Investigation of the effect of a 15-degree tilt-in-space on the fluctuation of shear forces exerted on the buttocks when the back support is reclined
[Purpose] This study aimed to investigate the effect of the combination of 15° tilt-in-space and recline angles on the fluctuation of shear forces exerted on the buttocks. [Participants and Methods] The participants were 11 healthy adult males. The parameters of the shear forces were the parallel an...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Society of Physical Therapy Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8575471/ https://www.ncbi.nlm.nih.gov/pubmed/34776619 http://dx.doi.org/10.1589/jpts.33.838 |
Sumario: | [Purpose] This study aimed to investigate the effect of the combination of 15° tilt-in-space and recline angles on the fluctuation of shear forces exerted on the buttocks. [Participants and Methods] The participants were 11 healthy adult males. The parameters of the shear forces were the parallel and perpendicular forces exerted on the buttocks as measured by a force plate. The two conditions tested were T0R100-130 and T15R100-130. The tilt-in-space angles were set to 0° and 15° in the T0R100-130 and T15R100-130 conditions, respectively. The reclining angles were determined to be 100° to 130° in both conditions. [Results] Upon comparing the two conditions, the parallel and the perpendicular forces exerted on the buttocks in the T15R100-130 condition were significantly lower than those in the T0R100-130 condition in all positions of back support. Upon comparing the fluctuation values of the parallel and perpendicular forces, those applied in the T15R100-130 condition were significantly higher than those in the T0R100-130 condition. [Conclusion] These results suggest that the fluctuation of shear forces exerted on the buttocks could be decreased by using a combination of 15° tilt-in-space and reclining functions. |
---|