Cargando…
Potential value of the calibrated automated thrombogram in patients after a cerebral venous sinus thrombosis; an exploratory study
BACKGROUND: Cerebral venous sinus thrombosis (CVST) is a relatively rare, but potentially lethal condition. In approximately 15% of the patients, the cause of CVST remains unclear. Conventional clotting tests such as prothrombin time and activated partial thromboplastin time are not sensitive enough...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8567338/ https://www.ncbi.nlm.nih.gov/pubmed/34736478 http://dx.doi.org/10.1186/s12959-021-00335-1 |
_version_ | 1784594209010876416 |
---|---|
author | van der Bruggen, Myrthe M. Kremers, Bram van Oerle, Rene van Oostenbrugge, Robert J. ten Cate, Hugo |
author_facet | van der Bruggen, Myrthe M. Kremers, Bram van Oerle, Rene van Oostenbrugge, Robert J. ten Cate, Hugo |
author_sort | van der Bruggen, Myrthe M. |
collection | PubMed |
description | BACKGROUND: Cerebral venous sinus thrombosis (CVST) is a relatively rare, but potentially lethal condition. In approximately 15% of the patients, the cause of CVST remains unclear. Conventional clotting tests such as prothrombin time and activated partial thromboplastin time are not sensitive enough to detect prothrombotic conditions nor mild haemostatic abnormalities. The calibrated automated thrombogram (CAT) is a physiological function test that might be able to detect minor aberrations in haemostasis. Therefore, we aimed to detect the presence of a prothrombotic state in patients who endured idiopathic CVST with the CAT assay. METHODS: Five adult patients with an idiopathic, radiologically proven CVST that had been admitted during the past 3 years were included in this study. The control group consisted of five age/gender matched healthy volunteers. Exclusion criteria were known haematological disorders, malignancy (current/past) or hormonal and anticoagulant therapy recipients. We obtained venous blood samples from all participants following cessation of anticoagulation. Using the CAT assay, we determined lag time, normalized endogenous thrombin potential (ETP), ETP reduction and normalized peak height. In addition, prothrombin concentrations were determined. RESULTS: We found no significant differences in lag time (4.7 min [4.5–4.9] vs 5.3 min [3.7–5.7], p = 0.691), normalized ETP (142% [124–148] vs 124% [88–138], p = 0.222), ETP reduction (29% [26–35] vs 28% [24–58], p > 0.999), and normalized peak height (155% [153–175] vs 137 [94–154], p = 0.056) between patients and their age/gender matched controls. In addition, prothrombin concentrations did not significantly differ between patients and controls (120% [105–132] vs 127% [87–139], p > 0.999). CONCLUSION: Reasons for absent overt hypercoagulability within this study population may be the small patient sample, long time since the event (e.g. 3 years) and avoidance of acquired risk factors like oral contraception. Given the fact that CVST is a serious condition with a more than negligible risk of venous thrombosis event recurrence, exclusion of clinically relevant hypercoagulability remains a challenging topic to further study at the acute and later time points, particularly in patients with idiopathic CVST. |
format | Online Article Text |
id | pubmed-8567338 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-85673382021-11-04 Potential value of the calibrated automated thrombogram in patients after a cerebral venous sinus thrombosis; an exploratory study van der Bruggen, Myrthe M. Kremers, Bram van Oerle, Rene van Oostenbrugge, Robert J. ten Cate, Hugo Thromb J Research BACKGROUND: Cerebral venous sinus thrombosis (CVST) is a relatively rare, but potentially lethal condition. In approximately 15% of the patients, the cause of CVST remains unclear. Conventional clotting tests such as prothrombin time and activated partial thromboplastin time are not sensitive enough to detect prothrombotic conditions nor mild haemostatic abnormalities. The calibrated automated thrombogram (CAT) is a physiological function test that might be able to detect minor aberrations in haemostasis. Therefore, we aimed to detect the presence of a prothrombotic state in patients who endured idiopathic CVST with the CAT assay. METHODS: Five adult patients with an idiopathic, radiologically proven CVST that had been admitted during the past 3 years were included in this study. The control group consisted of five age/gender matched healthy volunteers. Exclusion criteria were known haematological disorders, malignancy (current/past) or hormonal and anticoagulant therapy recipients. We obtained venous blood samples from all participants following cessation of anticoagulation. Using the CAT assay, we determined lag time, normalized endogenous thrombin potential (ETP), ETP reduction and normalized peak height. In addition, prothrombin concentrations were determined. RESULTS: We found no significant differences in lag time (4.7 min [4.5–4.9] vs 5.3 min [3.7–5.7], p = 0.691), normalized ETP (142% [124–148] vs 124% [88–138], p = 0.222), ETP reduction (29% [26–35] vs 28% [24–58], p > 0.999), and normalized peak height (155% [153–175] vs 137 [94–154], p = 0.056) between patients and their age/gender matched controls. In addition, prothrombin concentrations did not significantly differ between patients and controls (120% [105–132] vs 127% [87–139], p > 0.999). CONCLUSION: Reasons for absent overt hypercoagulability within this study population may be the small patient sample, long time since the event (e.g. 3 years) and avoidance of acquired risk factors like oral contraception. Given the fact that CVST is a serious condition with a more than negligible risk of venous thrombosis event recurrence, exclusion of clinically relevant hypercoagulability remains a challenging topic to further study at the acute and later time points, particularly in patients with idiopathic CVST. BioMed Central 2021-11-04 /pmc/articles/PMC8567338/ /pubmed/34736478 http://dx.doi.org/10.1186/s12959-021-00335-1 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research van der Bruggen, Myrthe M. Kremers, Bram van Oerle, Rene van Oostenbrugge, Robert J. ten Cate, Hugo Potential value of the calibrated automated thrombogram in patients after a cerebral venous sinus thrombosis; an exploratory study |
title | Potential value of the calibrated automated thrombogram in patients after a cerebral venous sinus thrombosis; an exploratory study |
title_full | Potential value of the calibrated automated thrombogram in patients after a cerebral venous sinus thrombosis; an exploratory study |
title_fullStr | Potential value of the calibrated automated thrombogram in patients after a cerebral venous sinus thrombosis; an exploratory study |
title_full_unstemmed | Potential value of the calibrated automated thrombogram in patients after a cerebral venous sinus thrombosis; an exploratory study |
title_short | Potential value of the calibrated automated thrombogram in patients after a cerebral venous sinus thrombosis; an exploratory study |
title_sort | potential value of the calibrated automated thrombogram in patients after a cerebral venous sinus thrombosis; an exploratory study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8567338/ https://www.ncbi.nlm.nih.gov/pubmed/34736478 http://dx.doi.org/10.1186/s12959-021-00335-1 |
work_keys_str_mv | AT vanderbruggenmyrthem potentialvalueofthecalibratedautomatedthrombograminpatientsafteracerebralvenoussinusthrombosisanexploratorystudy AT kremersbram potentialvalueofthecalibratedautomatedthrombograminpatientsafteracerebralvenoussinusthrombosisanexploratorystudy AT vanoerlerene potentialvalueofthecalibratedautomatedthrombograminpatientsafteracerebralvenoussinusthrombosisanexploratorystudy AT vanoostenbruggerobertj potentialvalueofthecalibratedautomatedthrombograminpatientsafteracerebralvenoussinusthrombosisanexploratorystudy AT tencatehugo potentialvalueofthecalibratedautomatedthrombograminpatientsafteracerebralvenoussinusthrombosisanexploratorystudy |