Cargando…
Improved durable pulmonary vein isolation with shorter procedure times and lower energy levels using RF ablation with ablation index and a stringent lesion contiguity
BACKGROUND: The single procedure success rates of durable pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) varies between 80 and 90%. Ablation index, incorporating contact force, stability, time and power is a more profound parameter of significant lesion size and has been est...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8577154/ https://www.ncbi.nlm.nih.gov/pubmed/34438060 http://dx.doi.org/10.1016/j.ipej.2021.08.005 |
_version_ | 1784596021313011712 |
---|---|
author | Theis, Cathrin Huber, Carola Kaiser, Bastian Kaesemann, Philipp Hui, Felix Pirozzolo, Giancarlo Bekeredjian, Raffi |
author_facet | Theis, Cathrin Huber, Carola Kaiser, Bastian Kaesemann, Philipp Hui, Felix Pirozzolo, Giancarlo Bekeredjian, Raffi |
author_sort | Theis, Cathrin |
collection | PubMed |
description | BACKGROUND: The single procedure success rates of durable pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) varies between 80 and 90%. Ablation index, incorporating contact force, stability, time and power is a more profound parameter of significant lesion size and has been established. Equally important is a stringent contiguity of the lesion set. METHODS AND RESULTS: A total number of 100 consecutive patients undergoing de-novo catheter ablation for paroxysmal atrial fibrillation (PAF) were analyzed between 2016 and 2019. In the first 50 patients (group A) PVI was performed using a surround flow, contact force catheter (Biosense Webster Thermocool STSF, Biosense Webster, USA) with a drag-and-ablate technique to encircle the PVs. In the following 50 patients (group B), PVI was performed using ablation index and a stringent lesion contiguity with an interlesion distance (ILD) of <5 mm. The baseline characteristics showed no significant differences between both groups. During a mean follow-up of 18 ± 3 months after a single procedure, 36 (72%) patients of group A were free of arrhythmia recurrence versus 43 (86%) patients in group B (p = 0.047). A total of 14 patients (group A: 10 (20%), group B: 4 (8%); underwent a redo-procedure. 7 patients of group A (14%) and 2 patients of group B (4%) showed recovered veins. In 3 patients of group A and 2 patients of group B the PVs were durably isolated. In these patients persistent AF recurrence was caused by extra-PV AF sources. Four patients of group A and three patients of group B had continued paroxysmal or persistent AF but did not undergo redo-procedure. With regard to the procedural data, the procedure time, the total energy and the fluoroscopy time were significantly lower in group B (AI and ILD <5 mm) (128.86 ± 18.19 versus 115.35 ± 15.38; p < 0.05; 1619.16 ± 988.56 versus 1186.26 ± 756.34; p < 0.05; 11.49 ± 3.20 versus 9.66 ± 3.86; p = 0.04). Both procedures were performed with a low number of complications, no pericardial effusion was seen in either group. CONCLUSIONS: PVI using ablation index in combination with a stringent lesion contiguity improves clinical outcome after first-time PVI with lower PVI recovery, shorter procedure times, lower total energy and shorter fluoroscopy times and therefore, is more efficient. |
format | Online Article Text |
id | pubmed-8577154 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-85771542021-11-12 Improved durable pulmonary vein isolation with shorter procedure times and lower energy levels using RF ablation with ablation index and a stringent lesion contiguity Theis, Cathrin Huber, Carola Kaiser, Bastian Kaesemann, Philipp Hui, Felix Pirozzolo, Giancarlo Bekeredjian, Raffi Indian Pacing Electrophysiol J Original Article BACKGROUND: The single procedure success rates of durable pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) varies between 80 and 90%. Ablation index, incorporating contact force, stability, time and power is a more profound parameter of significant lesion size and has been established. Equally important is a stringent contiguity of the lesion set. METHODS AND RESULTS: A total number of 100 consecutive patients undergoing de-novo catheter ablation for paroxysmal atrial fibrillation (PAF) were analyzed between 2016 and 2019. In the first 50 patients (group A) PVI was performed using a surround flow, contact force catheter (Biosense Webster Thermocool STSF, Biosense Webster, USA) with a drag-and-ablate technique to encircle the PVs. In the following 50 patients (group B), PVI was performed using ablation index and a stringent lesion contiguity with an interlesion distance (ILD) of <5 mm. The baseline characteristics showed no significant differences between both groups. During a mean follow-up of 18 ± 3 months after a single procedure, 36 (72%) patients of group A were free of arrhythmia recurrence versus 43 (86%) patients in group B (p = 0.047). A total of 14 patients (group A: 10 (20%), group B: 4 (8%); underwent a redo-procedure. 7 patients of group A (14%) and 2 patients of group B (4%) showed recovered veins. In 3 patients of group A and 2 patients of group B the PVs were durably isolated. In these patients persistent AF recurrence was caused by extra-PV AF sources. Four patients of group A and three patients of group B had continued paroxysmal or persistent AF but did not undergo redo-procedure. With regard to the procedural data, the procedure time, the total energy and the fluoroscopy time were significantly lower in group B (AI and ILD <5 mm) (128.86 ± 18.19 versus 115.35 ± 15.38; p < 0.05; 1619.16 ± 988.56 versus 1186.26 ± 756.34; p < 0.05; 11.49 ± 3.20 versus 9.66 ± 3.86; p = 0.04). Both procedures were performed with a low number of complications, no pericardial effusion was seen in either group. CONCLUSIONS: PVI using ablation index in combination with a stringent lesion contiguity improves clinical outcome after first-time PVI with lower PVI recovery, shorter procedure times, lower total energy and shorter fluoroscopy times and therefore, is more efficient. Elsevier 2021-08-23 /pmc/articles/PMC8577154/ /pubmed/34438060 http://dx.doi.org/10.1016/j.ipej.2021.08.005 Text en © 2021 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Theis, Cathrin Huber, Carola Kaiser, Bastian Kaesemann, Philipp Hui, Felix Pirozzolo, Giancarlo Bekeredjian, Raffi Improved durable pulmonary vein isolation with shorter procedure times and lower energy levels using RF ablation with ablation index and a stringent lesion contiguity |
title | Improved durable pulmonary vein isolation with shorter procedure times and lower energy levels using RF ablation with ablation index and a stringent lesion contiguity |
title_full | Improved durable pulmonary vein isolation with shorter procedure times and lower energy levels using RF ablation with ablation index and a stringent lesion contiguity |
title_fullStr | Improved durable pulmonary vein isolation with shorter procedure times and lower energy levels using RF ablation with ablation index and a stringent lesion contiguity |
title_full_unstemmed | Improved durable pulmonary vein isolation with shorter procedure times and lower energy levels using RF ablation with ablation index and a stringent lesion contiguity |
title_short | Improved durable pulmonary vein isolation with shorter procedure times and lower energy levels using RF ablation with ablation index and a stringent lesion contiguity |
title_sort | improved durable pulmonary vein isolation with shorter procedure times and lower energy levels using rf ablation with ablation index and a stringent lesion contiguity |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8577154/ https://www.ncbi.nlm.nih.gov/pubmed/34438060 http://dx.doi.org/10.1016/j.ipej.2021.08.005 |
work_keys_str_mv | AT theiscathrin improveddurablepulmonaryveinisolationwithshorterproceduretimesandlowerenergylevelsusingrfablationwithablationindexandastringentlesioncontiguity AT hubercarola improveddurablepulmonaryveinisolationwithshorterproceduretimesandlowerenergylevelsusingrfablationwithablationindexandastringentlesioncontiguity AT kaiserbastian improveddurablepulmonaryveinisolationwithshorterproceduretimesandlowerenergylevelsusingrfablationwithablationindexandastringentlesioncontiguity AT kaesemannphilipp improveddurablepulmonaryveinisolationwithshorterproceduretimesandlowerenergylevelsusingrfablationwithablationindexandastringentlesioncontiguity AT huifelix improveddurablepulmonaryveinisolationwithshorterproceduretimesandlowerenergylevelsusingrfablationwithablationindexandastringentlesioncontiguity AT pirozzologiancarlo improveddurablepulmonaryveinisolationwithshorterproceduretimesandlowerenergylevelsusingrfablationwithablationindexandastringentlesioncontiguity AT bekeredjianraffi improveddurablepulmonaryveinisolationwithshorterproceduretimesandlowerenergylevelsusingrfablationwithablationindexandastringentlesioncontiguity |