Cargando…
Dual Sensitivity—Potentiometric and Fluorimetric—Ion-Selective Membranes
[Image: see text] Classical application of ion-selective membranes is limited to either electrochemical or optical experiments. Herein, the proposed ion-selective membrane system can be used in both modes; each of them offering competitive analytical parameters: high selectivity and linear dependenc...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2021
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8581967/ https://www.ncbi.nlm.nih.gov/pubmed/34699175 http://dx.doi.org/10.1021/acs.analchem.1c03193 |
_version_ | 1784596888964562944 |
---|---|
author | Stelmach, Emilia Maksymiuk, Krzysztof Michalska, Agata |
author_facet | Stelmach, Emilia Maksymiuk, Krzysztof Michalska, Agata |
author_sort | Stelmach, Emilia |
collection | PubMed |
description | [Image: see text] Classical application of ion-selective membranes is limited to either electrochemical or optical experiments. Herein, the proposed ion-selective membrane system can be used in both modes; each of them offering competitive analytical parameters: high selectivity and linear dependence of the signal on logarithm of analyte concentration, high potential stability in potentiometric mode, or applicability for alkaline solutions in optical mode. Incorporation of analyte ions into the membrane results in potentiometric signals, as in a classical system. However, due to the presence of lipophilic positively charged ions, polymer backbones, full saturation of the membrane is prevented even for long contact time with solution. The presence of both positively charged and neutral forms of conducting polymers in the membrane results in high stability of potential readings in time. Optical signal generation is based on polythiophene particulates dispersed within the ion-selective membrane as the optical transducer. An increase of emission is observed with an increase of analyte contents in the sample. |
format | Online Article Text |
id | pubmed-8581967 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-85819672021-11-12 Dual Sensitivity—Potentiometric and Fluorimetric—Ion-Selective Membranes Stelmach, Emilia Maksymiuk, Krzysztof Michalska, Agata Anal Chem [Image: see text] Classical application of ion-selective membranes is limited to either electrochemical or optical experiments. Herein, the proposed ion-selective membrane system can be used in both modes; each of them offering competitive analytical parameters: high selectivity and linear dependence of the signal on logarithm of analyte concentration, high potential stability in potentiometric mode, or applicability for alkaline solutions in optical mode. Incorporation of analyte ions into the membrane results in potentiometric signals, as in a classical system. However, due to the presence of lipophilic positively charged ions, polymer backbones, full saturation of the membrane is prevented even for long contact time with solution. The presence of both positively charged and neutral forms of conducting polymers in the membrane results in high stability of potential readings in time. Optical signal generation is based on polythiophene particulates dispersed within the ion-selective membrane as the optical transducer. An increase of emission is observed with an increase of analyte contents in the sample. American Chemical Society 2021-10-26 2021-11-09 /pmc/articles/PMC8581967/ /pubmed/34699175 http://dx.doi.org/10.1021/acs.analchem.1c03193 Text en © 2021 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Stelmach, Emilia Maksymiuk, Krzysztof Michalska, Agata Dual Sensitivity—Potentiometric and Fluorimetric—Ion-Selective Membranes |
title | Dual Sensitivity—Potentiometric and Fluorimetric—Ion-Selective
Membranes |
title_full | Dual Sensitivity—Potentiometric and Fluorimetric—Ion-Selective
Membranes |
title_fullStr | Dual Sensitivity—Potentiometric and Fluorimetric—Ion-Selective
Membranes |
title_full_unstemmed | Dual Sensitivity—Potentiometric and Fluorimetric—Ion-Selective
Membranes |
title_short | Dual Sensitivity—Potentiometric and Fluorimetric—Ion-Selective
Membranes |
title_sort | dual sensitivity—potentiometric and fluorimetric—ion-selective
membranes |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8581967/ https://www.ncbi.nlm.nih.gov/pubmed/34699175 http://dx.doi.org/10.1021/acs.analchem.1c03193 |
work_keys_str_mv | AT stelmachemilia dualsensitivitypotentiometricandfluorimetricionselectivemembranes AT maksymiukkrzysztof dualsensitivitypotentiometricandfluorimetricionselectivemembranes AT michalskaagata dualsensitivitypotentiometricandfluorimetricionselectivemembranes |