Cargando…
Baseline selection for evaluation of peri-implant soft tissue changes: a clinical trial
BACKGROUND: To select the optimal baseline for evaluation of peri-implant soft tissue changes among 1, 2, and 3 weeks after definitive crown insertion. METHODS: A total of 22 individuals who required implant restoration were recruited to this study. Each participant received a screw-retained convent...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AME Publishing Company
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8573432/ https://www.ncbi.nlm.nih.gov/pubmed/34805356 http://dx.doi.org/10.21037/atm-21-3335 |
_version_ | 1784595422353817600 |
---|---|
author | Zheng, Chaoling Wang, Shimin Ye, Hongqiang Liu, Yunsong Hu, Wenjie Zhou, Yongsheng |
author_facet | Zheng, Chaoling Wang, Shimin Ye, Hongqiang Liu, Yunsong Hu, Wenjie Zhou, Yongsheng |
author_sort | Zheng, Chaoling |
collection | PubMed |
description | BACKGROUND: To select the optimal baseline for evaluation of peri-implant soft tissue changes among 1, 2, and 3 weeks after definitive crown insertion. METHODS: A total of 22 individuals who required implant restoration were recruited to this study. Each participant received a screw-retained conventional implant restoration. Peri-implant soft tissue was captured by an intraoral scanner and analyzed by 3D analysis software. Soft tissue changes [mucosal margin (MM) and soft tissue thickness (STT)] on the buccal side of implant sites were evaluated at 1, 2, and 3 weeks after definitive crown insertion. One-way analysis of variance (ANOVA) for repeated measurement and Tukey’s test were used to analyze significant differences between the 3 time points (α=0.05). RESULTS: An increased volume of peri-implant soft tissue was observed shortly after definitive crown insertion. Based on the findings of peri-implant soft tissue changes, significant differences were observed between weeks 1 and 2 (P<0.01), and weeks 1 and 3 (P<0.01), while there was no significant difference between weeks 2 and 3 (P>0.05). CONCLUSIONS: Minimal peri-implant soft tissue changes occurred in this study. The time point of 2 weeks after definitive crown insertion was preliminarily selected as the baseline. The small sample size and few time points must be taken into consideration when interpreting these findings. TRIAL REGISTRATION: This study was retrospectively registered in the Chinese Clinical Trial Registry (Registration number: ChiCTR2000037954; Date of registration: 6 September 2020). |
format | Online Article Text |
id | pubmed-8573432 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | AME Publishing Company |
record_format | MEDLINE/PubMed |
spelling | pubmed-85734322021-11-18 Baseline selection for evaluation of peri-implant soft tissue changes: a clinical trial Zheng, Chaoling Wang, Shimin Ye, Hongqiang Liu, Yunsong Hu, Wenjie Zhou, Yongsheng Ann Transl Med Original Article BACKGROUND: To select the optimal baseline for evaluation of peri-implant soft tissue changes among 1, 2, and 3 weeks after definitive crown insertion. METHODS: A total of 22 individuals who required implant restoration were recruited to this study. Each participant received a screw-retained conventional implant restoration. Peri-implant soft tissue was captured by an intraoral scanner and analyzed by 3D analysis software. Soft tissue changes [mucosal margin (MM) and soft tissue thickness (STT)] on the buccal side of implant sites were evaluated at 1, 2, and 3 weeks after definitive crown insertion. One-way analysis of variance (ANOVA) for repeated measurement and Tukey’s test were used to analyze significant differences between the 3 time points (α=0.05). RESULTS: An increased volume of peri-implant soft tissue was observed shortly after definitive crown insertion. Based on the findings of peri-implant soft tissue changes, significant differences were observed between weeks 1 and 2 (P<0.01), and weeks 1 and 3 (P<0.01), while there was no significant difference between weeks 2 and 3 (P>0.05). CONCLUSIONS: Minimal peri-implant soft tissue changes occurred in this study. The time point of 2 weeks after definitive crown insertion was preliminarily selected as the baseline. The small sample size and few time points must be taken into consideration when interpreting these findings. TRIAL REGISTRATION: This study was retrospectively registered in the Chinese Clinical Trial Registry (Registration number: ChiCTR2000037954; Date of registration: 6 September 2020). AME Publishing Company 2021-10 /pmc/articles/PMC8573432/ /pubmed/34805356 http://dx.doi.org/10.21037/atm-21-3335 Text en 2021 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Original Article Zheng, Chaoling Wang, Shimin Ye, Hongqiang Liu, Yunsong Hu, Wenjie Zhou, Yongsheng Baseline selection for evaluation of peri-implant soft tissue changes: a clinical trial |
title | Baseline selection for evaluation of peri-implant soft tissue changes: a clinical trial |
title_full | Baseline selection for evaluation of peri-implant soft tissue changes: a clinical trial |
title_fullStr | Baseline selection for evaluation of peri-implant soft tissue changes: a clinical trial |
title_full_unstemmed | Baseline selection for evaluation of peri-implant soft tissue changes: a clinical trial |
title_short | Baseline selection for evaluation of peri-implant soft tissue changes: a clinical trial |
title_sort | baseline selection for evaluation of peri-implant soft tissue changes: a clinical trial |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8573432/ https://www.ncbi.nlm.nih.gov/pubmed/34805356 http://dx.doi.org/10.21037/atm-21-3335 |
work_keys_str_mv | AT zhengchaoling baselineselectionforevaluationofperiimplantsofttissuechangesaclinicaltrial AT wangshimin baselineselectionforevaluationofperiimplantsofttissuechangesaclinicaltrial AT yehongqiang baselineselectionforevaluationofperiimplantsofttissuechangesaclinicaltrial AT liuyunsong baselineselectionforevaluationofperiimplantsofttissuechangesaclinicaltrial AT huwenjie baselineselectionforevaluationofperiimplantsofttissuechangesaclinicaltrial AT zhouyongsheng baselineselectionforevaluationofperiimplantsofttissuechangesaclinicaltrial |