Cargando…
Persistent disseminated intravascular coagulation despite correction of endoleaks after thoracoabdominal endovascular aneurysm repair
Disseminated intravascular coagulation (DIC) is a rare complication of endovascular aortic repair, commonly associated with type I or type III endoleaks. DIC is also known as consumption coagulopathy because excessive thrombin formation and secondary fibrinolysis leads to consumption of coagulation...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8564492/ https://www.ncbi.nlm.nih.gov/pubmed/34754997 http://dx.doi.org/10.1016/j.jvscit.2021.08.012 |
_version_ | 1784593629969383424 |
---|---|
author | Kim, Ann H. King, Alexander H. Schmaier, Alvin H. Cho, Jae S. |
author_facet | Kim, Ann H. King, Alexander H. Schmaier, Alvin H. Cho, Jae S. |
author_sort | Kim, Ann H. |
collection | PubMed |
description | Disseminated intravascular coagulation (DIC) is a rare complication of endovascular aortic repair, commonly associated with type I or type III endoleaks. DIC is also known as consumption coagulopathy because excessive thrombin formation and secondary fibrinolysis leads to consumption of coagulation factors with hyperfibrinolysis and activation of platelets, which can lead to excessive bleeding. We present the case of an 80-year-old woman who had undergone thoracic endovascular aortic repair for a type B aortic dissection that was complicated by a series of recurrent endoleak-induced DICs requiring multiple thoracic endovascular aortic repair extensions to cover the entire thoracoabdominal aorta. The DIC persisted despite the resolution of the endoleaks. |
format | Online Article Text |
id | pubmed-8564492 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-85644922021-11-08 Persistent disseminated intravascular coagulation despite correction of endoleaks after thoracoabdominal endovascular aneurysm repair Kim, Ann H. King, Alexander H. Schmaier, Alvin H. Cho, Jae S. J Vasc Surg Cases Innov Tech Case report Disseminated intravascular coagulation (DIC) is a rare complication of endovascular aortic repair, commonly associated with type I or type III endoleaks. DIC is also known as consumption coagulopathy because excessive thrombin formation and secondary fibrinolysis leads to consumption of coagulation factors with hyperfibrinolysis and activation of platelets, which can lead to excessive bleeding. We present the case of an 80-year-old woman who had undergone thoracic endovascular aortic repair for a type B aortic dissection that was complicated by a series of recurrent endoleak-induced DICs requiring multiple thoracic endovascular aortic repair extensions to cover the entire thoracoabdominal aorta. The DIC persisted despite the resolution of the endoleaks. Elsevier 2021-09-29 /pmc/articles/PMC8564492/ /pubmed/34754997 http://dx.doi.org/10.1016/j.jvscit.2021.08.012 Text en © 2021 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case report Kim, Ann H. King, Alexander H. Schmaier, Alvin H. Cho, Jae S. Persistent disseminated intravascular coagulation despite correction of endoleaks after thoracoabdominal endovascular aneurysm repair |
title | Persistent disseminated intravascular coagulation despite correction of endoleaks after thoracoabdominal endovascular aneurysm repair |
title_full | Persistent disseminated intravascular coagulation despite correction of endoleaks after thoracoabdominal endovascular aneurysm repair |
title_fullStr | Persistent disseminated intravascular coagulation despite correction of endoleaks after thoracoabdominal endovascular aneurysm repair |
title_full_unstemmed | Persistent disseminated intravascular coagulation despite correction of endoleaks after thoracoabdominal endovascular aneurysm repair |
title_short | Persistent disseminated intravascular coagulation despite correction of endoleaks after thoracoabdominal endovascular aneurysm repair |
title_sort | persistent disseminated intravascular coagulation despite correction of endoleaks after thoracoabdominal endovascular aneurysm repair |
topic | Case report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8564492/ https://www.ncbi.nlm.nih.gov/pubmed/34754997 http://dx.doi.org/10.1016/j.jvscit.2021.08.012 |
work_keys_str_mv | AT kimannh persistentdisseminatedintravascularcoagulationdespitecorrectionofendoleaksafterthoracoabdominalendovascularaneurysmrepair AT kingalexanderh persistentdisseminatedintravascularcoagulationdespitecorrectionofendoleaksafterthoracoabdominalendovascularaneurysmrepair AT schmaieralvinh persistentdisseminatedintravascularcoagulationdespitecorrectionofendoleaksafterthoracoabdominalendovascularaneurysmrepair AT chojaes persistentdisseminatedintravascularcoagulationdespitecorrectionofendoleaksafterthoracoabdominalendovascularaneurysmrepair |