Cargando…
Inter-rater reliability of a wright respirometer to measure vital capacity in neuromuscular disorders
[Purpose] We examined the inter-rater reliability of the Wright respirometer between therapists who assessed the vital capacity of patients with neuromuscular disorders. [Participants and Methods] We examined 18 patients with neuromuscular disorders. We performed a test-retest method after measuring...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Society of Physical Therapy Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8575478/ https://www.ncbi.nlm.nih.gov/pubmed/34776615 http://dx.doi.org/10.1589/jpts.33.818 |
_version_ | 1784595687344701440 |
---|---|
author | Yoshinaga, Ryuji Futsuhara, Haruki |
author_facet | Yoshinaga, Ryuji Futsuhara, Haruki |
author_sort | Yoshinaga, Ryuji |
collection | PubMed |
description | [Purpose] We examined the inter-rater reliability of the Wright respirometer between therapists who assessed the vital capacity of patients with neuromuscular disorders. [Participants and Methods] We examined 18 patients with neuromuscular disorders. We performed a test-retest method after measuring their vital capacities. Two physical therapists experienced in the use of the Wright respirometer, specifically, therapist A with six years of clinical experience and therapist B with one, each took one measurement of the vital capacity of the same patients. The measurements between the therapists were taken at intervals of 3–7 days. We made a manual to standardize the measurements between the therapists. [Results] The vital capacities were 905 ± 490 mL for therapist A and 897 ± 483 mL for therapist B. The inter-rater reliability of ICC(2,1) was 0.96 (95% CI: 0.89–0.98). Bland-Altman analyses revealed neither a fixed nor proportional bias. [Conclusion] These results demonstrated good to excellent inter-rater reliability of the Wright respirometer for patients with neuromuscular disorders using a manual and instructions. |
format | Online Article Text |
id | pubmed-8575478 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Society of Physical Therapy Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-85754782021-11-13 Inter-rater reliability of a wright respirometer to measure vital capacity in neuromuscular disorders Yoshinaga, Ryuji Futsuhara, Haruki J Phys Ther Sci Original Article [Purpose] We examined the inter-rater reliability of the Wright respirometer between therapists who assessed the vital capacity of patients with neuromuscular disorders. [Participants and Methods] We examined 18 patients with neuromuscular disorders. We performed a test-retest method after measuring their vital capacities. Two physical therapists experienced in the use of the Wright respirometer, specifically, therapist A with six years of clinical experience and therapist B with one, each took one measurement of the vital capacity of the same patients. The measurements between the therapists were taken at intervals of 3–7 days. We made a manual to standardize the measurements between the therapists. [Results] The vital capacities were 905 ± 490 mL for therapist A and 897 ± 483 mL for therapist B. The inter-rater reliability of ICC(2,1) was 0.96 (95% CI: 0.89–0.98). Bland-Altman analyses revealed neither a fixed nor proportional bias. [Conclusion] These results demonstrated good to excellent inter-rater reliability of the Wright respirometer for patients with neuromuscular disorders using a manual and instructions. The Society of Physical Therapy Science 2021-11-09 2021-11 /pmc/articles/PMC8575478/ /pubmed/34776615 http://dx.doi.org/10.1589/jpts.33.818 Text en 2021©by the Society of Physical Therapy Science. Published by IPEC Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License. (CC-BY-NC-ND 4.0: https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Original Article Yoshinaga, Ryuji Futsuhara, Haruki Inter-rater reliability of a wright respirometer to measure vital capacity in neuromuscular disorders |
title | Inter-rater reliability of a wright respirometer to measure vital capacity in neuromuscular disorders |
title_full | Inter-rater reliability of a wright respirometer to measure vital capacity in neuromuscular disorders |
title_fullStr | Inter-rater reliability of a wright respirometer to measure vital capacity in neuromuscular disorders |
title_full_unstemmed | Inter-rater reliability of a wright respirometer to measure vital capacity in neuromuscular disorders |
title_short | Inter-rater reliability of a wright respirometer to measure vital capacity in neuromuscular disorders |
title_sort | inter-rater reliability of a wright respirometer to measure vital capacity in neuromuscular disorders |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8575478/ https://www.ncbi.nlm.nih.gov/pubmed/34776615 http://dx.doi.org/10.1589/jpts.33.818 |
work_keys_str_mv | AT yoshinagaryuji interraterreliabilityofawrightrespirometertomeasurevitalcapacityinneuromusculardisorders AT futsuharaharuki interraterreliabilityofawrightrespirometertomeasurevitalcapacityinneuromusculardisorders |