Comparison of Rhenium and Iodine as Contrast Agents in X-Ray Imaging
PURPOSE: The majority of X-ray contrast agents (XCA) are made with iodine, but iodine-based XCA (I-XCA) exhibit low contrast in high kVp X-rays due to iodine's low atomic number (Z = 53) and K-edge (33.1 keV). While rhenium is a transition metal with a high atomic number (Z = 75) and K-edge (71...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8575601/ https://www.ncbi.nlm.nih.gov/pubmed/34803544 http://dx.doi.org/10.1155/2021/1250360 |
_version_ | 1784595708025765888 |
---|---|
author | De La Vega, José Carlos Esquinas, Pedro Luis Gill, Jovan Kaur Jessa, Selin Gill, Bradford Thakur, Yogesh Saatchi, Katayoun Häfeli, Urs O. |
author_facet | De La Vega, José Carlos Esquinas, Pedro Luis Gill, Jovan Kaur Jessa, Selin Gill, Bradford Thakur, Yogesh Saatchi, Katayoun Häfeli, Urs O. |
author_sort | De La Vega, José Carlos |
collection | PubMed |
description | PURPOSE: The majority of X-ray contrast agents (XCA) are made with iodine, but iodine-based XCA (I-XCA) exhibit low contrast in high kVp X-rays due to iodine's low atomic number (Z = 53) and K-edge (33.1 keV). While rhenium is a transition metal with a high atomic number (Z = 75) and K-edge (71.7 keV), the utilization of rhenium-based XCA (Re-XCA) in X-ray imaging techniques has not been studied in depth. Our study had two objectives: (1) to compare both the image quality and the absorbed dose of I- and Re-XCA and (2) to prepare and image a rhenium-doped scaffold. Procedures. I- and Re-XCA were prepared and imaged from 50 to 120 kVp by Micro-computed tomography (µCT) and digital radiography and from 120 to 220 kVp by planar X-ray imaging. The scans were repeated using 0.1 to 1.6 mm thick copper filters to harden the X-ray beam. A rhenium-doped scaffold was prepared via electrospinning, used to coat catheters, and imaged at 90 kVp by µCT. RESULTS: I-XCA have a greater contrast-to-noise ratio (CNR) at 50 and 80 kVp, but Re-XCA have a greater CNR at >120 kVp. The difference in CNR is increased as the thickness of the copper filters is increased. For instance, the percent CNR improvement of rhenium over iodine is 14.2% with a 0.6 mm thick copper filter, but it is 59.1% with a 1.6 mm thick copper filter, as shown at 120 kVp by µCT. Upon coating them with a rhenium-doped scaffold, the catheters became radiopaque. CONCLUSIONS: Using Monte Carlo simulations, we showed that it is possible to reduce the absorbed dose of high kVp X-rays while allowing the acquisition of high-quality images. Furthermore, radiopaque catheters have the potential of enhancing the contrast during catheterizations and helping physicians to place catheters inside patients more rapidly and precisely. |
format | Online Article Text |
id | pubmed-8575601 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-85756012021-11-18 Comparison of Rhenium and Iodine as Contrast Agents in X-Ray Imaging De La Vega, José Carlos Esquinas, Pedro Luis Gill, Jovan Kaur Jessa, Selin Gill, Bradford Thakur, Yogesh Saatchi, Katayoun Häfeli, Urs O. Contrast Media Mol Imaging Research Article PURPOSE: The majority of X-ray contrast agents (XCA) are made with iodine, but iodine-based XCA (I-XCA) exhibit low contrast in high kVp X-rays due to iodine's low atomic number (Z = 53) and K-edge (33.1 keV). While rhenium is a transition metal with a high atomic number (Z = 75) and K-edge (71.7 keV), the utilization of rhenium-based XCA (Re-XCA) in X-ray imaging techniques has not been studied in depth. Our study had two objectives: (1) to compare both the image quality and the absorbed dose of I- and Re-XCA and (2) to prepare and image a rhenium-doped scaffold. Procedures. I- and Re-XCA were prepared and imaged from 50 to 120 kVp by Micro-computed tomography (µCT) and digital radiography and from 120 to 220 kVp by planar X-ray imaging. The scans were repeated using 0.1 to 1.6 mm thick copper filters to harden the X-ray beam. A rhenium-doped scaffold was prepared via electrospinning, used to coat catheters, and imaged at 90 kVp by µCT. RESULTS: I-XCA have a greater contrast-to-noise ratio (CNR) at 50 and 80 kVp, but Re-XCA have a greater CNR at >120 kVp. The difference in CNR is increased as the thickness of the copper filters is increased. For instance, the percent CNR improvement of rhenium over iodine is 14.2% with a 0.6 mm thick copper filter, but it is 59.1% with a 1.6 mm thick copper filter, as shown at 120 kVp by µCT. Upon coating them with a rhenium-doped scaffold, the catheters became radiopaque. CONCLUSIONS: Using Monte Carlo simulations, we showed that it is possible to reduce the absorbed dose of high kVp X-rays while allowing the acquisition of high-quality images. Furthermore, radiopaque catheters have the potential of enhancing the contrast during catheterizations and helping physicians to place catheters inside patients more rapidly and precisely. Hindawi 2021-11-01 /pmc/articles/PMC8575601/ /pubmed/34803544 http://dx.doi.org/10.1155/2021/1250360 Text en Copyright © 2021 José Carlos De La Vega et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article De La Vega, José Carlos Esquinas, Pedro Luis Gill, Jovan Kaur Jessa, Selin Gill, Bradford Thakur, Yogesh Saatchi, Katayoun Häfeli, Urs O. Comparison of Rhenium and Iodine as Contrast Agents in X-Ray Imaging |
title | Comparison of Rhenium and Iodine as Contrast Agents in X-Ray Imaging |
title_full | Comparison of Rhenium and Iodine as Contrast Agents in X-Ray Imaging |
title_fullStr | Comparison of Rhenium and Iodine as Contrast Agents in X-Ray Imaging |
title_full_unstemmed | Comparison of Rhenium and Iodine as Contrast Agents in X-Ray Imaging |
title_short | Comparison of Rhenium and Iodine as Contrast Agents in X-Ray Imaging |
title_sort | comparison of rhenium and iodine as contrast agents in x-ray imaging |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8575601/ https://www.ncbi.nlm.nih.gov/pubmed/34803544 http://dx.doi.org/10.1155/2021/1250360 |
work_keys_str_mv | AT delavegajosecarlos comparisonofrheniumandiodineascontrastagentsinxrayimaging AT esquinaspedroluis comparisonofrheniumandiodineascontrastagentsinxrayimaging AT gilljovankaur comparisonofrheniumandiodineascontrastagentsinxrayimaging AT jessaselin comparisonofrheniumandiodineascontrastagentsinxrayimaging AT gillbradford comparisonofrheniumandiodineascontrastagentsinxrayimaging AT thakuryogesh comparisonofrheniumandiodineascontrastagentsinxrayimaging AT saatchikatayoun comparisonofrheniumandiodineascontrastagentsinxrayimaging AT hafeliurso comparisonofrheniumandiodineascontrastagentsinxrayimaging |