentfortransjugularintrahepaticportosystemicshuntcreationviabahneptfecoveredstentbaremetalstentcombination AT shiqin newchoiceofstentfortransjugularintrahepaticportosystemicshuntcreationviabahneptfecoveredstentbaremetalstentcombination AT yangchongtu newchoiceofstentfortransjugularintrahepaticportosystemicshuntcreationviabahneptfecoveredstentbaremetalstentcombination AT majinqiang newchoiceofstentfortransjugularintrahepaticportosystemicshuntcreationviabahneptfecoveredstentbaremetalstentcombination AT chenmanman newchoiceofstentfortransjugularintrahepaticportosystemicshuntcreationviabahneptfecoveredstentbaremetalstentcombination AT xiongbin newchoiceofstentfortransjugularintrahepaticportosystemicshuntcreationviabahneptfecoveredstentbaremetalstentcombination |