Cargando…

The Environmental Deposition of Severe Acute Respiratory Syndrome Coronavirus 2 in Nosocomial Settings: Role of the Aerosolized Hydrogen Peroxide

BACKGROUND: Data on the role of aerosolized hydrogen peroxide (AHP) systems in the control of the COVID-19 pandemic are still emerging. This study provides evidence of the environmental shedding of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in the hospital environment, and the effi...

Descripción completa

Detalles Bibliográficos
Autores principales: Alnimr, Amani, Alamri, Aisha, Salama, Khaled F, Radi, Mahmoud, Bukharie, Huda, Alshehri, Bashayer, Rabaan, Ali A, Alshahrani, Mohammed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8570375/
https://www.ncbi.nlm.nih.gov/pubmed/34754253
http://dx.doi.org/10.2147/RMHP.S336085
_version_ 1784594826195369984
author Alnimr, Amani
Alamri, Aisha
Salama, Khaled F
Radi, Mahmoud
Bukharie, Huda
Alshehri, Bashayer
Rabaan, Ali A
Alshahrani, Mohammed
author_facet Alnimr, Amani
Alamri, Aisha
Salama, Khaled F
Radi, Mahmoud
Bukharie, Huda
Alshehri, Bashayer
Rabaan, Ali A
Alshahrani, Mohammed
author_sort Alnimr, Amani
collection PubMed
description BACKGROUND: Data on the role of aerosolized hydrogen peroxide (AHP) systems in the control of the COVID-19 pandemic are still emerging. This study provides evidence of the environmental shedding of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in the hospital environment, and the efficacy of AHP to eliminate it. METHODS: A total of 324 environmental sites (224 surfaces and 100 air samples) belonging to 54 patient rooms were contextually collected and tested for genes of SARS-CoV-2 using RT-PCR assays and Xpert(®) Xpress SARS-CoV-2. RESULTS: The SARS-CoV-2 viral genome was detected in seven sites (2.5%) of three patients’ rooms, including six highly touched surfaces and one air sample. Viral shedding was directly related to the distance from the patient, with 1, 1.9, and 3.5% of samples testing positive at 3, 2, and 1 meter, respectively (P-value=0.02). None of the sites showed the viral genome following application of 6% AHP. Of note, the viral genome was detected at 2 meters of a mildly symptomatic case on a face mask in the absence of aerosol generating procedures. CONCLUSION: Our data support the possible role of the hospital environment as a source of infection, and the efficacy of AHP to eliminate the virus. Further studies are needed to address the viability of the pathogen in these nosocomial sites and the cost-effectiveness of routine hospital disinfection procedures using AHP for SARS-CoV-2.
format Online
Article
Text
id pubmed-8570375
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-85703752021-11-08 The Environmental Deposition of Severe Acute Respiratory Syndrome Coronavirus 2 in Nosocomial Settings: Role of the Aerosolized Hydrogen Peroxide Alnimr, Amani Alamri, Aisha Salama, Khaled F Radi, Mahmoud Bukharie, Huda Alshehri, Bashayer Rabaan, Ali A Alshahrani, Mohammed Risk Manag Healthc Policy Original Research BACKGROUND: Data on the role of aerosolized hydrogen peroxide (AHP) systems in the control of the COVID-19 pandemic are still emerging. This study provides evidence of the environmental shedding of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in the hospital environment, and the efficacy of AHP to eliminate it. METHODS: A total of 324 environmental sites (224 surfaces and 100 air samples) belonging to 54 patient rooms were contextually collected and tested for genes of SARS-CoV-2 using RT-PCR assays and Xpert(®) Xpress SARS-CoV-2. RESULTS: The SARS-CoV-2 viral genome was detected in seven sites (2.5%) of three patients’ rooms, including six highly touched surfaces and one air sample. Viral shedding was directly related to the distance from the patient, with 1, 1.9, and 3.5% of samples testing positive at 3, 2, and 1 meter, respectively (P-value=0.02). None of the sites showed the viral genome following application of 6% AHP. Of note, the viral genome was detected at 2 meters of a mildly symptomatic case on a face mask in the absence of aerosol generating procedures. CONCLUSION: Our data support the possible role of the hospital environment as a source of infection, and the efficacy of AHP to eliminate the virus. Further studies are needed to address the viability of the pathogen in these nosocomial sites and the cost-effectiveness of routine hospital disinfection procedures using AHP for SARS-CoV-2. Dove 2021-11-01 /pmc/articles/PMC8570375/ /pubmed/34754253 http://dx.doi.org/10.2147/RMHP.S336085 Text en © 2021 Alnimr et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Alnimr, Amani
Alamri, Aisha
Salama, Khaled F
Radi, Mahmoud
Bukharie, Huda
Alshehri, Bashayer
Rabaan, Ali A
Alshahrani, Mohammed
The Environmental Deposition of Severe Acute Respiratory Syndrome Coronavirus 2 in Nosocomial Settings: Role of the Aerosolized Hydrogen Peroxide
title The Environmental Deposition of Severe Acute Respiratory Syndrome Coronavirus 2 in Nosocomial Settings: Role of the Aerosolized Hydrogen Peroxide
title_full The Environmental Deposition of Severe Acute Respiratory Syndrome Coronavirus 2 in Nosocomial Settings: Role of the Aerosolized Hydrogen Peroxide
title_fullStr The Environmental Deposition of Severe Acute Respiratory Syndrome Coronavirus 2 in Nosocomial Settings: Role of the Aerosolized Hydrogen Peroxide
title_full_unstemmed The Environmental Deposition of Severe Acute Respiratory Syndrome Coronavirus 2 in Nosocomial Settings: Role of the Aerosolized Hydrogen Peroxide
title_short The Environmental Deposition of Severe Acute Respiratory Syndrome Coronavirus 2 in Nosocomial Settings: Role of the Aerosolized Hydrogen Peroxide
title_sort environmental deposition of severe acute respiratory syndrome coronavirus 2 in nosocomial settings: role of the aerosolized hydrogen peroxide
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8570375/
https://www.ncbi.nlm.nih.gov/pubmed/34754253
http://dx.doi.org/10.2147/RMHP.S336085
work_keys_str_mv AT alnimramani theenvironmentaldepositionofsevereacuterespiratorysyndromecoronavirus2innosocomialsettingsroleoftheaerosolizedhydrogenperoxide
AT alamriaisha theenvironmentaldepositionofsevereacuterespiratorysyndromecoronavirus2innosocomialsettingsroleoftheaerosolizedhydrogenperoxide
AT salamakhaledf theenvironmentaldepositionofsevereacuterespiratorysyndromecoronavirus2innosocomialsettingsroleoftheaerosolizedhydrogenperoxide
AT radimahmoud theenvironmentaldepositionofsevereacuterespiratorysyndromecoronavirus2innosocomialsettingsroleoftheaerosolizedhydrogenperoxide
AT bukhariehuda theenvironmentaldepositionofsevereacuterespiratorysyndromecoronavirus2innosocomialsettingsroleoftheaerosolizedhydrogenperoxide
AT alshehribashayer theenvironmentaldepositionofsevereacuterespiratorysyndromecoronavirus2innosocomialsettingsroleoftheaerosolizedhydrogenperoxide
AT rabaanalia theenvironmentaldepositionofsevereacuterespiratorysyndromecoronavirus2innosocomialsettingsroleoftheaerosolizedhydrogenperoxide
AT alshahranimohammed theenvironmentaldepositionofsevereacuterespiratorysyndromecoronavirus2innosocomialsettingsroleoftheaerosolizedhydrogenperoxide
AT alnimramani environmentaldepositionofsevereacuterespiratorysyndromecoronavirus2innosocomialsettingsroleoftheaerosolizedhydrogenperoxide
AT alamriaisha environmentaldepositionofsevereacuterespiratorysyndromecoronavirus2innosocomialsettingsroleoftheaerosolizedhydrogenperoxide
AT salamakhaledf environmentaldepositionofsevereacuterespiratorysyndromecoronavirus2innosocomialsettingsroleoftheaerosolizedhydrogenperoxide
AT radimahmoud environmentaldepositionofsevereacuterespiratorysyndromecoronavirus2innosocomialsettingsroleoftheaerosolizedhydrogenperoxide
AT bukhariehuda environmentaldepositionofsevereacuterespiratorysyndromecoronavirus2innosocomialsettingsroleoftheaerosolizedhydrogenperoxide
AT alshehribashayer environmentaldepositionofsevereacuterespiratorysyndromecoronavirus2innosocomialsettingsroleoftheaerosolizedhydrogenperoxide
AT rabaanalia environmentaldepositionofsevereacuterespiratorysyndromecoronavirus2innosocomialsettingsroleoftheaerosolizedhydrogenperoxide
AT alshahranimohammed environmentaldepositionofsevereacuterespiratorysyndromecoronavirus2innosocomialsettingsroleoftheaerosolizedhydrogenperoxide