Cargando…

Multicenter Experience With Large Diameter Balloon-Expandable Stent-Grafts for the Treatment of Infrarenal Penetrating Aortic Ulcers

PURPOSE: To describe the use of large-diameter balloon-expandable stent-grafts (BeGraft aortic stent-graft, Bentley InnoMed GmbH, Hechingen, Germany) in the treatment of infrarenal penetrating aortic ulcer (iPAU). MATERIALS AND METHODS: Retrospective analysis of patients undergoing endovascular trea...

Descripción completa

Detalles Bibliográficos
Autores principales: Stana, Jan, Fernandez Prendes, Carlota, Kruszyna, Lukasz, Passaloglou, Ioannis Thomas, Ruffino, Maria Antonella, Reyes Valdivia, Andres, del Castro Madrazo, Jose Antonio, Oikonomou, Kyriakos, Chan, Hon Lai, Makaloski, Vladimir, Tsilimparis, Nikolaos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8573626/
https://www.ncbi.nlm.nih.gov/pubmed/34190634
http://dx.doi.org/10.1177/15266028211028221
_version_ 1784595467049369600
author Stana, Jan
Fernandez Prendes, Carlota
Kruszyna, Lukasz
Passaloglou, Ioannis Thomas
Ruffino, Maria Antonella
Reyes Valdivia, Andres
del Castro Madrazo, Jose Antonio
Oikonomou, Kyriakos
Chan, Hon Lai
Makaloski, Vladimir
Tsilimparis, Nikolaos
author_facet Stana, Jan
Fernandez Prendes, Carlota
Kruszyna, Lukasz
Passaloglou, Ioannis Thomas
Ruffino, Maria Antonella
Reyes Valdivia, Andres
del Castro Madrazo, Jose Antonio
Oikonomou, Kyriakos
Chan, Hon Lai
Makaloski, Vladimir
Tsilimparis, Nikolaos
author_sort Stana, Jan
collection PubMed
description PURPOSE: To describe the use of large-diameter balloon-expandable stent-grafts (BeGraft aortic stent-graft, Bentley InnoMed GmbH, Hechingen, Germany) in the treatment of infrarenal penetrating aortic ulcer (iPAU). MATERIALS AND METHODS: Retrospective analysis of patients undergoing endovascular treatment with the BeGraft aortic stent-graft in 8 European centers from January 2017 to October 2020. Demographics, perioperative data, and midterm outcomes were collected. Endpoints of the study were technical feasibility, early mortality, and morbidity. RESULTS: A total of 40 patients were included. The mean age was 73.9±7.05 years and 63.2% were male. Indications for treatment included size and morphology (65%), presence of symptoms (29.5%), and contained ruptures (5.5%). Urgent treatment was performed in 5% of cases. Technical success was 97.5%. Median operation time was 58 minutes (19–170 minutes), with 27.5% of patients having additional procedures during the main intervention (1 additional repair with a C-TAG (W.L. Gore & Associates, Inc, Flagstaff, AZ, USA) thoracic endoprosthesis, 5 covered endovascular reconstruction of aortic bifurcation procedures, 3 extensions with proximal cuffs, and 2 percutaneous angioplasties of the common iliac arteries). Percutaneous femoral access was used in 72.5%, while groin cut-down was performed in 27.5%. Repair was successful with only 1 stent in 45% of cases, while 37.5% required 2 stents and nearly 17.5% required 3/4 stent-grafts. The 30-day mortality was 0%, with a 2.5% reintervention rate (1 patient required evacuation of an intra-abdominal hematoma). Median follow-up was 13.9 months (2–39 months), during which no vascular-related reinterventions or deaths were reported. In 4 patients, a type II endoleak was observed. No cases of graft migration, thrombosis, or stent-fracture were observed. CONCLUSIONS: The treatment of iPAU with the BeGraft aortic stent-graft in a selective patient group is feasible with low rate of perioperative morbidity and mortality. Balloon-expandable stent-grafts offer the option to repair iPAUs with a shorter coverage of the aorta using low-profile sheath, that enables treatment in the presence of calcified access vessels and small diameter aortic bifurcations.
format Online
Article
Text
id pubmed-8573626
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-85736262021-11-09 Multicenter Experience With Large Diameter Balloon-Expandable Stent-Grafts for the Treatment of Infrarenal Penetrating Aortic Ulcers Stana, Jan Fernandez Prendes, Carlota Kruszyna, Lukasz Passaloglou, Ioannis Thomas Ruffino, Maria Antonella Reyes Valdivia, Andres del Castro Madrazo, Jose Antonio Oikonomou, Kyriakos Chan, Hon Lai Makaloski, Vladimir Tsilimparis, Nikolaos J Endovasc Ther Clinical Investigations PURPOSE: To describe the use of large-diameter balloon-expandable stent-grafts (BeGraft aortic stent-graft, Bentley InnoMed GmbH, Hechingen, Germany) in the treatment of infrarenal penetrating aortic ulcer (iPAU). MATERIALS AND METHODS: Retrospective analysis of patients undergoing endovascular treatment with the BeGraft aortic stent-graft in 8 European centers from January 2017 to October 2020. Demographics, perioperative data, and midterm outcomes were collected. Endpoints of the study were technical feasibility, early mortality, and morbidity. RESULTS: A total of 40 patients were included. The mean age was 73.9±7.05 years and 63.2% were male. Indications for treatment included size and morphology (65%), presence of symptoms (29.5%), and contained ruptures (5.5%). Urgent treatment was performed in 5% of cases. Technical success was 97.5%. Median operation time was 58 minutes (19–170 minutes), with 27.5% of patients having additional procedures during the main intervention (1 additional repair with a C-TAG (W.L. Gore & Associates, Inc, Flagstaff, AZ, USA) thoracic endoprosthesis, 5 covered endovascular reconstruction of aortic bifurcation procedures, 3 extensions with proximal cuffs, and 2 percutaneous angioplasties of the common iliac arteries). Percutaneous femoral access was used in 72.5%, while groin cut-down was performed in 27.5%. Repair was successful with only 1 stent in 45% of cases, while 37.5% required 2 stents and nearly 17.5% required 3/4 stent-grafts. The 30-day mortality was 0%, with a 2.5% reintervention rate (1 patient required evacuation of an intra-abdominal hematoma). Median follow-up was 13.9 months (2–39 months), during which no vascular-related reinterventions or deaths were reported. In 4 patients, a type II endoleak was observed. No cases of graft migration, thrombosis, or stent-fracture were observed. CONCLUSIONS: The treatment of iPAU with the BeGraft aortic stent-graft in a selective patient group is feasible with low rate of perioperative morbidity and mortality. Balloon-expandable stent-grafts offer the option to repair iPAUs with a shorter coverage of the aorta using low-profile sheath, that enables treatment in the presence of calcified access vessels and small diameter aortic bifurcations. SAGE Publications 2021-06-30 2021-12 /pmc/articles/PMC8573626/ /pubmed/34190634 http://dx.doi.org/10.1177/15266028211028221 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Clinical Investigations
Stana, Jan
Fernandez Prendes, Carlota
Kruszyna, Lukasz
Passaloglou, Ioannis Thomas
Ruffino, Maria Antonella
Reyes Valdivia, Andres
del Castro Madrazo, Jose Antonio
Oikonomou, Kyriakos
Chan, Hon Lai
Makaloski, Vladimir
Tsilimparis, Nikolaos
Multicenter Experience With Large Diameter Balloon-Expandable Stent-Grafts for the Treatment of Infrarenal Penetrating Aortic Ulcers
title Multicenter Experience With Large Diameter Balloon-Expandable Stent-Grafts for the Treatment of Infrarenal Penetrating Aortic Ulcers
title_full Multicenter Experience With Large Diameter Balloon-Expandable Stent-Grafts for the Treatment of Infrarenal Penetrating Aortic Ulcers
title_fullStr Multicenter Experience With Large Diameter Balloon-Expandable Stent-Grafts for the Treatment of Infrarenal Penetrating Aortic Ulcers
title_full_unstemmed Multicenter Experience With Large Diameter Balloon-Expandable Stent-Grafts for the Treatment of Infrarenal Penetrating Aortic Ulcers
title_short Multicenter Experience With Large Diameter Balloon-Expandable Stent-Grafts for the Treatment of Infrarenal Penetrating Aortic Ulcers
title_sort multicenter experience with large diameter balloon-expandable stent-grafts for the treatment of infrarenal penetrating aortic ulcers
topic Clinical Investigations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8573626/
https://www.ncbi.nlm.nih.gov/pubmed/34190634
http://dx.doi.org/10.1177/15266028211028221
work_keys_str_mv AT stanajan multicenterexperiencewithlargediameterballoonexpandablestentgraftsforthetreatmentofinfrarenalpenetratingaorticulcers
AT fernandezprendescarlota multicenterexperiencewithlargediameterballoonexpandablestentgraftsforthetreatmentofinfrarenalpenetratingaorticulcers
AT kruszynalukasz multicenterexperiencewithlargediameterballoonexpandablestentgraftsforthetreatmentofinfrarenalpenetratingaorticulcers
AT passaloglouioannisthomas multicenterexperiencewithlargediameterballoonexpandablestentgraftsforthetreatmentofinfrarenalpenetratingaorticulcers
AT ruffinomariaantonella multicenterexperiencewithlargediameterballoonexpandablestentgraftsforthetreatmentofinfrarenalpenetratingaorticulcers
AT reyesvaldiviaandres multicenterexperiencewithlargediameterballoonexpandablestentgraftsforthetreatmentofinfrarenalpenetratingaorticulcers
AT delcastromadrazojoseantonio multicenterexperiencewithlargediameterballoonexpandablestentgraftsforthetreatmentofinfrarenalpenetratingaorticulcers
AT oikonomoukyriakos multicenterexperiencewithlargediameterballoonexpandablestentgraftsforthetreatmentofinfrarenalpenetratingaorticulcers
AT chanhonlai multicenterexperiencewithlargediameterballoonexpandablestentgraftsforthetreatmentofinfrarenalpenetratingaorticulcers
AT makaloskivladimir multicenterexperiencewithlargediameterballoonexpandablestentgraftsforthetreatmentofinfrarenalpenetratingaorticulcers
AT tsilimparisnikolaos multicenterexperiencewithlargediameterballoonexpandablestentgraftsforthetreatmentofinfrarenalpenetratingaorticulcers