Cargando…

Quantitative and Semi-quantitative Methods for Assessing the Degree of Methylene Blue Staining in Sentinel Lymph Nodes in Dogs

Background: To develop a digital algorithm for quantitative assessment of surface methylene blue staining in whole lymph nodes and validate a semi-quantitative visual scoring method for patient-side use. Methods: Lymph nodes from canine patients with spontaneous tumors undergoing sentinel lymph node...

Descripción completa

Detalles Bibliográficos
Autores principales: Ram, Ann S., Matuszewska, Kathy, Petrik, Jim, Singh, Ameet, Oblak, Michelle L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8567073/
https://www.ncbi.nlm.nih.gov/pubmed/34746290
http://dx.doi.org/10.3389/fvets.2021.758295
_version_ 1784594156695322624
author Ram, Ann S.
Matuszewska, Kathy
Petrik, Jim
Singh, Ameet
Oblak, Michelle L.
author_facet Ram, Ann S.
Matuszewska, Kathy
Petrik, Jim
Singh, Ameet
Oblak, Michelle L.
author_sort Ram, Ann S.
collection PubMed
description Background: To develop a digital algorithm for quantitative assessment of surface methylene blue staining in whole lymph nodes and validate a semi-quantitative visual scoring method for patient-side use. Methods: Lymph nodes from canine patients with spontaneous tumors undergoing sentinel lymph node mapping were prospectively assessed ex vivo and photographed. Using an open-source computer-based imaging software, an algorithm was developed for quantification of staining based on a signal-to-background ratio. Next, two blinded observers evaluated images and assigned a semi-quantitative visual score based on surface staining (0—no blue stain, 1−1–50% stained, and 2−51–100% stained) and those results were compared to the established quantitative standard. Results: Forty-three lymph nodes were included. Image analysis successfully quantified blue staining and differentiated from normal lymph node tissue in all cases. Agreement between observers using the Kappa coefficient demonstrated strong agreement (k = 0.8581, p < 0.0001) between semi-quantitative visual scoring and image analysis. There was substantial interobserver and intraobserver agreement for the scoring system (k = 0.7340, p < 0.0001 and k = 0.8983, p < 0.0001, respectively). Conclusion: A digital algorithm using an open-source software was simple and straightforward to use for quantification of blue staining. The use of a semi-quantitative visual scoring system shows promise for a simple, objective, repeatable assessment of methylene blue staining at the time of surgery. This study demonstrates reliable and repeatable methods for blue staining quantification thereby providing a novel and objective reporting mechanism in scientific research involving sentinel lymph node mapping.
format Online
Article
Text
id pubmed-8567073
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-85670732021-11-05 Quantitative and Semi-quantitative Methods for Assessing the Degree of Methylene Blue Staining in Sentinel Lymph Nodes in Dogs Ram, Ann S. Matuszewska, Kathy Petrik, Jim Singh, Ameet Oblak, Michelle L. Front Vet Sci Veterinary Science Background: To develop a digital algorithm for quantitative assessment of surface methylene blue staining in whole lymph nodes and validate a semi-quantitative visual scoring method for patient-side use. Methods: Lymph nodes from canine patients with spontaneous tumors undergoing sentinel lymph node mapping were prospectively assessed ex vivo and photographed. Using an open-source computer-based imaging software, an algorithm was developed for quantification of staining based on a signal-to-background ratio. Next, two blinded observers evaluated images and assigned a semi-quantitative visual score based on surface staining (0—no blue stain, 1−1–50% stained, and 2−51–100% stained) and those results were compared to the established quantitative standard. Results: Forty-three lymph nodes were included. Image analysis successfully quantified blue staining and differentiated from normal lymph node tissue in all cases. Agreement between observers using the Kappa coefficient demonstrated strong agreement (k = 0.8581, p < 0.0001) between semi-quantitative visual scoring and image analysis. There was substantial interobserver and intraobserver agreement for the scoring system (k = 0.7340, p < 0.0001 and k = 0.8983, p < 0.0001, respectively). Conclusion: A digital algorithm using an open-source software was simple and straightforward to use for quantification of blue staining. The use of a semi-quantitative visual scoring system shows promise for a simple, objective, repeatable assessment of methylene blue staining at the time of surgery. This study demonstrates reliable and repeatable methods for blue staining quantification thereby providing a novel and objective reporting mechanism in scientific research involving sentinel lymph node mapping. Frontiers Media S.A. 2021-10-21 /pmc/articles/PMC8567073/ /pubmed/34746290 http://dx.doi.org/10.3389/fvets.2021.758295 Text en Copyright © 2021 Ram, Matuszewska, Petrik, Singh and Oblak. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Veterinary Science
Ram, Ann S.
Matuszewska, Kathy
Petrik, Jim
Singh, Ameet
Oblak, Michelle L.
Quantitative and Semi-quantitative Methods for Assessing the Degree of Methylene Blue Staining in Sentinel Lymph Nodes in Dogs
title Quantitative and Semi-quantitative Methods for Assessing the Degree of Methylene Blue Staining in Sentinel Lymph Nodes in Dogs
title_full Quantitative and Semi-quantitative Methods for Assessing the Degree of Methylene Blue Staining in Sentinel Lymph Nodes in Dogs
title_fullStr Quantitative and Semi-quantitative Methods for Assessing the Degree of Methylene Blue Staining in Sentinel Lymph Nodes in Dogs
title_full_unstemmed Quantitative and Semi-quantitative Methods for Assessing the Degree of Methylene Blue Staining in Sentinel Lymph Nodes in Dogs
title_short Quantitative and Semi-quantitative Methods for Assessing the Degree of Methylene Blue Staining in Sentinel Lymph Nodes in Dogs
title_sort quantitative and semi-quantitative methods for assessing the degree of methylene blue staining in sentinel lymph nodes in dogs
topic Veterinary Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8567073/
https://www.ncbi.nlm.nih.gov/pubmed/34746290
http://dx.doi.org/10.3389/fvets.2021.758295
work_keys_str_mv AT ramanns quantitativeandsemiquantitativemethodsforassessingthedegreeofmethylenebluestaininginsentinellymphnodesindogs
AT matuszewskakathy quantitativeandsemiquantitativemethodsforassessingthedegreeofmethylenebluestaininginsentinellymphnodesindogs
AT petrikjim quantitativeandsemiquantitativemethodsforassessingthedegreeofmethylenebluestaininginsentinellymphnodesindogs
AT singhameet quantitativeandsemiquantitativemethodsforassessingthedegreeofmethylenebluestaininginsentinellymphnodesindogs
AT oblakmichellel quantitativeandsemiquantitativemethodsforassessingthedegreeofmethylenebluestaininginsentinellymphnodesindogs