Cargando…

Outcome after Two Sequential Revision Hip Arthroplasties for CoC Bearing Fracture with 10 Years Follow-up: A Case Report

INTRODUCTION: Revisions due to the fracture of ceramic-on-ceramic (CoC) bearing are rare, however when they occur, they represent a major challenge to an orthopedic surgeon for ensuring safe and long-term survival of the replaced bearing. CASE REPORT: We present a case of fractured ceramic liner of...

Descripción completa

Detalles Bibliográficos
Autores principales: Topolovec, Matevž, Milošev, Ingrid, Cör, Andrej
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Indian Orthopaedic Research Group 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8576786/
https://www.ncbi.nlm.nih.gov/pubmed/34790602
http://dx.doi.org/10.13107/jocr.2021.v11.i07.2310
_version_ 1784595949514915840
author Topolovec, Matevž
Milošev, Ingrid
Cör, Andrej
author_facet Topolovec, Matevž
Milošev, Ingrid
Cör, Andrej
author_sort Topolovec, Matevž
collection PubMed
description INTRODUCTION: Revisions due to the fracture of ceramic-on-ceramic (CoC) bearing are rare, however when they occur, they represent a major challenge to an orthopedic surgeon for ensuring safe and long-term survival of the replaced bearing. CASE REPORT: We present a case of fractured ceramic liner of total hip prosthesis that underwent revision to a metal-on-polyethylene (MoP) bearing couple, with consequent huge periprosthetic metallosis. Shortly after, the second revision operation followed using the third bearing couple of ceramic-on-polyethylene (CoP). At 10 years follow-up after the operation due to ceramic fracture, the patient is now pain free with full range of motion of the revised hip. CONCLUSION: Establishment of diagnostic routes and recommended protocols for CoC bearing fracture would allow easier recognition of potential fracture and diminish its consequences for the patients.
format Online
Article
Text
id pubmed-8576786
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Indian Orthopaedic Research Group
record_format MEDLINE/PubMed
spelling pubmed-85767862021-11-16 Outcome after Two Sequential Revision Hip Arthroplasties for CoC Bearing Fracture with 10 Years Follow-up: A Case Report Topolovec, Matevž Milošev, Ingrid Cör, Andrej J Orthop Case Rep Case Report INTRODUCTION: Revisions due to the fracture of ceramic-on-ceramic (CoC) bearing are rare, however when they occur, they represent a major challenge to an orthopedic surgeon for ensuring safe and long-term survival of the replaced bearing. CASE REPORT: We present a case of fractured ceramic liner of total hip prosthesis that underwent revision to a metal-on-polyethylene (MoP) bearing couple, with consequent huge periprosthetic metallosis. Shortly after, the second revision operation followed using the third bearing couple of ceramic-on-polyethylene (CoP). At 10 years follow-up after the operation due to ceramic fracture, the patient is now pain free with full range of motion of the revised hip. CONCLUSION: Establishment of diagnostic routes and recommended protocols for CoC bearing fracture would allow easier recognition of potential fracture and diminish its consequences for the patients. Indian Orthopaedic Research Group 2021-07 2021-07 /pmc/articles/PMC8576786/ /pubmed/34790602 http://dx.doi.org/10.13107/jocr.2021.v11.i07.2310 Text en Copyright: © Indian Orthopaedic Research Group https://creativecommons.org/licenses/by-nc-sa/3.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Topolovec, Matevž
Milošev, Ingrid
Cör, Andrej
Outcome after Two Sequential Revision Hip Arthroplasties for CoC Bearing Fracture with 10 Years Follow-up: A Case Report
title Outcome after Two Sequential Revision Hip Arthroplasties for CoC Bearing Fracture with 10 Years Follow-up: A Case Report
title_full Outcome after Two Sequential Revision Hip Arthroplasties for CoC Bearing Fracture with 10 Years Follow-up: A Case Report
title_fullStr Outcome after Two Sequential Revision Hip Arthroplasties for CoC Bearing Fracture with 10 Years Follow-up: A Case Report
title_full_unstemmed Outcome after Two Sequential Revision Hip Arthroplasties for CoC Bearing Fracture with 10 Years Follow-up: A Case Report
title_short Outcome after Two Sequential Revision Hip Arthroplasties for CoC Bearing Fracture with 10 Years Follow-up: A Case Report
title_sort outcome after two sequential revision hip arthroplasties for coc bearing fracture with 10 years follow-up: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8576786/
https://www.ncbi.nlm.nih.gov/pubmed/34790602
http://dx.doi.org/10.13107/jocr.2021.v11.i07.2310
work_keys_str_mv AT topolovecmatevz outcomeaftertwosequentialrevisionhiparthroplastiesforcocbearingfracturewith10yearsfollowupacasereport
AT milosevingrid outcomeaftertwosequentialrevisionhiparthroplastiesforcocbearingfracturewith10yearsfollowupacasereport
AT corandrej outcomeaftertwosequentialrevisionhiparthroplastiesforcocbearingfracturewith10yearsfollowupacasereport