Cargando…

Fracture reduction has a dominant effect over cerclage wiring in increasing stiffness of intertrochanteric OTA/AO 31-A3.1 (reverse oblique) fractures managed with cephalomedullary osteosynthesis

OBJECTIVES: To investigate the mechanical properties of cephalomedullary nailing of intertrochanteric OTA/AO 31-A3.1 (reverse oblique) fractures and to test the hypothesis that anatomical reduction and augmentation with cerclage wire produces a more stable construct. METHODS: A standardized fracture...

Descripción completa

Detalles Bibliográficos
Autores principales: Hoskins, Wayne, Moniz, Sheldon, Day, Robert, Hayes, Alex, Bingham, Roger, Kuster, Markus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8575425/
https://www.ncbi.nlm.nih.gov/pubmed/34765902
http://dx.doi.org/10.1097/OI9.0000000000000152
_version_ 1784595675558707200
author Hoskins, Wayne
Moniz, Sheldon
Day, Robert
Hayes, Alex
Bingham, Roger
Kuster, Markus
author_facet Hoskins, Wayne
Moniz, Sheldon
Day, Robert
Hayes, Alex
Bingham, Roger
Kuster, Markus
author_sort Hoskins, Wayne
collection PubMed
description OBJECTIVES: To investigate the mechanical properties of cephalomedullary nailing of intertrochanteric OTA/AO 31-A3.1 (reverse oblique) fractures and to test the hypothesis that anatomical reduction and augmentation with cerclage wire produces a more stable construct. METHODS: A standardized fracture model in composite saw bone was created to stimulate an intertrochaneric 31-A3.1 fracture, using a 3D printed cutting guide. Simulated osteosynthesis was performed with 12 femurs divided into anatomically reduced and varus malreduced groups. Each femur was tested with and without cerclage wire augmentation. All femurs were fixed with a 215 mm, 130 degree, 11.5 mm nail. An Instron 8874 biaxial materials testing machine was used to assess the axial stiffness. Cyclic loading consisted of 5000 cycles of sinusoidal combined axial-torsion loading at 3 Hz. Axial load was 100 N to 2000 N and torsion −4.5 Nm to +4.5 Nm. Stiffness was measured before and after cyclic loading. RESULTS: Reduced constructs were stiffer than residual varus constructs. The mean overall fracture stiffness was 508.7 N/mm for reduced constructs and 379.2 N/mm for varus constructs. Removing the cables significantly decreased the fracture stiffness for both constructs (mean difference 60.0 N/mm, 95% CI 7.7–112.3, P = .032). CONCLUSIONS: Anatomical reduction has a dominant effect on facture stiffness. Anatomically reduced fractures are stiffer than varus malreduced fractures. A cerclage wire further improves construct stiffness if anatomical reduction is achieved. Cerclage wiring is less effective if anatomical reduction is not achieved.
format Online
Article
Text
id pubmed-8575425
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-85754252021-11-10 Fracture reduction has a dominant effect over cerclage wiring in increasing stiffness of intertrochanteric OTA/AO 31-A3.1 (reverse oblique) fractures managed with cephalomedullary osteosynthesis Hoskins, Wayne Moniz, Sheldon Day, Robert Hayes, Alex Bingham, Roger Kuster, Markus OTA Int Clinical/Basic Science Research Article OBJECTIVES: To investigate the mechanical properties of cephalomedullary nailing of intertrochanteric OTA/AO 31-A3.1 (reverse oblique) fractures and to test the hypothesis that anatomical reduction and augmentation with cerclage wire produces a more stable construct. METHODS: A standardized fracture model in composite saw bone was created to stimulate an intertrochaneric 31-A3.1 fracture, using a 3D printed cutting guide. Simulated osteosynthesis was performed with 12 femurs divided into anatomically reduced and varus malreduced groups. Each femur was tested with and without cerclage wire augmentation. All femurs were fixed with a 215 mm, 130 degree, 11.5 mm nail. An Instron 8874 biaxial materials testing machine was used to assess the axial stiffness. Cyclic loading consisted of 5000 cycles of sinusoidal combined axial-torsion loading at 3 Hz. Axial load was 100 N to 2000 N and torsion −4.5 Nm to +4.5 Nm. Stiffness was measured before and after cyclic loading. RESULTS: Reduced constructs were stiffer than residual varus constructs. The mean overall fracture stiffness was 508.7 N/mm for reduced constructs and 379.2 N/mm for varus constructs. Removing the cables significantly decreased the fracture stiffness for both constructs (mean difference 60.0 N/mm, 95% CI 7.7–112.3, P = .032). CONCLUSIONS: Anatomical reduction has a dominant effect on facture stiffness. Anatomically reduced fractures are stiffer than varus malreduced fractures. A cerclage wire further improves construct stiffness if anatomical reduction is achieved. Cerclage wiring is less effective if anatomical reduction is not achieved. Lippincott Williams & Wilkins 2021-09-15 /pmc/articles/PMC8575425/ /pubmed/34765902 http://dx.doi.org/10.1097/OI9.0000000000000152 Text en Copyright © 2021 The Authors. Published by Wolters Kluwer Health, Inc. on behalf of the Orthopaedic Trauma Association. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Clinical/Basic Science Research Article
Hoskins, Wayne
Moniz, Sheldon
Day, Robert
Hayes, Alex
Bingham, Roger
Kuster, Markus
Fracture reduction has a dominant effect over cerclage wiring in increasing stiffness of intertrochanteric OTA/AO 31-A3.1 (reverse oblique) fractures managed with cephalomedullary osteosynthesis
title Fracture reduction has a dominant effect over cerclage wiring in increasing stiffness of intertrochanteric OTA/AO 31-A3.1 (reverse oblique) fractures managed with cephalomedullary osteosynthesis
title_full Fracture reduction has a dominant effect over cerclage wiring in increasing stiffness of intertrochanteric OTA/AO 31-A3.1 (reverse oblique) fractures managed with cephalomedullary osteosynthesis
title_fullStr Fracture reduction has a dominant effect over cerclage wiring in increasing stiffness of intertrochanteric OTA/AO 31-A3.1 (reverse oblique) fractures managed with cephalomedullary osteosynthesis
title_full_unstemmed Fracture reduction has a dominant effect over cerclage wiring in increasing stiffness of intertrochanteric OTA/AO 31-A3.1 (reverse oblique) fractures managed with cephalomedullary osteosynthesis
title_short Fracture reduction has a dominant effect over cerclage wiring in increasing stiffness of intertrochanteric OTA/AO 31-A3.1 (reverse oblique) fractures managed with cephalomedullary osteosynthesis
title_sort fracture reduction has a dominant effect over cerclage wiring in increasing stiffness of intertrochanteric ota/ao 31-a3.1 (reverse oblique) fractures managed with cephalomedullary osteosynthesis
topic Clinical/Basic Science Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8575425/
https://www.ncbi.nlm.nih.gov/pubmed/34765902
http://dx.doi.org/10.1097/OI9.0000000000000152
work_keys_str_mv AT hoskinswayne fracturereductionhasadominanteffectovercerclagewiringinincreasingstiffnessofintertrochantericotaao31a31reverseobliquefracturesmanagedwithcephalomedullaryosteosynthesis
AT monizsheldon fracturereductionhasadominanteffectovercerclagewiringinincreasingstiffnessofintertrochantericotaao31a31reverseobliquefracturesmanagedwithcephalomedullaryosteosynthesis
AT dayrobert fracturereductionhasadominanteffectovercerclagewiringinincreasingstiffnessofintertrochantericotaao31a31reverseobliquefracturesmanagedwithcephalomedullaryosteosynthesis
AT hayesalex fracturereductionhasadominanteffectovercerclagewiringinincreasingstiffnessofintertrochantericotaao31a31reverseobliquefracturesmanagedwithcephalomedullaryosteosynthesis
AT binghamroger fracturereductionhasadominanteffectovercerclagewiringinincreasingstiffnessofintertrochantericotaao31a31reverseobliquefracturesmanagedwithcephalomedullaryosteosynthesis
AT kustermarkus fracturereductionhasadominanteffectovercerclagewiringinincreasingstiffnessofintertrochantericotaao31a31reverseobliquefracturesmanagedwithcephalomedullaryosteosynthesis