Visual outcomes and patient satisfaction 1 and 12 months after combined implantation of extended depth of focus and trifocal intraocular lenses

PURPOSE: To assess the 1-month and 12-month postoperative visual performance and subjective outcomes following combined implantation of an extended depth of focus (EDOF) intraocular lens (IOL) and a trifocal IOL. METHODS: The study enrolled consecutive patients undergoing refractive lens extraction...

Descripción completa

Detalles Bibliográficos
Autores principales: McNeely, Richard N., Moutari, Salissou, Stewart, Stephen, Moore, Jonathan E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8572828/
https://www.ncbi.nlm.nih.gov/pubmed/34546493
http://dx.doi.org/10.1007/s10792-021-01970-3
_version_ 1784595295633408000
author McNeely, Richard N.
Moutari, Salissou
Stewart, Stephen
Moore, Jonathan E.
author_facet McNeely, Richard N.
Moutari, Salissou
Stewart, Stephen
Moore, Jonathan E.
author_sort McNeely, Richard N.
collection PubMed
description PURPOSE: To assess the 1-month and 12-month postoperative visual performance and subjective outcomes following combined implantation of an extended depth of focus (EDOF) intraocular lens (IOL) and a trifocal IOL. METHODS: The study enrolled consecutive patients undergoing refractive lens extraction or cataract surgery with combined implantation of an EDOF IOL (dominant eye) and trifocal IOL. Uncorrected (UDVA) and best-corrected (CDVA) distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, and subjective questionnaires were evaluated 1 month and 12 months postoperatively. RESULTS: The study enrolled 58 consecutive patients. Binocular UDVA, UIVA and UNVA were − 0.08 ± 0.07 logMAR, 0.15 ± 0.14 logMAR and 0.17 ± 0.11 logMAR at 1 month, compared to − 0.09 ± 0.06 logMAR (P = .323), 0.11 ± 0.10 logMAR (P = .030) and 0.13 ± 0.10 logMAR (P = 0.008) at 12 months. Satisfaction was high with 93.1% of patients fulfilled or more than fulfilled postoperatively, and 84.5% and 86.3% reported spectacle independence for near at the respective postoperative assessments. The mean daytime and nighttime quality of vision (QoV) scores were 9.12 ± 0.94 and 7.88 ± 1.74 at 1 month, compared to 9.24 ± 0.78 (P = .183) and 8.26 ± 1.38 (P = .043) at 12 months. CONCLUSIONS: This IOL combination provides good unaided visual acuity at 1 and 12 months postoperatively, with high functional vision and postoperative satisfaction reported at 1 and 12 months. However, a significant improvement in overall nighttime QoV at the 12 months assessment was found.
format Online
Article
Text
id pubmed-8572828
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-85728282021-11-15 Visual outcomes and patient satisfaction 1 and 12 months after combined implantation of extended depth of focus and trifocal intraocular lenses McNeely, Richard N. Moutari, Salissou Stewart, Stephen Moore, Jonathan E. Int Ophthalmol Original Paper PURPOSE: To assess the 1-month and 12-month postoperative visual performance and subjective outcomes following combined implantation of an extended depth of focus (EDOF) intraocular lens (IOL) and a trifocal IOL. METHODS: The study enrolled consecutive patients undergoing refractive lens extraction or cataract surgery with combined implantation of an EDOF IOL (dominant eye) and trifocal IOL. Uncorrected (UDVA) and best-corrected (CDVA) distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, and subjective questionnaires were evaluated 1 month and 12 months postoperatively. RESULTS: The study enrolled 58 consecutive patients. Binocular UDVA, UIVA and UNVA were − 0.08 ± 0.07 logMAR, 0.15 ± 0.14 logMAR and 0.17 ± 0.11 logMAR at 1 month, compared to − 0.09 ± 0.06 logMAR (P = .323), 0.11 ± 0.10 logMAR (P = .030) and 0.13 ± 0.10 logMAR (P = 0.008) at 12 months. Satisfaction was high with 93.1% of patients fulfilled or more than fulfilled postoperatively, and 84.5% and 86.3% reported spectacle independence for near at the respective postoperative assessments. The mean daytime and nighttime quality of vision (QoV) scores were 9.12 ± 0.94 and 7.88 ± 1.74 at 1 month, compared to 9.24 ± 0.78 (P = .183) and 8.26 ± 1.38 (P = .043) at 12 months. CONCLUSIONS: This IOL combination provides good unaided visual acuity at 1 and 12 months postoperatively, with high functional vision and postoperative satisfaction reported at 1 and 12 months. However, a significant improvement in overall nighttime QoV at the 12 months assessment was found. Springer Netherlands 2021-09-21 2021 /pmc/articles/PMC8572828/ /pubmed/34546493 http://dx.doi.org/10.1007/s10792-021-01970-3 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Paper
McNeely, Richard N.
Moutari, Salissou
Stewart, Stephen
Moore, Jonathan E.
Visual outcomes and patient satisfaction 1 and 12 months after combined implantation of extended depth of focus and trifocal intraocular lenses
title Visual outcomes and patient satisfaction 1 and 12 months after combined implantation of extended depth of focus and trifocal intraocular lenses
title_full Visual outcomes and patient satisfaction 1 and 12 months after combined implantation of extended depth of focus and trifocal intraocular lenses
title_fullStr Visual outcomes and patient satisfaction 1 and 12 months after combined implantation of extended depth of focus and trifocal intraocular lenses
title_full_unstemmed Visual outcomes and patient satisfaction 1 and 12 months after combined implantation of extended depth of focus and trifocal intraocular lenses
title_short Visual outcomes and patient satisfaction 1 and 12 months after combined implantation of extended depth of focus and trifocal intraocular lenses
title_sort visual outcomes and patient satisfaction 1 and 12 months after combined implantation of extended depth of focus and trifocal intraocular lenses
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8572828/
https://www.ncbi.nlm.nih.gov/pubmed/34546493
http://dx.doi.org/10.1007/s10792-021-01970-3
work_keys_str_mv AT mcneelyrichardn visualoutcomesandpatientsatisfaction1and12monthsaftercombinedimplantationofextendeddepthoffocusandtrifocalintraocularlenses
AT moutarisalissou visualoutcomesandpatientsatisfaction1and12monthsaftercombinedimplantationofextendeddepthoffocusandtrifocalintraocularlenses
AT stewartstephen visualoutcomesandpatientsatisfaction1and12monthsaftercombinedimplantationofextendeddepthoffocusandtrifocalintraocularlenses
AT moorejonathane visualoutcomesandpatientsatisfaction1and12monthsaftercombinedimplantationofextendeddepthoffocusandtrifocalintraocularlenses