Cargando…

A comparative study of variable angle volar plate and bridging external fixator with K-wire augmentation in comminuted distal radius fractures

PURPOSE: Comminuted intraarticular distal radial fractures are difficult to treat conservatively and require operative treatment. This study compared the functional outcomes between variable angle volar plating and external fixator with K-wire augmentation in open reduction and internal fixation. ME...

Descripción completa

Detalles Bibliográficos
Autores principales: Mishra, Ratish Kumar, Sharma, Bhagwati Prasad, Kumar, Amit, Sherawat, Rohit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8564728/
https://www.ncbi.nlm.nih.gov/pubmed/33994084
http://dx.doi.org/10.1016/j.cjtee.2021.04.005
_version_ 1784593678045544448
author Mishra, Ratish Kumar
Sharma, Bhagwati Prasad
Kumar, Amit
Sherawat, Rohit
author_facet Mishra, Ratish Kumar
Sharma, Bhagwati Prasad
Kumar, Amit
Sherawat, Rohit
author_sort Mishra, Ratish Kumar
collection PubMed
description PURPOSE: Comminuted intraarticular distal radial fractures are difficult to treat conservatively and require operative treatment. This study compared the functional outcomes between variable angle volar plating and external fixator with K-wire augmentation in open reduction and internal fixation. METHODS: A total of 62 adult patients with comminuted intraarticular distal radius fracture were randomized into 2 groups: volar plate group and external fixator group. These patients aged between 18 and 60 years had unilateral fractures, and agreed to be included in the study. Patients with a history of fracture, bilateral fracture, associated other injuries, delayed injury for more than 2 weeks, open fracture, pre-existing arthrosis or disability, psychiatric illness and pathological fracture were excluded. Patients were followed up at 6 weeks, 3 months, 6 months and 1 year. The assessment of pain, functional activity, range of motion and grip strength was done at each stage of follow-up. The pain and functional activities were assessed by patient rated wrist evaluation (PRWE) score and disabilities of the arm, shoulder and hand (DASH) score. RESULTS: Patients in volar plate group had superior PRWE score and DASH score at each stage of follow-up. At 1 year follow-up, the mean PRWE score were 7.48 for volar plate group and 7.35 for external fixator group; while the mean DASH score was 4.65 for volar plate group and 5.61 for external fixator group. They had better flexion and extension range of movement. They also had better pronation and supination range of motion at initial follow-up, however the difference get attenuated by 1 year. Volar plate group had significantly better grip strength than external fixator group. Complication rates were higher in external fixation group. CONCLUSION: Fixation with variable angle volar plate results in early wrist mobilization, better range of movement, less pain and disability and early return of function.
format Online
Article
Text
id pubmed-8564728
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-85647282021-11-08 A comparative study of variable angle volar plate and bridging external fixator with K-wire augmentation in comminuted distal radius fractures Mishra, Ratish Kumar Sharma, Bhagwati Prasad Kumar, Amit Sherawat, Rohit Chin J Traumatol Original Article PURPOSE: Comminuted intraarticular distal radial fractures are difficult to treat conservatively and require operative treatment. This study compared the functional outcomes between variable angle volar plating and external fixator with K-wire augmentation in open reduction and internal fixation. METHODS: A total of 62 adult patients with comminuted intraarticular distal radius fracture were randomized into 2 groups: volar plate group and external fixator group. These patients aged between 18 and 60 years had unilateral fractures, and agreed to be included in the study. Patients with a history of fracture, bilateral fracture, associated other injuries, delayed injury for more than 2 weeks, open fracture, pre-existing arthrosis or disability, psychiatric illness and pathological fracture were excluded. Patients were followed up at 6 weeks, 3 months, 6 months and 1 year. The assessment of pain, functional activity, range of motion and grip strength was done at each stage of follow-up. The pain and functional activities were assessed by patient rated wrist evaluation (PRWE) score and disabilities of the arm, shoulder and hand (DASH) score. RESULTS: Patients in volar plate group had superior PRWE score and DASH score at each stage of follow-up. At 1 year follow-up, the mean PRWE score were 7.48 for volar plate group and 7.35 for external fixator group; while the mean DASH score was 4.65 for volar plate group and 5.61 for external fixator group. They had better flexion and extension range of movement. They also had better pronation and supination range of motion at initial follow-up, however the difference get attenuated by 1 year. Volar plate group had significantly better grip strength than external fixator group. Complication rates were higher in external fixation group. CONCLUSION: Fixation with variable angle volar plate results in early wrist mobilization, better range of movement, less pain and disability and early return of function. Elsevier 2021-09 2021-04-20 /pmc/articles/PMC8564728/ /pubmed/33994084 http://dx.doi.org/10.1016/j.cjtee.2021.04.005 Text en © 2021 Chinese Medical Association. Production and hosting by Elsevier B.V. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Mishra, Ratish Kumar
Sharma, Bhagwati Prasad
Kumar, Amit
Sherawat, Rohit
A comparative study of variable angle volar plate and bridging external fixator with K-wire augmentation in comminuted distal radius fractures
title A comparative study of variable angle volar plate and bridging external fixator with K-wire augmentation in comminuted distal radius fractures
title_full A comparative study of variable angle volar plate and bridging external fixator with K-wire augmentation in comminuted distal radius fractures
title_fullStr A comparative study of variable angle volar plate and bridging external fixator with K-wire augmentation in comminuted distal radius fractures
title_full_unstemmed A comparative study of variable angle volar plate and bridging external fixator with K-wire augmentation in comminuted distal radius fractures
title_short A comparative study of variable angle volar plate and bridging external fixator with K-wire augmentation in comminuted distal radius fractures
title_sort comparative study of variable angle volar plate and bridging external fixator with k-wire augmentation in comminuted distal radius fractures
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8564728/
https://www.ncbi.nlm.nih.gov/pubmed/33994084
http://dx.doi.org/10.1016/j.cjtee.2021.04.005
work_keys_str_mv AT mishraratishkumar acomparativestudyofvariableanglevolarplateandbridgingexternalfixatorwithkwireaugmentationincomminuteddistalradiusfractures
AT sharmabhagwatiprasad acomparativestudyofvariableanglevolarplateandbridgingexternalfixatorwithkwireaugmentationincomminuteddistalradiusfractures
AT kumaramit acomparativestudyofvariableanglevolarplateandbridgingexternalfixatorwithkwireaugmentationincomminuteddistalradiusfractures
AT sherawatrohit acomparativestudyofvariableanglevolarplateandbridgingexternalfixatorwithkwireaugmentationincomminuteddistalradiusfractures
AT mishraratishkumar comparativestudyofvariableanglevolarplateandbridgingexternalfixatorwithkwireaugmentationincomminuteddistalradiusfractures
AT sharmabhagwatiprasad comparativestudyofvariableanglevolarplateandbridgingexternalfixatorwithkwireaugmentationincomminuteddistalradiusfractures
AT kumaramit comparativestudyofvariableanglevolarplateandbridgingexternalfixatorwithkwireaugmentationincomminuteddistalradiusfractures
AT sherawatrohit comparativestudyofvariableanglevolarplateandbridgingexternalfixatorwithkwireaugmentationincomminuteddistalradiusfractures