Cargando…

Accuracy and reliability of focused echocardiography in patients with Chagas disease from endemic areas: SaMi-Trop cohort study

BACKGROUND: Chagas disease remains a major cause of cardiovascular death in endemic areas. Focused echocardiography (FoCUS) is a point-of-care means of assessing cardiac function which can be useful for the diagnosis of cardiac involvement. OBJECTIVE: This study aims evaluating the characteristics o...

Descripción completa

Detalles Bibliográficos
Autores principales: Martins Barros, Isabella Morais, Barros, Marcio Vinicius L., Almeida Martins, Larissa Natany, Ribeiro, Antonio Luiz P., de Camargo, Raul Silva Simões, Oliveira, Claudia Di Lorenzo, Ferreira, Ariela Mota, de Oliveira, Lea Campos, Bierrenbach, Ana Luiza, Haikal, Desireé Sant´Ana, Sabino, Ester Cerdeira, Cardoso, Clareci S., Nunes, Maria Carmo Pereira
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8568132/
https://www.ncbi.nlm.nih.gov/pubmed/34735475
http://dx.doi.org/10.1371/journal.pone.0258767
_version_ 1784594369752334336
author Martins Barros, Isabella Morais
Barros, Marcio Vinicius L.
Almeida Martins, Larissa Natany
Ribeiro, Antonio Luiz P.
de Camargo, Raul Silva Simões
Oliveira, Claudia Di Lorenzo
Ferreira, Ariela Mota
de Oliveira, Lea Campos
Bierrenbach, Ana Luiza
Haikal, Desireé Sant´Ana
Sabino, Ester Cerdeira
Cardoso, Clareci S.
Nunes, Maria Carmo Pereira
author_facet Martins Barros, Isabella Morais
Barros, Marcio Vinicius L.
Almeida Martins, Larissa Natany
Ribeiro, Antonio Luiz P.
de Camargo, Raul Silva Simões
Oliveira, Claudia Di Lorenzo
Ferreira, Ariela Mota
de Oliveira, Lea Campos
Bierrenbach, Ana Luiza
Haikal, Desireé Sant´Ana
Sabino, Ester Cerdeira
Cardoso, Clareci S.
Nunes, Maria Carmo Pereira
author_sort Martins Barros, Isabella Morais
collection PubMed
description BACKGROUND: Chagas disease remains a major cause of cardiovascular death in endemic areas. Focused echocardiography (FoCUS) is a point-of-care means of assessing cardiac function which can be useful for the diagnosis of cardiac involvement. OBJECTIVE: This study aims evaluating the characteristics of validity and reliability of FoCUS applied on Chagas disease patients. METHODS: Patients with Chagas disease coming from an endemic area were selected from a large cohort (SaMi-Trop). A simplified echocardiogram with only three images was extracted from the conventional echocardiogram performed in this cohort. The images were evaluated by an observer who was blinded to the clinical and echocardiographic data, to determine the accuracy and reliability of FoCUS for cardiac assessment. The analysis constituted of 5 prespecified variables, dichotomized in absence or presence: left ventricular (LV) size and systolic function, right ventricular (RV) size and systolic function, and LV aneurysm. RESULTS: We included 725 patients with a mean age of 63.4 ± 12.3 years, 483 (67%) female. Abnormal electrocardiogram was observed in 81.5% of the patients. Left and right ventricular dysfunctions were found in 103 (14%) and 49 (7%) of the patients, respectively. Sensitivity, specificity, positive predictive value and negative predictive value were 84%, 94%, 70% and 97% for LV enlargement and 81%, 93%, 68% and 97% for LV systolic dysfunction, respectively, and 46%, 99%, 60% and 98% for RV dilatation, and 37%, 100%, 100% and 96% for RV dysfunction, respectively. Inter and intraobserver agreement were 61% and 87% for LV enlargement and 63% and 92% for LV dysfunction, respectively, and 50% and 49% for RV size and 46% and 79% for RV dysfunction, respectively. LV apical aneurysm was found in 45 patients (6.2%) with the lowest sensitivity of FoCUS study (11%; 95% CI 2–28%). CONCLUSIONS: FoCUS showed satisfactory values of validity and reliability for assessment of cardiac chambers in patients with Chagas disease, except for apical aneurysm. This tool can identify heart disease with potential impact on patient management in the limited-resource setting.
format Online
Article
Text
id pubmed-8568132
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-85681322021-11-05 Accuracy and reliability of focused echocardiography in patients with Chagas disease from endemic areas: SaMi-Trop cohort study Martins Barros, Isabella Morais Barros, Marcio Vinicius L. Almeida Martins, Larissa Natany Ribeiro, Antonio Luiz P. de Camargo, Raul Silva Simões Oliveira, Claudia Di Lorenzo Ferreira, Ariela Mota de Oliveira, Lea Campos Bierrenbach, Ana Luiza Haikal, Desireé Sant´Ana Sabino, Ester Cerdeira Cardoso, Clareci S. Nunes, Maria Carmo Pereira PLoS One Research Article BACKGROUND: Chagas disease remains a major cause of cardiovascular death in endemic areas. Focused echocardiography (FoCUS) is a point-of-care means of assessing cardiac function which can be useful for the diagnosis of cardiac involvement. OBJECTIVE: This study aims evaluating the characteristics of validity and reliability of FoCUS applied on Chagas disease patients. METHODS: Patients with Chagas disease coming from an endemic area were selected from a large cohort (SaMi-Trop). A simplified echocardiogram with only three images was extracted from the conventional echocardiogram performed in this cohort. The images were evaluated by an observer who was blinded to the clinical and echocardiographic data, to determine the accuracy and reliability of FoCUS for cardiac assessment. The analysis constituted of 5 prespecified variables, dichotomized in absence or presence: left ventricular (LV) size and systolic function, right ventricular (RV) size and systolic function, and LV aneurysm. RESULTS: We included 725 patients with a mean age of 63.4 ± 12.3 years, 483 (67%) female. Abnormal electrocardiogram was observed in 81.5% of the patients. Left and right ventricular dysfunctions were found in 103 (14%) and 49 (7%) of the patients, respectively. Sensitivity, specificity, positive predictive value and negative predictive value were 84%, 94%, 70% and 97% for LV enlargement and 81%, 93%, 68% and 97% for LV systolic dysfunction, respectively, and 46%, 99%, 60% and 98% for RV dilatation, and 37%, 100%, 100% and 96% for RV dysfunction, respectively. Inter and intraobserver agreement were 61% and 87% for LV enlargement and 63% and 92% for LV dysfunction, respectively, and 50% and 49% for RV size and 46% and 79% for RV dysfunction, respectively. LV apical aneurysm was found in 45 patients (6.2%) with the lowest sensitivity of FoCUS study (11%; 95% CI 2–28%). CONCLUSIONS: FoCUS showed satisfactory values of validity and reliability for assessment of cardiac chambers in patients with Chagas disease, except for apical aneurysm. This tool can identify heart disease with potential impact on patient management in the limited-resource setting. Public Library of Science 2021-11-04 /pmc/articles/PMC8568132/ /pubmed/34735475 http://dx.doi.org/10.1371/journal.pone.0258767 Text en © 2021 Martins Barros et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Martins Barros, Isabella Morais
Barros, Marcio Vinicius L.
Almeida Martins, Larissa Natany
Ribeiro, Antonio Luiz P.
de Camargo, Raul Silva Simões
Oliveira, Claudia Di Lorenzo
Ferreira, Ariela Mota
de Oliveira, Lea Campos
Bierrenbach, Ana Luiza
Haikal, Desireé Sant´Ana
Sabino, Ester Cerdeira
Cardoso, Clareci S.
Nunes, Maria Carmo Pereira
Accuracy and reliability of focused echocardiography in patients with Chagas disease from endemic areas: SaMi-Trop cohort study
title Accuracy and reliability of focused echocardiography in patients with Chagas disease from endemic areas: SaMi-Trop cohort study
title_full Accuracy and reliability of focused echocardiography in patients with Chagas disease from endemic areas: SaMi-Trop cohort study
title_fullStr Accuracy and reliability of focused echocardiography in patients with Chagas disease from endemic areas: SaMi-Trop cohort study
title_full_unstemmed Accuracy and reliability of focused echocardiography in patients with Chagas disease from endemic areas: SaMi-Trop cohort study
title_short Accuracy and reliability of focused echocardiography in patients with Chagas disease from endemic areas: SaMi-Trop cohort study
title_sort accuracy and reliability of focused echocardiography in patients with chagas disease from endemic areas: sami-trop cohort study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8568132/
https://www.ncbi.nlm.nih.gov/pubmed/34735475
http://dx.doi.org/10.1371/journal.pone.0258767
work_keys_str_mv AT martinsbarrosisabellamorais accuracyandreliabilityoffocusedechocardiographyinpatientswithchagasdiseasefromendemicareassamitropcohortstudy
AT barrosmarcioviniciusl accuracyandreliabilityoffocusedechocardiographyinpatientswithchagasdiseasefromendemicareassamitropcohortstudy
AT almeidamartinslarissanatany accuracyandreliabilityoffocusedechocardiographyinpatientswithchagasdiseasefromendemicareassamitropcohortstudy
AT ribeiroantonioluizp accuracyandreliabilityoffocusedechocardiographyinpatientswithchagasdiseasefromendemicareassamitropcohortstudy
AT decamargoraulsilvasimoes accuracyandreliabilityoffocusedechocardiographyinpatientswithchagasdiseasefromendemicareassamitropcohortstudy
AT oliveiraclaudiadilorenzo accuracyandreliabilityoffocusedechocardiographyinpatientswithchagasdiseasefromendemicareassamitropcohortstudy
AT ferreiraarielamota accuracyandreliabilityoffocusedechocardiographyinpatientswithchagasdiseasefromendemicareassamitropcohortstudy
AT deoliveiraleacampos accuracyandreliabilityoffocusedechocardiographyinpatientswithchagasdiseasefromendemicareassamitropcohortstudy
AT bierrenbachanaluiza accuracyandreliabilityoffocusedechocardiographyinpatientswithchagasdiseasefromendemicareassamitropcohortstudy
AT haikaldesireesantana accuracyandreliabilityoffocusedechocardiographyinpatientswithchagasdiseasefromendemicareassamitropcohortstudy
AT sabinoestercerdeira accuracyandreliabilityoffocusedechocardiographyinpatientswithchagasdiseasefromendemicareassamitropcohortstudy
AT cardosoclarecis accuracyandreliabilityoffocusedechocardiographyinpatientswithchagasdiseasefromendemicareassamitropcohortstudy
AT nunesmariacarmopereira accuracyandreliabilityoffocusedechocardiographyinpatientswithchagasdiseasefromendemicareassamitropcohortstudy