Cargando…

Spectral monitoring at SwissFEL using a high-resolution on-line hard X-ray single-shot spectrometer

The performance and parameters of the online photon single-shot spectrometer (PSSS) at the Aramis beamline of the SwissFEL free-electron laser are presented. The device operates between the photon energies 4 and 13 keV and uses diamond transmission gratings and bent Si crystals for spectral measurem...

Descripción completa

Detalles Bibliográficos
Autores principales: David, Christian, Seniutinas, Gediminas, Makita, Mikako, Rösner, Benedikt, Rehanek, Jens, Karvinen, Petri, Löhl, Florian, Abela, Rafael, Patthey, Luc, Juranić, Pavle
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Union of Crystallography 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8570208/
https://www.ncbi.nlm.nih.gov/pubmed/34738953
http://dx.doi.org/10.1107/S1600577521009619
_version_ 1784594795313758208
author David, Christian
Seniutinas, Gediminas
Makita, Mikako
Rösner, Benedikt
Rehanek, Jens
Karvinen, Petri
Löhl, Florian
Abela, Rafael
Patthey, Luc
Juranić, Pavle
author_facet David, Christian
Seniutinas, Gediminas
Makita, Mikako
Rösner, Benedikt
Rehanek, Jens
Karvinen, Petri
Löhl, Florian
Abela, Rafael
Patthey, Luc
Juranić, Pavle
author_sort David, Christian
collection PubMed
description The performance and parameters of the online photon single-shot spectrometer (PSSS) at the Aramis beamline of the SwissFEL free-electron laser are presented. The device operates between the photon energies 4 and 13 keV and uses diamond transmission gratings and bent Si crystals for spectral measurements on the first diffraction order of the beam. The device has an energy window of 0.7% of the median photon energy of the free-electron laser pulses and a spectral resolution (full width at half-maximum) ΔE/E on the order of 10(−5). The device was characterized by comparing its performance with reference data from synchrotron sources, and a parametric study investigated other effects that could affect the reliability of the spectral information.
format Online
Article
Text
id pubmed-8570208
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher International Union of Crystallography
record_format MEDLINE/PubMed
spelling pubmed-85702082021-11-18 Spectral monitoring at SwissFEL using a high-resolution on-line hard X-ray single-shot spectrometer David, Christian Seniutinas, Gediminas Makita, Mikako Rösner, Benedikt Rehanek, Jens Karvinen, Petri Löhl, Florian Abela, Rafael Patthey, Luc Juranić, Pavle J Synchrotron Radiat Beamlines The performance and parameters of the online photon single-shot spectrometer (PSSS) at the Aramis beamline of the SwissFEL free-electron laser are presented. The device operates between the photon energies 4 and 13 keV and uses diamond transmission gratings and bent Si crystals for spectral measurements on the first diffraction order of the beam. The device has an energy window of 0.7% of the median photon energy of the free-electron laser pulses and a spectral resolution (full width at half-maximum) ΔE/E on the order of 10(−5). The device was characterized by comparing its performance with reference data from synchrotron sources, and a parametric study investigated other effects that could affect the reliability of the spectral information. International Union of Crystallography 2021-10-21 /pmc/articles/PMC8570208/ /pubmed/34738953 http://dx.doi.org/10.1107/S1600577521009619 Text en © Christian David et al. 2021 https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.
spellingShingle Beamlines
David, Christian
Seniutinas, Gediminas
Makita, Mikako
Rösner, Benedikt
Rehanek, Jens
Karvinen, Petri
Löhl, Florian
Abela, Rafael
Patthey, Luc
Juranić, Pavle
Spectral monitoring at SwissFEL using a high-resolution on-line hard X-ray single-shot spectrometer
title Spectral monitoring at SwissFEL using a high-resolution on-line hard X-ray single-shot spectrometer
title_full Spectral monitoring at SwissFEL using a high-resolution on-line hard X-ray single-shot spectrometer
title_fullStr Spectral monitoring at SwissFEL using a high-resolution on-line hard X-ray single-shot spectrometer
title_full_unstemmed Spectral monitoring at SwissFEL using a high-resolution on-line hard X-ray single-shot spectrometer
title_short Spectral monitoring at SwissFEL using a high-resolution on-line hard X-ray single-shot spectrometer
title_sort spectral monitoring at swissfel using a high-resolution on-line hard x-ray single-shot spectrometer
topic Beamlines
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8570208/
https://www.ncbi.nlm.nih.gov/pubmed/34738953
http://dx.doi.org/10.1107/S1600577521009619
work_keys_str_mv AT davidchristian spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer
AT seniutinasgediminas spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer
AT makitamikako spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer
AT rosnerbenedikt spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer
AT rehanekjens spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer
AT karvinenpetri spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer
AT lohlflorian spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer
AT abelarafael spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer
AT pattheyluc spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer
AT juranicpavle spectralmonitoringatswissfelusingahighresolutiononlinehardxraysingleshotspectrometer