Cargando…

A systematic review of the use of titanium versus stainless steel implants for fracture fixation

BACKGROUND: Controversy exists regarding the use of titanium and stainless steel implants in fracture surgery. To our knowledge, no recent, comprehensive review on this topic has been reported. PURPOSE: To perform a systematic review of the evidence in the current literature comparing differences be...

Descripción completa

Detalles Bibliográficos
Autores principales: Barber, Collin C., Burnham, Matthew, Ojameruaye, Ogaga, McKee, Michael D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8568430/
https://www.ncbi.nlm.nih.gov/pubmed/34746670
http://dx.doi.org/10.1097/OI9.0000000000000138
_version_ 1784594437001707520
author Barber, Collin C.
Burnham, Matthew
Ojameruaye, Ogaga
McKee, Michael D.
author_facet Barber, Collin C.
Burnham, Matthew
Ojameruaye, Ogaga
McKee, Michael D.
author_sort Barber, Collin C.
collection PubMed
description BACKGROUND: Controversy exists regarding the use of titanium and stainless steel implants in fracture surgery. To our knowledge, no recent, comprehensive review on this topic has been reported. PURPOSE: To perform a systematic review of the evidence in the current literature comparing differences between titanium and stainless steel implants for fracture fixation. METHODS: A systematic review of original research articles was performed through the PubMed database using PRISMA guidelines. Inclusion criteria were English-language studies comparing titanium and stainless steel implants in orthopaedic surgery, and outcome data were extracted. RESULTS: The search returned 938 studies, with 37 studies meeting our criteria. There were 12 clinical research articles performed using human subjects, 11 animal studies, and 14 biomechanical studies. Clinical studies of the distal femur showed the stainless steel cohorts had significantly decreased callus formation and an increased odds radio (OR 6.3, 2.7-15.1; P < .001) of nonunion when compared with the titanium plate cohorts. In the distal radius, 3 clinical trials showed no implant failures in either group, and no difference in incidence of plate removal, or functional outcome. Three clinical studies showed a slightly increased odds ratio of locking screw breakage with stainless steel intramedullary nails compared with titanium intramedullary nails (OR 1.52, CI 1.1-2.13). CONCLUSION: Stainless steel implants have equal or superior biomechanical properties when compared with titanium implants. However, there is clinical evidence that titanium plates have a lower rate of failure and fewer complications than similar stainless steel implants in some situations. Although our review supports the use of titanium implants in these clinical scenarios, we emphasize that further prospective, comparative clinical studies are required before the conclusions can be made.
format Online
Article
Text
id pubmed-8568430
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-85684302021-11-05 A systematic review of the use of titanium versus stainless steel implants for fracture fixation Barber, Collin C. Burnham, Matthew Ojameruaye, Ogaga McKee, Michael D. OTA Int Systematic Review Article BACKGROUND: Controversy exists regarding the use of titanium and stainless steel implants in fracture surgery. To our knowledge, no recent, comprehensive review on this topic has been reported. PURPOSE: To perform a systematic review of the evidence in the current literature comparing differences between titanium and stainless steel implants for fracture fixation. METHODS: A systematic review of original research articles was performed through the PubMed database using PRISMA guidelines. Inclusion criteria were English-language studies comparing titanium and stainless steel implants in orthopaedic surgery, and outcome data were extracted. RESULTS: The search returned 938 studies, with 37 studies meeting our criteria. There were 12 clinical research articles performed using human subjects, 11 animal studies, and 14 biomechanical studies. Clinical studies of the distal femur showed the stainless steel cohorts had significantly decreased callus formation and an increased odds radio (OR 6.3, 2.7-15.1; P < .001) of nonunion when compared with the titanium plate cohorts. In the distal radius, 3 clinical trials showed no implant failures in either group, and no difference in incidence of plate removal, or functional outcome. Three clinical studies showed a slightly increased odds ratio of locking screw breakage with stainless steel intramedullary nails compared with titanium intramedullary nails (OR 1.52, CI 1.1-2.13). CONCLUSION: Stainless steel implants have equal or superior biomechanical properties when compared with titanium implants. However, there is clinical evidence that titanium plates have a lower rate of failure and fewer complications than similar stainless steel implants in some situations. Although our review supports the use of titanium implants in these clinical scenarios, we emphasize that further prospective, comparative clinical studies are required before the conclusions can be made. Lippincott Williams & Wilkins 2021-08-18 /pmc/articles/PMC8568430/ /pubmed/34746670 http://dx.doi.org/10.1097/OI9.0000000000000138 Text en Copyright © 2021 The Authors. Published by Wolters Kluwer Health, Inc. on behalf of the Orthopaedic Trauma Association. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Systematic Review Article
Barber, Collin C.
Burnham, Matthew
Ojameruaye, Ogaga
McKee, Michael D.
A systematic review of the use of titanium versus stainless steel implants for fracture fixation
title A systematic review of the use of titanium versus stainless steel implants for fracture fixation
title_full A systematic review of the use of titanium versus stainless steel implants for fracture fixation
title_fullStr A systematic review of the use of titanium versus stainless steel implants for fracture fixation
title_full_unstemmed A systematic review of the use of titanium versus stainless steel implants for fracture fixation
title_short A systematic review of the use of titanium versus stainless steel implants for fracture fixation
title_sort systematic review of the use of titanium versus stainless steel implants for fracture fixation
topic Systematic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8568430/
https://www.ncbi.nlm.nih.gov/pubmed/34746670
http://dx.doi.org/10.1097/OI9.0000000000000138
work_keys_str_mv AT barbercollinc asystematicreviewoftheuseoftitaniumversusstainlesssteelimplantsforfracturefixation
AT burnhammatthew asystematicreviewoftheuseoftitaniumversusstainlesssteelimplantsforfracturefixation
AT ojameruayeogaga asystematicreviewoftheuseoftitaniumversusstainlesssteelimplantsforfracturefixation
AT mckeemichaeld asystematicreviewoftheuseoftitaniumversusstainlesssteelimplantsforfracturefixation
AT barbercollinc systematicreviewoftheuseoftitaniumversusstainlesssteelimplantsforfracturefixation
AT burnhammatthew systematicreviewoftheuseoftitaniumversusstainlesssteelimplantsforfracturefixation
AT ojameruayeogaga systematicreviewoftheuseoftitaniumversusstainlesssteelimplantsforfracturefixation
AT mckeemichaeld systematicreviewoftheuseoftitaniumversusstainlesssteelimplantsforfracturefixation