Cargando…

Fast wide-field upconversion luminescence lifetime thermometry enabled by single-shot compressed ultrahigh-speed imaging

Photoluminescence lifetime imaging of upconverting nanoparticles is increasingly featured in recent progress in optical thermometry. Despite remarkable advances in photoluminescent temperature indicators, existing optical instruments lack the ability of wide-field photoluminescence lifetime imaging...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Xianglei, Skripka, Artiom, Lai, Yingming, Jiang, Cheng, Liu, Jingdan, Vetrone, Fiorenzo, Liang, Jinyang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8568918/
https://www.ncbi.nlm.nih.gov/pubmed/34737314
http://dx.doi.org/10.1038/s41467-021-26701-1
_version_ 1784594534336823296
author Liu, Xianglei
Skripka, Artiom
Lai, Yingming
Jiang, Cheng
Liu, Jingdan
Vetrone, Fiorenzo
Liang, Jinyang
author_facet Liu, Xianglei
Skripka, Artiom
Lai, Yingming
Jiang, Cheng
Liu, Jingdan
Vetrone, Fiorenzo
Liang, Jinyang
author_sort Liu, Xianglei
collection PubMed
description Photoluminescence lifetime imaging of upconverting nanoparticles is increasingly featured in recent progress in optical thermometry. Despite remarkable advances in photoluminescent temperature indicators, existing optical instruments lack the ability of wide-field photoluminescence lifetime imaging in real time, thus falling short in dynamic temperature mapping. Here, we report video-rate upconversion temperature sensing in wide field using single-shot photoluminescence lifetime imaging thermometry (SPLIT). Developed from a compressed-sensing ultrahigh-speed imaging paradigm, SPLIT first records wide-field luminescence intensity decay compressively in two views in a single exposure. Then, an algorithm, built upon the plug-and-play alternating direction method of multipliers, is used to reconstruct the video, from which the extracted lifetime distribution is converted to a temperature map. Using the core/shell NaGdF(4):Er(3+),Yb(3+)/NaGdF(4) upconverting nanoparticles as the lifetime-based temperature indicators, we apply SPLIT in longitudinal wide-field temperature monitoring beneath a thin scattering medium. SPLIT also enables video-rate temperature mapping of a moving biological sample at single-cell resolution.
format Online
Article
Text
id pubmed-8568918
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-85689182021-11-15 Fast wide-field upconversion luminescence lifetime thermometry enabled by single-shot compressed ultrahigh-speed imaging Liu, Xianglei Skripka, Artiom Lai, Yingming Jiang, Cheng Liu, Jingdan Vetrone, Fiorenzo Liang, Jinyang Nat Commun Article Photoluminescence lifetime imaging of upconverting nanoparticles is increasingly featured in recent progress in optical thermometry. Despite remarkable advances in photoluminescent temperature indicators, existing optical instruments lack the ability of wide-field photoluminescence lifetime imaging in real time, thus falling short in dynamic temperature mapping. Here, we report video-rate upconversion temperature sensing in wide field using single-shot photoluminescence lifetime imaging thermometry (SPLIT). Developed from a compressed-sensing ultrahigh-speed imaging paradigm, SPLIT first records wide-field luminescence intensity decay compressively in two views in a single exposure. Then, an algorithm, built upon the plug-and-play alternating direction method of multipliers, is used to reconstruct the video, from which the extracted lifetime distribution is converted to a temperature map. Using the core/shell NaGdF(4):Er(3+),Yb(3+)/NaGdF(4) upconverting nanoparticles as the lifetime-based temperature indicators, we apply SPLIT in longitudinal wide-field temperature monitoring beneath a thin scattering medium. SPLIT also enables video-rate temperature mapping of a moving biological sample at single-cell resolution. Nature Publishing Group UK 2021-11-04 /pmc/articles/PMC8568918/ /pubmed/34737314 http://dx.doi.org/10.1038/s41467-021-26701-1 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Liu, Xianglei
Skripka, Artiom
Lai, Yingming
Jiang, Cheng
Liu, Jingdan
Vetrone, Fiorenzo
Liang, Jinyang
Fast wide-field upconversion luminescence lifetime thermometry enabled by single-shot compressed ultrahigh-speed imaging
title Fast wide-field upconversion luminescence lifetime thermometry enabled by single-shot compressed ultrahigh-speed imaging
title_full Fast wide-field upconversion luminescence lifetime thermometry enabled by single-shot compressed ultrahigh-speed imaging
title_fullStr Fast wide-field upconversion luminescence lifetime thermometry enabled by single-shot compressed ultrahigh-speed imaging
title_full_unstemmed Fast wide-field upconversion luminescence lifetime thermometry enabled by single-shot compressed ultrahigh-speed imaging
title_short Fast wide-field upconversion luminescence lifetime thermometry enabled by single-shot compressed ultrahigh-speed imaging
title_sort fast wide-field upconversion luminescence lifetime thermometry enabled by single-shot compressed ultrahigh-speed imaging
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8568918/
https://www.ncbi.nlm.nih.gov/pubmed/34737314
http://dx.doi.org/10.1038/s41467-021-26701-1
work_keys_str_mv AT liuxianglei fastwidefieldupconversionluminescencelifetimethermometryenabledbysingleshotcompressedultrahighspeedimaging
AT skripkaartiom fastwidefieldupconversionluminescencelifetimethermometryenabledbysingleshotcompressedultrahighspeedimaging
AT laiyingming fastwidefieldupconversionluminescencelifetimethermometryenabledbysingleshotcompressedultrahighspeedimaging
AT jiangcheng fastwidefieldupconversionluminescencelifetimethermometryenabledbysingleshotcompressedultrahighspeedimaging
AT liujingdan fastwidefieldupconversionluminescencelifetimethermometryenabledbysingleshotcompressedultrahighspeedimaging
AT vetronefiorenzo fastwidefieldupconversionluminescencelifetimethermometryenabledbysingleshotcompressedultrahighspeedimaging
AT liangjinyang fastwidefieldupconversionluminescencelifetimethermometryenabledbysingleshotcompressedultrahighspeedimaging