Cargando…
Osseointegration Aspects of Implants at the Bone Reconstruction Site by a Novel Porous Titanium Scaffold
OBJECTIVES: Porous titanium is used for the reconstruction of large bone defects due to its excellent mechanical strength. The quality of osseointegration of implants placed in bone reconstructed with porous titanium is unknown. The purpose of this in vivo study was to evaluate the osseointegration...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Stilus Optimus
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8577583/ https://www.ncbi.nlm.nih.gov/pubmed/34777726 http://dx.doi.org/10.5037/jomr.2021.12304 |
_version_ | 1784596089142247424 |
---|---|
author | Doi, Kazuya Kobatake, Reiko Makihara, Yusuke Oki, Yoshifumi Umehara, Hanako Kubo, Takayasu Tsuga, Kazuhiro |
author_facet | Doi, Kazuya Kobatake, Reiko Makihara, Yusuke Oki, Yoshifumi Umehara, Hanako Kubo, Takayasu Tsuga, Kazuhiro |
author_sort | Doi, Kazuya |
collection | PubMed |
description | OBJECTIVES: Porous titanium is used for the reconstruction of large bone defects due to its excellent mechanical strength. The quality of osseointegration of implants placed in bone reconstructed with porous titanium is unknown. The purpose of this in vivo study was to evaluate the osseointegration of implants at sites reconstructed using porous titanium. MATERIAL AND METHODS: Hollow porous titanium (Ti) (outer-diameter 6 mm, inner-diameter 2 mm, length 4 mm, 85% porosity) and similar-sized porous hydroxyapatite (porous HA: 75% porosity) samples were prepared and implanted in 6 New Zealand white rabbit femurs. Four weeks later, an implant bed was created to receive a Ti implant (diameter 2 mm, length 4 mm). An implant placed at a pristine bone site served as the control. Four weeks later, histological and histomorphometric evaluations of the test and control sites were conducted. RESULTS: Osseointegration was observed in all groups. There was no significant difference in the bone formation ratio and bone-implant contact (BIC) ratio across all groups for the whole area. At the cancellous bone area of the bone defect, superior bone formation ratio and BIC ratio were observed with porous Ti and porous HA compared to the control (bone formation ratio: control 1.8 [SD 3]%, HA 23 [SD 3]%, Ti 23.6 [SD 5]%; BIC ratio: control 5.4 [SD 5.3]%, HA 28.9 [SD 10.7]%, Ti 41.6 [SD 14]%). Porous Ti demonstrated good osteoconduction and osseointegration abilities, similar to porous HA. CONCLUSIONS: To our knowledge, this is the first report of implant treatment after preliminary bone reconstruction using a titanium biomaterial. Porous titanium is a suitable material for bone reconstruction before implant treatment in load-bearing areas that allow subsequent prosthetic treatment. |
format | Online Article Text |
id | pubmed-8577583 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Stilus Optimus |
record_format | MEDLINE/PubMed |
spelling | pubmed-85775832021-11-12 Osseointegration Aspects of Implants at the Bone Reconstruction Site by a Novel Porous Titanium Scaffold Doi, Kazuya Kobatake, Reiko Makihara, Yusuke Oki, Yoshifumi Umehara, Hanako Kubo, Takayasu Tsuga, Kazuhiro J Oral Maxillofac Res Original Paper OBJECTIVES: Porous titanium is used for the reconstruction of large bone defects due to its excellent mechanical strength. The quality of osseointegration of implants placed in bone reconstructed with porous titanium is unknown. The purpose of this in vivo study was to evaluate the osseointegration of implants at sites reconstructed using porous titanium. MATERIAL AND METHODS: Hollow porous titanium (Ti) (outer-diameter 6 mm, inner-diameter 2 mm, length 4 mm, 85% porosity) and similar-sized porous hydroxyapatite (porous HA: 75% porosity) samples were prepared and implanted in 6 New Zealand white rabbit femurs. Four weeks later, an implant bed was created to receive a Ti implant (diameter 2 mm, length 4 mm). An implant placed at a pristine bone site served as the control. Four weeks later, histological and histomorphometric evaluations of the test and control sites were conducted. RESULTS: Osseointegration was observed in all groups. There was no significant difference in the bone formation ratio and bone-implant contact (BIC) ratio across all groups for the whole area. At the cancellous bone area of the bone defect, superior bone formation ratio and BIC ratio were observed with porous Ti and porous HA compared to the control (bone formation ratio: control 1.8 [SD 3]%, HA 23 [SD 3]%, Ti 23.6 [SD 5]%; BIC ratio: control 5.4 [SD 5.3]%, HA 28.9 [SD 10.7]%, Ti 41.6 [SD 14]%). Porous Ti demonstrated good osteoconduction and osseointegration abilities, similar to porous HA. CONCLUSIONS: To our knowledge, this is the first report of implant treatment after preliminary bone reconstruction using a titanium biomaterial. Porous titanium is a suitable material for bone reconstruction before implant treatment in load-bearing areas that allow subsequent prosthetic treatment. Stilus Optimus 2021-09-30 /pmc/articles/PMC8577583/ /pubmed/34777726 http://dx.doi.org/10.5037/jomr.2021.12304 Text en Copyright © Doi K, Kobatake R, Makihara Y, Oki Y, Umehara H, Kubo T, Tsuga K. Published in the JOURNAL OF ORAL & MAXILLOFACIAL RESEARCH (http://www.ejomr.org), 30 September 2021. https://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article, first published in the JOURNAL OF ORAL & MAXILLOFACIAL RESEARCH, distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 UnportedLicense (http://creativecommons.org/licenses/by-nc-nd/3.0/ (https://creativecommons.org/licenses/by-nc-nd/3.0/) ), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work and is properly cited. The copyright, license information and link to the original publication on (http://www.ejomr.org) must be included. |
spellingShingle | Original Paper Doi, Kazuya Kobatake, Reiko Makihara, Yusuke Oki, Yoshifumi Umehara, Hanako Kubo, Takayasu Tsuga, Kazuhiro Osseointegration Aspects of Implants at the Bone Reconstruction Site by a Novel Porous Titanium Scaffold |
title | Osseointegration Aspects of Implants at the Bone Reconstruction Site by a Novel Porous Titanium Scaffold |
title_full | Osseointegration Aspects of Implants at the Bone Reconstruction Site by a Novel Porous Titanium Scaffold |
title_fullStr | Osseointegration Aspects of Implants at the Bone Reconstruction Site by a Novel Porous Titanium Scaffold |
title_full_unstemmed | Osseointegration Aspects of Implants at the Bone Reconstruction Site by a Novel Porous Titanium Scaffold |
title_short | Osseointegration Aspects of Implants at the Bone Reconstruction Site by a Novel Porous Titanium Scaffold |
title_sort | osseointegration aspects of implants at the bone reconstruction site by a novel porous titanium scaffold |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8577583/ https://www.ncbi.nlm.nih.gov/pubmed/34777726 http://dx.doi.org/10.5037/jomr.2021.12304 |
work_keys_str_mv | AT doikazuya osseointegrationaspectsofimplantsatthebonereconstructionsitebyanovelporoustitaniumscaffold AT kobatakereiko osseointegrationaspectsofimplantsatthebonereconstructionsitebyanovelporoustitaniumscaffold AT makiharayusuke osseointegrationaspectsofimplantsatthebonereconstructionsitebyanovelporoustitaniumscaffold AT okiyoshifumi osseointegrationaspectsofimplantsatthebonereconstructionsitebyanovelporoustitaniumscaffold AT umeharahanako osseointegrationaspectsofimplantsatthebonereconstructionsitebyanovelporoustitaniumscaffold AT kubotakayasu osseointegrationaspectsofimplantsatthebonereconstructionsitebyanovelporoustitaniumscaffold AT tsugakazuhiro osseointegrationaspectsofimplantsatthebonereconstructionsitebyanovelporoustitaniumscaffold |