The performance and parameters of the online photon single-shot spectrometer (PSSS) at the Aramis beamline of the SwissFEL free-electron laser are presented. The device operates between the photon energies 4 and 13 keV and uses diamond transmission gratings and bent Si crystals for spectral measurem...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Union of Crystallography
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8570208/ https://www.ncbi.nlm.nih.gov/pubmed/34738953 http://dx.doi.org/10.1107/S1600577521009619 |
_version_ | 1784594795313758208 |
---|---|
author | David, Christian Seniutinas, Gediminas Makita, Mikako Rösner, Benedikt Rehanek, Jens Karvinen, Petri Löhl, Florian Abela, Rafael Patthey, Luc Juranić, Pavle |
author_facet | David, Christian Seniutinas, Gediminas Makita, Mikako Rösner, Benedikt Rehanek, Jens Karvinen, Petri Löhl, Florian Abela, Rafael Patthey, Luc Juranić, Pavle |
author_sort | David, Christian |
collection | PubMed |
description | The performance and parameters of the online photon single-shot spectrometer (PSSS) at the Aramis beamline of the SwissFEL free-electron laser are presented. The device operates between the photon energies 4 and 13 keV and uses diamond transmission gratings and bent Si crystals for spectral measurements on the first diffraction order of the beam. The device has an energy window of 0.7% of the median photon energy of the free-electron laser pulses and a spectral resolution (full width at half-maximum) ΔE/E on the order of 10(−5). The device was characterized by comparing its performance with reference data from synchrotron sources, and a parametric study investigated other effects that could affect the reliability of the spectral information. |
format | Online Article Text |
id | pubmed-8570208 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | International Union of Crystallography |
record_format | MEDLINE/PubMed |
spelling | pubmed-85702082021-11-18 Spectral monitoring at SwissFEL using a high-resolution on-line hard X-ray single-shot spectrometer David, Christian Seniutinas, Gediminas Makita, Mikako Rösner, Benedikt Rehanek, Jens Karvinen, Petri Löhl, Florian Abela, Rafael Patthey, Luc Juranić, Pavle J Synchrotron Radiat Beamlines The performance and parameters of the online photon single-shot spectrometer (PSSS) at the Aramis beamline of the SwissFEL free-electron laser are presented. The device operates between the photon energies 4 and 13 keV and uses diamond transmission gratings and bent Si crystals for spectral measurements on the first diffraction order of the beam. The device has an energy window of 0.7% of the median photon energy of the free-electron laser pulses and a spectral resolution (full width at half-maximum) ΔE/E on the order of 10(−5). The device was characterized by comparing its performance with reference data from synchrotron sources, and a parametric study investigated other effects that could affect the reliability of the spectral information. International Union of Crystallography 2021-10-21 /pmc/articles/PMC8570208/ /pubmed/34738953 http://dx.doi.org/10.1107/S1600577521009619 Text en © Christian David et al. 2021 https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited. |
spellingShingle | Beamlines David, Christian Seniutinas, Gediminas Makita, Mikako Rösner, Benedikt Rehanek, Jens Karvinen, Petri Löhl, Florian Abela, Rafael Patthey, Luc Juranić, Pavle Spectral monitoring at SwissFEL using a high-resolution on-line hard X-ray single-shot spectrometer |
title | Spectral monitoring at SwissFEL using a high-resolution on-line hard X-ray single-shot spectrometer |
title_full | Spectral monitoring at SwissFEL using a high-resolution on-line hard X-ray single-shot spectrometer |
title_fullStr | Spectral monitoring at SwissFEL using a high-resolution on-line hard X-ray single-shot spectrometer |
title_full_unstemmed | Spectral monitoring at SwissFEL using a high-resolution on-line hard X-ray single-shot spectrometer |
title_short | Spectral monitoring at SwissFEL using a high-resolution on-line hard X-ray single-shot spectrometer |
title_sort | spectral monitoring at swissfel using a high-resolution on-line hard x-ray single-shot spectrometer |
topic | Beamlines |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8570208/ https://www.ncbi.nlm.nih.gov/pubmed/34738953 http://dx.doi.org/10.1107/S1600577521009619 |
work_keys_str_mv | AT davidchristian spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer AT seniutinasgediminas spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer AT makitamikako spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer AT rosnerbenedikt spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer AT rehanekjens spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer AT karvinenpetri spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer AT lohlflorian spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer AT abelarafael spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer AT pattheyluc spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer AT juranicpavle spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer |