Cargando…
Is there a correlation between functional results and radiographic findings in patients with distal radius fracture A0 type A3 treated with volar locking plate or external fixator?
The aim of this study was to test the hypothesis that precise restoration of distal radius fractures is correlated to better patient-reported outcome. METHODS: The correlation between radiographic results and functional outcome was explored in 156 patients with extra-articular distal radius fracture...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8568390/ https://www.ncbi.nlm.nih.gov/pubmed/34746674 http://dx.doi.org/10.1097/OI9.0000000000000142 |
_version_ | 1784594427218493440 |
---|---|
author | Ludvigsen, Trine Matre, Kjell Vetti, Nils Kristoffersen, Per Martin Toppe, Monika Kolskår Gudmundsdottir, Rakel Krukhaug, Yngvar Dybvik, Eva Fevang, Jonas Meling |
author_facet | Ludvigsen, Trine Matre, Kjell Vetti, Nils Kristoffersen, Per Martin Toppe, Monika Kolskår Gudmundsdottir, Rakel Krukhaug, Yngvar Dybvik, Eva Fevang, Jonas Meling |
author_sort | Ludvigsen, Trine |
collection | PubMed |
description | The aim of this study was to test the hypothesis that precise restoration of distal radius fractures is correlated to better patient-reported outcome. METHODS: The correlation between radiographic results and functional outcome was explored in 156 patients with extra-articular distal radius fractures included in a multicenter, randomized controlled trial comparing 2 surgical interventions, Volar Locking Plate or External Fixator. The primary functional outcome was the Patient Rated Wrist and Hand Evaluation score (PRWHE). Radiographically we assessed volar tilt, radial inclination, radial height, ulnar variance, and the presence of ulnar styloid fracture. The Pearson correlation analysis was used to estimate correlations between parameters. RESULTS: At 1-year follow-up the mean difference in radiographic findings compared with the uninjured side (min, max) was: reduced volar tilt 5.3° (−15°, 25°), reduced radial inclination 2.3° (−6°, 12°), radial height 1.3 mm (−4 mm, 7 mm), and ulnar variance −0.5 mm (−6 mm, 3 mm). Overall, we found no correlation between radiographic parameters and the PRWHE at 1-year follow-up within the whole group, regardless of which treatment was chosen. At the time of injury 53% (N = 80) had sustained an additional ulnar styloid fracture. After 1 year this fracture was still radiographically present in 31% (N = 43) of the patients. No correlation between PRWHE score and the presence of an ulnar styloid fracture at 1-year follow-up was found. CONCLUSIONS: We found no correlation between functional outcome (PRWHE) and radiographic findings after 1 year in patients operated on with a Volar Locking Plate or External Fixator. Patient-specific factors were more important than radiographic measurements in this study group. Level of evidence: Therapeutic Level 2 Trial registration: Norway: National Committee for Medical and Health Research Ethics 213/555 ClinicalTrials.gov ID: NCT01904084 Randomization of first patient: 02.09.2013 |
format | Online Article Text |
id | pubmed-8568390 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-85683902021-11-05 Is there a correlation between functional results and radiographic findings in patients with distal radius fracture A0 type A3 treated with volar locking plate or external fixator? Ludvigsen, Trine Matre, Kjell Vetti, Nils Kristoffersen, Per Martin Toppe, Monika Kolskår Gudmundsdottir, Rakel Krukhaug, Yngvar Dybvik, Eva Fevang, Jonas Meling OTA Int Clinical/Basic Science Research Article The aim of this study was to test the hypothesis that precise restoration of distal radius fractures is correlated to better patient-reported outcome. METHODS: The correlation between radiographic results and functional outcome was explored in 156 patients with extra-articular distal radius fractures included in a multicenter, randomized controlled trial comparing 2 surgical interventions, Volar Locking Plate or External Fixator. The primary functional outcome was the Patient Rated Wrist and Hand Evaluation score (PRWHE). Radiographically we assessed volar tilt, radial inclination, radial height, ulnar variance, and the presence of ulnar styloid fracture. The Pearson correlation analysis was used to estimate correlations between parameters. RESULTS: At 1-year follow-up the mean difference in radiographic findings compared with the uninjured side (min, max) was: reduced volar tilt 5.3° (−15°, 25°), reduced radial inclination 2.3° (−6°, 12°), radial height 1.3 mm (−4 mm, 7 mm), and ulnar variance −0.5 mm (−6 mm, 3 mm). Overall, we found no correlation between radiographic parameters and the PRWHE at 1-year follow-up within the whole group, regardless of which treatment was chosen. At the time of injury 53% (N = 80) had sustained an additional ulnar styloid fracture. After 1 year this fracture was still radiographically present in 31% (N = 43) of the patients. No correlation between PRWHE score and the presence of an ulnar styloid fracture at 1-year follow-up was found. CONCLUSIONS: We found no correlation between functional outcome (PRWHE) and radiographic findings after 1 year in patients operated on with a Volar Locking Plate or External Fixator. Patient-specific factors were more important than radiographic measurements in this study group. Level of evidence: Therapeutic Level 2 Trial registration: Norway: National Committee for Medical and Health Research Ethics 213/555 ClinicalTrials.gov ID: NCT01904084 Randomization of first patient: 02.09.2013 Lippincott Williams & Wilkins 2021-08-09 /pmc/articles/PMC8568390/ /pubmed/34746674 http://dx.doi.org/10.1097/OI9.0000000000000142 Text en Copyright © 2021 The Authors. Published by Wolters Kluwer Health, Inc. on behalf of the Orthopaedic Trauma Association. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Clinical/Basic Science Research Article Ludvigsen, Trine Matre, Kjell Vetti, Nils Kristoffersen, Per Martin Toppe, Monika Kolskår Gudmundsdottir, Rakel Krukhaug, Yngvar Dybvik, Eva Fevang, Jonas Meling Is there a correlation between functional results and radiographic findings in patients with distal radius fracture A0 type A3 treated with volar locking plate or external fixator? |
title | Is there a correlation between functional results and radiographic findings in patients with distal radius fracture A0 type A3 treated with volar locking plate or external fixator? |
title_full | Is there a correlation between functional results and radiographic findings in patients with distal radius fracture A0 type A3 treated with volar locking plate or external fixator? |
title_fullStr | Is there a correlation between functional results and radiographic findings in patients with distal radius fracture A0 type A3 treated with volar locking plate or external fixator? |
title_full_unstemmed | Is there a correlation between functional results and radiographic findings in patients with distal radius fracture A0 type A3 treated with volar locking plate or external fixator? |
title_short | Is there a correlation between functional results and radiographic findings in patients with distal radius fracture A0 type A3 treated with volar locking plate or external fixator? |
title_sort | is there a correlation between functional results and radiographic findings in patients with distal radius fracture a0 type a3 treated with volar locking plate or external fixator? |
topic | Clinical/Basic Science Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8568390/ https://www.ncbi.nlm.nih.gov/pubmed/34746674 http://dx.doi.org/10.1097/OI9.0000000000000142 |
work_keys_str_mv | AT ludvigsentrine isthereacorrelationbetweenfunctionalresultsandradiographicfindingsinpatientswithdistalradiusfracturea0typea3treatedwithvolarlockingplateorexternalfixator AT matrekjell isthereacorrelationbetweenfunctionalresultsandradiographicfindingsinpatientswithdistalradiusfracturea0typea3treatedwithvolarlockingplateorexternalfixator AT vettinils isthereacorrelationbetweenfunctionalresultsandradiographicfindingsinpatientswithdistalradiusfracturea0typea3treatedwithvolarlockingplateorexternalfixator AT kristoffersenpermartin isthereacorrelationbetweenfunctionalresultsandradiographicfindingsinpatientswithdistalradiusfracturea0typea3treatedwithvolarlockingplateorexternalfixator AT toppemonikakolskar isthereacorrelationbetweenfunctionalresultsandradiographicfindingsinpatientswithdistalradiusfracturea0typea3treatedwithvolarlockingplateorexternalfixator AT gudmundsdottirrakel isthereacorrelationbetweenfunctionalresultsandradiographicfindingsinpatientswithdistalradiusfracturea0typea3treatedwithvolarlockingplateorexternalfixator AT krukhaugyngvar isthereacorrelationbetweenfunctionalresultsandradiographicfindingsinpatientswithdistalradiusfracturea0typea3treatedwithvolarlockingplateorexternalfixator AT dybvikeva isthereacorrelationbetweenfunctionalresultsandradiographicfindingsinpatientswithdistalradiusfracturea0typea3treatedwithvolarlockingplateorexternalfixator AT fevangjonasmeling isthereacorrelationbetweenfunctionalresultsandradiographicfindingsinpatientswithdistalradiusfracturea0typea3treatedwithvolarlockingplateorexternalfixator |