Invertibility of multi‐energy X‐ray transform
PURPOSE: The goal is to provide a sufficient condition for the invertibility of a multi‐energy (ME) X‐ray transform. The energy‐dependent X‐ray attenuation profiles can be represented by a set of coefficients using the Alvarez–Macovski (AM) method. An ME X‐ray transform is a mapping from [Formula: s...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8568641/ https://www.ncbi.nlm.nih.gov/pubmed/34390587 http://dx.doi.org/10.1002/mp.15168 |
_version_ | 1784594482783584256 |
---|---|
author | Ding, Yijun Clarkson, Eric W. Ashok, Amit |
author_facet | Ding, Yijun Clarkson, Eric W. Ashok, Amit |
author_sort | Ding, Yijun |
collection | PubMed |
description | PURPOSE: The goal is to provide a sufficient condition for the invertibility of a multi‐energy (ME) X‐ray transform. The energy‐dependent X‐ray attenuation profiles can be represented by a set of coefficients using the Alvarez–Macovski (AM) method. An ME X‐ray transform is a mapping from [Formula: see text] AM coefficients to [Formula: see text] noise‐free energy‐weighted measurements, where [Formula: see text]. METHODS: We apply a general invertibility theorem to prove the equivalence of global and local invertibility for an ME X‐ray transform. We explore the global invertibility through testing whether the Jacobian of the mapping [Formula: see text] has zero values over the support of the mapping. The Jacobian of an arbitrary ME X‐ray transform is an integration over all spectral measurements. A sufficient condition for [Formula: see text] for all [Formula: see text] is that the integrand of [Formula: see text] is [Formula: see text] (or [Formula: see text]) everywhere. Note that the trivial case of the integrand equals 0 everywhere is ignored. Using symmetry, we simplified the integrand of the Jacobian to three factors that are determined by the total attenuation, the basis functions, and the energy‐weighting functions, respectively. The factor related to the total attenuation is always positive; hence, the invertibility of the X‐ray transform can be determined by testing the signs of the other two factors. Furthermore, we use the Cramér–Rao lower bound (CRLB) to characterize the noise‐induced estimation uncertainty and provide a maximum‐likelihood (ML) estimator. RESULTS: The factor related to the basis functions is always negative when the photoelectric/Compton/Rayleigh basis functions are used and K‐edge materials are not considered. The sign of the energy‐weighting factor depends on the system source spectra and the detector response functions. For four special types of X‐ray detectors, the sign of this factor stays the same over the integration range. Therefore, when these four types of detectors are used for imaging non‐K‐edge materials, the ME X‐ray transform is globally invertible. The same framework can be used to study an arbitrary ME X‐ray imaging system, for example, when K‐edge materials are present. Furthermore, the ML estimator we presented is an unbiased, efficient estimator and can be used for a wide range of scenes. CONCLUSIONS: We have provided a framework to study the invertibility of an arbitrary ME X‐ray transform and proved the global invertibility for four types of systems. |
format | Online Article Text |
id | pubmed-8568641 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-85686412022-10-01 Invertibility of multi‐energy X‐ray transform Ding, Yijun Clarkson, Eric W. Ashok, Amit Med Phys QUANTITATIVE IMAGING AND IMAGE PROCESSING PURPOSE: The goal is to provide a sufficient condition for the invertibility of a multi‐energy (ME) X‐ray transform. The energy‐dependent X‐ray attenuation profiles can be represented by a set of coefficients using the Alvarez–Macovski (AM) method. An ME X‐ray transform is a mapping from [Formula: see text] AM coefficients to [Formula: see text] noise‐free energy‐weighted measurements, where [Formula: see text]. METHODS: We apply a general invertibility theorem to prove the equivalence of global and local invertibility for an ME X‐ray transform. We explore the global invertibility through testing whether the Jacobian of the mapping [Formula: see text] has zero values over the support of the mapping. The Jacobian of an arbitrary ME X‐ray transform is an integration over all spectral measurements. A sufficient condition for [Formula: see text] for all [Formula: see text] is that the integrand of [Formula: see text] is [Formula: see text] (or [Formula: see text]) everywhere. Note that the trivial case of the integrand equals 0 everywhere is ignored. Using symmetry, we simplified the integrand of the Jacobian to three factors that are determined by the total attenuation, the basis functions, and the energy‐weighting functions, respectively. The factor related to the total attenuation is always positive; hence, the invertibility of the X‐ray transform can be determined by testing the signs of the other two factors. Furthermore, we use the Cramér–Rao lower bound (CRLB) to characterize the noise‐induced estimation uncertainty and provide a maximum‐likelihood (ML) estimator. RESULTS: The factor related to the basis functions is always negative when the photoelectric/Compton/Rayleigh basis functions are used and K‐edge materials are not considered. The sign of the energy‐weighting factor depends on the system source spectra and the detector response functions. For four special types of X‐ray detectors, the sign of this factor stays the same over the integration range. Therefore, when these four types of detectors are used for imaging non‐K‐edge materials, the ME X‐ray transform is globally invertible. The same framework can be used to study an arbitrary ME X‐ray imaging system, for example, when K‐edge materials are present. Furthermore, the ML estimator we presented is an unbiased, efficient estimator and can be used for a wide range of scenes. CONCLUSIONS: We have provided a framework to study the invertibility of an arbitrary ME X‐ray transform and proved the global invertibility for four types of systems. John Wiley and Sons Inc. 2021-08-26 2021-10 /pmc/articles/PMC8568641/ /pubmed/34390587 http://dx.doi.org/10.1002/mp.15168 Text en © 2021 The Authors. Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | QUANTITATIVE IMAGING AND IMAGE PROCESSING Ding, Yijun Clarkson, Eric W. Ashok, Amit Invertibility of multi‐energy X‐ray transform |
title | Invertibility of multi‐energy X‐ray transform |
title_full | Invertibility of multi‐energy X‐ray transform |
title_fullStr | Invertibility of multi‐energy X‐ray transform |
title_full_unstemmed | Invertibility of multi‐energy X‐ray transform |
title_short | Invertibility of multi‐energy X‐ray transform |
title_sort | invertibility of multi‐energy x‐ray transform |
topic | QUANTITATIVE IMAGING AND IMAGE PROCESSING |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8568641/ https://www.ncbi.nlm.nih.gov/pubmed/34390587 http://dx.doi.org/10.1002/mp.15168 |
work_keys_str_mv | AT dingyijun invertibilityofmultienergyxraytransform AT clarksonericw invertibilityofmultienergyxraytransform AT ashokamit invertibilityofmultienergyxraytransform |