Hand-Arm Vibration Exposure in Rock Drill Workers: A Comparison between Measurements with Hand-Attached and Tool-Attached Accelerometers

OBJECTIVES: To assess the hazard of tool vibrations, we need valid exposure measurements. The use of hand-attached accelerometers (vibration sensors) to measure hand-arm vibrations (HAVs) has become a popular approach. However, according to International Standard ISO 5349-2, the preferred attachment...

Descripción completa

Detalles Bibliográficos
Autores principales: Clemm, Thomas, Nordby, Karl-Christian, Lunde, Lars-Kristian, Ulvestad, Bente, Bråtveit, Magne
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8577229/
https://www.ncbi.nlm.nih.gov/pubmed/34254993
http://dx.doi.org/10.1093/annweh/wxab051
Descripción
Sumario:OBJECTIVES: To assess the hazard of tool vibrations, we need valid exposure measurements. The use of hand-attached accelerometers (vibration sensors) to measure hand-arm vibrations (HAVs) has become a popular approach. However, according to International Standard ISO 5349-2, the preferred attachment of accelerometers is at the tool handle. We compared measures of HAV between hand- and tool-attached accelerometers in rock drilling. METHODS: We measured HAV in five rock drillers using jackleg drills in normal working operations with simultaneous measures of both hand-attached and tool-attached accelerometers. Five to seven measurement cycles of 15 s were executed on each worker, resulting in a total of 29 measurement cycles. To identify possible differences in working technique, we recorded videos of tool handle handgrips during drilling. RESULTS: There was a significant difference (9.5 m s(−2); P ≤ 0.05) in vibration magnitudes measured by the tool-attached accelerometers compared with the hand-attached accelerometers. The hand-attached accelerometer showed a lower vibration magnitude for all workers (range of difference: 2.3–14.6). The variation between the two accelerometer attachments was larger between workers than within workers (ICC = 0.68). CONCLUSIONS: For measurements of HAV from jackleg drills, the use of hand-attached accelerometers may cause a lower recorded vibration level compared with tool-attached accelerometers. This difference is likely to vary depending on how workers grip the tool handle, and a misclassification of exposure will occur if workers grip the tool handle in a way that makes the accelerometer lose contact with the vibrating surface. Individual differences in how workers grip the tool handles should be considered when assessing HAV.