Effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients at a university hospital, Egypt

BACKGROUND: Manual hyperinflation and expiratory rib cage compression are methods of chest physiotherapy. They are commonly applied but their value and their early utilization managing mechanically ventilated remain questionable. The purpose of the study was to investigate the effects of manual hype...

Descripción completa

Detalles Bibliográficos
Autores principales: Khalil, Nahla Shaaban, Ismaeel, Manal Sayed, Askar, Ahmed Hassan, Sayed, Mohamed Soliman
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8564587/
http://dx.doi.org/10.1186/s43168-021-00096-5
_version_ 1784593648518692864
author Khalil, Nahla Shaaban
Ismaeel, Manal Sayed
Askar, Ahmed Hassan
Sayed, Mohamed Soliman
author_facet Khalil, Nahla Shaaban
Ismaeel, Manal Sayed
Askar, Ahmed Hassan
Sayed, Mohamed Soliman
author_sort Khalil, Nahla Shaaban
collection PubMed
description BACKGROUND: Manual hyperinflation and expiratory rib cage compression are methods of chest physiotherapy. They are commonly applied but their value and their early utilization managing mechanically ventilated remain questionable. The purpose of the study was to investigate the effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients. RESULTS: Seventy mechanically ventilated patients at a teaching hospital in Egypt were assigned to the clinical trial study. The age of more than half of the studied samples ranged between 60 and 69 years with a mean age of 53.64 ± 16.44 years. Initially, the ABG parameters were assessed. Then, the patients were exposed to manual hyperinflation for 5 min and 20 min external expiratory chest compression followed by endotracheal suctioning. Later, ABG parameters were assessed again and compared to the initial one. The findings revealed significant differences in ABG parameters before and after completion of MHI and ERCC and ETT suctioning in relation to PaO(2) (t = 3.892) and SaO(2) (t= 5.904). Also, it showed significant improvement in PaO(2) and SaO(2) after the completion of interventions, while no significant differences were found in other ABG parameters. This study was registered retrospectively with an ISRCTN number 39983 on 5/6/2021. CONCLUSION: Applying manual hyperinflation with rib cage compression and endotracheal suctioning improved mainly the arterial oxygenation parameters in mechanically ventilated patients despite no significant changes observed in other ABG parameters.
format Online
Article
Text
id pubmed-8564587
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-85645872021-11-03 Effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients at a university hospital, Egypt Khalil, Nahla Shaaban Ismaeel, Manal Sayed Askar, Ahmed Hassan Sayed, Mohamed Soliman Egypt J Bronchol Research BACKGROUND: Manual hyperinflation and expiratory rib cage compression are methods of chest physiotherapy. They are commonly applied but their value and their early utilization managing mechanically ventilated remain questionable. The purpose of the study was to investigate the effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients. RESULTS: Seventy mechanically ventilated patients at a teaching hospital in Egypt were assigned to the clinical trial study. The age of more than half of the studied samples ranged between 60 and 69 years with a mean age of 53.64 ± 16.44 years. Initially, the ABG parameters were assessed. Then, the patients were exposed to manual hyperinflation for 5 min and 20 min external expiratory chest compression followed by endotracheal suctioning. Later, ABG parameters were assessed again and compared to the initial one. The findings revealed significant differences in ABG parameters before and after completion of MHI and ERCC and ETT suctioning in relation to PaO(2) (t = 3.892) and SaO(2) (t= 5.904). Also, it showed significant improvement in PaO(2) and SaO(2) after the completion of interventions, while no significant differences were found in other ABG parameters. This study was registered retrospectively with an ISRCTN number 39983 on 5/6/2021. CONCLUSION: Applying manual hyperinflation with rib cage compression and endotracheal suctioning improved mainly the arterial oxygenation parameters in mechanically ventilated patients despite no significant changes observed in other ABG parameters. Springer Berlin Heidelberg 2021-11-03 2021 /pmc/articles/PMC8564587/ http://dx.doi.org/10.1186/s43168-021-00096-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research
Khalil, Nahla Shaaban
Ismaeel, Manal Sayed
Askar, Ahmed Hassan
Sayed, Mohamed Soliman
Effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients at a university hospital, Egypt
title Effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients at a university hospital, Egypt
title_full Effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients at a university hospital, Egypt
title_fullStr Effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients at a university hospital, Egypt
title_full_unstemmed Effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients at a university hospital, Egypt
title_short Effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients at a university hospital, Egypt
title_sort effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients at a university hospital, egypt
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8564587/
http://dx.doi.org/10.1186/s43168-021-00096-5
work_keys_str_mv AT khalilnahlashaaban effectsofmanualhyperinflationwithribcagecompressionandendotrachealsuctioningonarterialbloodgasparametersinmechanicallyventilatedpatientsatauniversityhospitalegypt
AT ismaeelmanalsayed effectsofmanualhyperinflationwithribcagecompressionandendotrachealsuctioningonarterialbloodgasparametersinmechanicallyventilatedpatientsatauniversityhospitalegypt
AT askarahmedhassan effectsofmanualhyperinflationwithribcagecompressionandendotrachealsuctioningonarterialbloodgasparametersinmechanicallyventilatedpatientsatauniversityhospitalegypt
AT sayedmohamedsoliman effectsofmanualhyperinflationwithribcagecompressionandendotrachealsuctioningonarterialbloodgasparametersinmechanicallyventilatedpatientsatauniversityhospitalegypt