Invertibility of multi‐energy X‐ray transform

PURPOSE: The goal is to provide a sufficient condition for the invertibility of a multi‐energy (ME) X‐ray transform. The energy‐dependent X‐ray attenuation profiles can be represented by a set of coefficients using the Alvarez–Macovski (AM) method. An ME X‐ray transform is a mapping from [Formula: s...

Descripción completa

Detalles Bibliográficos
Autores principales: Ding, Yijun, Clarkson, Eric W., Ashok, Amit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8568641/
https://www.ncbi.nlm.nih.gov/pubmed/34390587
http://dx.doi.org/10.1002/mp.15168
_version_ 1784594482783584256
author Ding, Yijun
Clarkson, Eric W.
Ashok, Amit
author_facet Ding, Yijun
Clarkson, Eric W.
Ashok, Amit
author_sort Ding, Yijun
collection PubMed
description PURPOSE: The goal is to provide a sufficient condition for the invertibility of a multi‐energy (ME) X‐ray transform. The energy‐dependent X‐ray attenuation profiles can be represented by a set of coefficients using the Alvarez–Macovski (AM) method. An ME X‐ray transform is a mapping from [Formula: see text] AM coefficients to [Formula: see text] noise‐free energy‐weighted measurements, where [Formula: see text]. METHODS: We apply a general invertibility theorem to prove the equivalence of global and local invertibility for an ME X‐ray transform. We explore the global invertibility through testing whether the Jacobian of the mapping [Formula: see text] has zero values over the support of the mapping. The Jacobian of an arbitrary ME X‐ray transform is an integration over all spectral measurements. A sufficient condition for [Formula: see text] for all [Formula: see text] is that the integrand of [Formula: see text] is [Formula: see text] (or [Formula: see text]) everywhere. Note that the trivial case of the integrand equals 0 everywhere is ignored. Using symmetry, we simplified the integrand of the Jacobian to three factors that are determined by the total attenuation, the basis functions, and the energy‐weighting functions, respectively. The factor related to the total attenuation is always positive; hence, the invertibility of the X‐ray transform can be determined by testing the signs of the other two factors. Furthermore, we use the Cramér–Rao lower bound (CRLB) to characterize the noise‐induced estimation uncertainty and provide a maximum‐likelihood (ML) estimator. RESULTS: The factor related to the basis functions is always negative when the photoelectric/Compton/Rayleigh basis functions are used and K‐edge materials are not considered. The sign of the energy‐weighting factor depends on the system source spectra and the detector response functions. For four special types of X‐ray detectors, the sign of this factor stays the same over the integration range. Therefore, when these four types of detectors are used for imaging non‐K‐edge materials, the ME X‐ray transform is globally invertible. The same framework can be used to study an arbitrary ME X‐ray imaging system, for example, when K‐edge materials are present. Furthermore, the ML estimator we presented is an unbiased, efficient estimator and can be used for a wide range of scenes. CONCLUSIONS: We have provided a framework to study the invertibility of an arbitrary ME X‐ray transform and proved the global invertibility for four types of systems.
format Online
Article
Text
id pubmed-8568641
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-85686412022-10-01 Invertibility of multi‐energy X‐ray transform Ding, Yijun Clarkson, Eric W. Ashok, Amit Med Phys QUANTITATIVE IMAGING AND IMAGE PROCESSING PURPOSE: The goal is to provide a sufficient condition for the invertibility of a multi‐energy (ME) X‐ray transform. The energy‐dependent X‐ray attenuation profiles can be represented by a set of coefficients using the Alvarez–Macovski (AM) method. An ME X‐ray transform is a mapping from [Formula: see text] AM coefficients to [Formula: see text] noise‐free energy‐weighted measurements, where [Formula: see text]. METHODS: We apply a general invertibility theorem to prove the equivalence of global and local invertibility for an ME X‐ray transform. We explore the global invertibility through testing whether the Jacobian of the mapping [Formula: see text] has zero values over the support of the mapping. The Jacobian of an arbitrary ME X‐ray transform is an integration over all spectral measurements. A sufficient condition for [Formula: see text] for all [Formula: see text] is that the integrand of [Formula: see text] is [Formula: see text] (or [Formula: see text]) everywhere. Note that the trivial case of the integrand equals 0 everywhere is ignored. Using symmetry, we simplified the integrand of the Jacobian to three factors that are determined by the total attenuation, the basis functions, and the energy‐weighting functions, respectively. The factor related to the total attenuation is always positive; hence, the invertibility of the X‐ray transform can be determined by testing the signs of the other two factors. Furthermore, we use the Cramér–Rao lower bound (CRLB) to characterize the noise‐induced estimation uncertainty and provide a maximum‐likelihood (ML) estimator. RESULTS: The factor related to the basis functions is always negative when the photoelectric/Compton/Rayleigh basis functions are used and K‐edge materials are not considered. The sign of the energy‐weighting factor depends on the system source spectra and the detector response functions. For four special types of X‐ray detectors, the sign of this factor stays the same over the integration range. Therefore, when these four types of detectors are used for imaging non‐K‐edge materials, the ME X‐ray transform is globally invertible. The same framework can be used to study an arbitrary ME X‐ray imaging system, for example, when K‐edge materials are present. Furthermore, the ML estimator we presented is an unbiased, efficient estimator and can be used for a wide range of scenes. CONCLUSIONS: We have provided a framework to study the invertibility of an arbitrary ME X‐ray transform and proved the global invertibility for four types of systems. John Wiley and Sons Inc. 2021-08-26 2021-10 /pmc/articles/PMC8568641/ /pubmed/34390587 http://dx.doi.org/10.1002/mp.15168 Text en © 2021 The Authors. Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle QUANTITATIVE IMAGING AND IMAGE PROCESSING
Ding, Yijun
Clarkson, Eric W.
Ashok, Amit
Invertibility of multi‐energy X‐ray transform
title Invertibility of multi‐energy X‐ray transform
title_full Invertibility of multi‐energy X‐ray transform
title_fullStr Invertibility of multi‐energy X‐ray transform
title_full_unstemmed Invertibility of multi‐energy X‐ray transform
title_short Invertibility of multi‐energy X‐ray transform
title_sort invertibility of multi‐energy x‐ray transform
topic QUANTITATIVE IMAGING AND IMAGE PROCESSING
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8568641/
https://www.ncbi.nlm.nih.gov/pubmed/34390587
http://dx.doi.org/10.1002/mp.15168
work_keys_str_mv AT dingyijun invertibilityofmultienergyxraytransform
AT clarksonericw invertibilityofmultienergyxraytransform
AT ashokamit invertibilityofmultienergyxraytransform