Cargando…
Effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients at a university hospital, Egypt
BACKGROUND: Manual hyperinflation and expiratory rib cage compression are methods of chest physiotherapy. They are commonly applied but their value and their early utilization managing mechanically ventilated remain questionable. The purpose of the study was to investigate the effects of manual hype...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8564587/ http://dx.doi.org/10.1186/s43168-021-00096-5 |
_version_ | 1784593648518692864 |
---|---|
author | Khalil, Nahla Shaaban Ismaeel, Manal Sayed Askar, Ahmed Hassan Sayed, Mohamed Soliman |
author_facet | Khalil, Nahla Shaaban Ismaeel, Manal Sayed Askar, Ahmed Hassan Sayed, Mohamed Soliman |
author_sort | Khalil, Nahla Shaaban |
collection | PubMed |
description | BACKGROUND: Manual hyperinflation and expiratory rib cage compression are methods of chest physiotherapy. They are commonly applied but their value and their early utilization managing mechanically ventilated remain questionable. The purpose of the study was to investigate the effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients. RESULTS: Seventy mechanically ventilated patients at a teaching hospital in Egypt were assigned to the clinical trial study. The age of more than half of the studied samples ranged between 60 and 69 years with a mean age of 53.64 ± 16.44 years. Initially, the ABG parameters were assessed. Then, the patients were exposed to manual hyperinflation for 5 min and 20 min external expiratory chest compression followed by endotracheal suctioning. Later, ABG parameters were assessed again and compared to the initial one. The findings revealed significant differences in ABG parameters before and after completion of MHI and ERCC and ETT suctioning in relation to PaO(2) (t = 3.892) and SaO(2) (t= 5.904). Also, it showed significant improvement in PaO(2) and SaO(2) after the completion of interventions, while no significant differences were found in other ABG parameters. This study was registered retrospectively with an ISRCTN number 39983 on 5/6/2021. CONCLUSION: Applying manual hyperinflation with rib cage compression and endotracheal suctioning improved mainly the arterial oxygenation parameters in mechanically ventilated patients despite no significant changes observed in other ABG parameters. |
format | Online Article Text |
id | pubmed-8564587 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-85645872021-11-03 Effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients at a university hospital, Egypt Khalil, Nahla Shaaban Ismaeel, Manal Sayed Askar, Ahmed Hassan Sayed, Mohamed Soliman Egypt J Bronchol Research BACKGROUND: Manual hyperinflation and expiratory rib cage compression are methods of chest physiotherapy. They are commonly applied but their value and their early utilization managing mechanically ventilated remain questionable. The purpose of the study was to investigate the effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients. RESULTS: Seventy mechanically ventilated patients at a teaching hospital in Egypt were assigned to the clinical trial study. The age of more than half of the studied samples ranged between 60 and 69 years with a mean age of 53.64 ± 16.44 years. Initially, the ABG parameters were assessed. Then, the patients were exposed to manual hyperinflation for 5 min and 20 min external expiratory chest compression followed by endotracheal suctioning. Later, ABG parameters were assessed again and compared to the initial one. The findings revealed significant differences in ABG parameters before and after completion of MHI and ERCC and ETT suctioning in relation to PaO(2) (t = 3.892) and SaO(2) (t= 5.904). Also, it showed significant improvement in PaO(2) and SaO(2) after the completion of interventions, while no significant differences were found in other ABG parameters. This study was registered retrospectively with an ISRCTN number 39983 on 5/6/2021. CONCLUSION: Applying manual hyperinflation with rib cage compression and endotracheal suctioning improved mainly the arterial oxygenation parameters in mechanically ventilated patients despite no significant changes observed in other ABG parameters. Springer Berlin Heidelberg 2021-11-03 2021 /pmc/articles/PMC8564587/ http://dx.doi.org/10.1186/s43168-021-00096-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Khalil, Nahla Shaaban Ismaeel, Manal Sayed Askar, Ahmed Hassan Sayed, Mohamed Soliman Effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients at a university hospital, Egypt |
title | Effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients at a university hospital, Egypt |
title_full | Effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients at a university hospital, Egypt |
title_fullStr | Effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients at a university hospital, Egypt |
title_full_unstemmed | Effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients at a university hospital, Egypt |
title_short | Effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients at a university hospital, Egypt |
title_sort | effects of manual hyperinflation with rib cage compression and endotracheal suctioning on arterial blood gas parameters in mechanically ventilated patients at a university hospital, egypt |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8564587/ http://dx.doi.org/10.1186/s43168-021-00096-5 |
work_keys_str_mv | AT khalilnahlashaaban effectsofmanualhyperinflationwithribcagecompressionandendotrachealsuctioningonarterialbloodgasparametersinmechanicallyventilatedpatientsatauniversityhospitalegypt AT ismaeelmanalsayed effectsofmanualhyperinflationwithribcagecompressionandendotrachealsuctioningonarterialbloodgasparametersinmechanicallyventilatedpatientsatauniversityhospitalegypt AT askarahmedhassan effectsofmanualhyperinflationwithribcagecompressionandendotrachealsuctioningonarterialbloodgasparametersinmechanicallyventilatedpatientsatauniversityhospitalegypt AT sayedmohamedsoliman effectsofmanualhyperinflationwithribcagecompressionandendotrachealsuctioningonarterialbloodgasparametersinmechanicallyventilatedpatientsatauniversityhospitalegypt |