Cargando…

Assessing the value of complex refractive index and particle density for calibration of low-cost particle matter sensor for size-resolved particle count and PM2.5 measurements

Low-cost optical scattering particulate matter (PM) sensors report total or size-specific particle counts and mass concentrations. The PM concentration and size are estimated by the original equipment manufacturer (OEM) proprietary algorithms, which have inherent limitations since particle scatterin...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Ching-Hsuan, He, Jiayang, Austin, Elena, Seto, Edmund, Novosselov, Igor
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8584671/
https://www.ncbi.nlm.nih.gov/pubmed/34762676
http://dx.doi.org/10.1371/journal.pone.0259745
_version_ 1784597505998061568
author Huang, Ching-Hsuan
He, Jiayang
Austin, Elena
Seto, Edmund
Novosselov, Igor
author_facet Huang, Ching-Hsuan
He, Jiayang
Austin, Elena
Seto, Edmund
Novosselov, Igor
author_sort Huang, Ching-Hsuan
collection PubMed
description Low-cost optical scattering particulate matter (PM) sensors report total or size-specific particle counts and mass concentrations. The PM concentration and size are estimated by the original equipment manufacturer (OEM) proprietary algorithms, which have inherent limitations since particle scattering depends on particles’ properties such as size, shape, and complex index of refraction (CRI) as well as environmental parameters such as temperature and relative humidity (RH). As low-cost PM sensors are not able to resolve individual particles, there is a need to characterize and calibrate sensors’ performance under a controlled environment. Here, we present improved calibration algorithms for Plantower PMS A003 sensor for mass indices and size-resolved number concentration. An aerosol chamber experimental protocol was used to evaluate sensor-to-sensor data reproducibility. The calibration was performed using four polydisperse test aerosols. The particle size distribution OEM calibration for PMS A003 sensor did not agree with the reference single particle sizer measurements. For the number concentration calibration, the linear model without adjusting for the aerosol properties and environmental conditions yields an absolute error (NMAE) of ~ 4.0% compared to the reference instrument. The calibration models adjusted for particle CRI and density account for non-linearity in the OEM’s mass concentrations estimates with NMAE within 5.0%. The calibration algorithms developed in this study can be used in indoor air quality monitoring, occupational/industrial exposure assessments, or near-source monitoring scenarios where field calibration might be challenging.
format Online
Article
Text
id pubmed-8584671
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-85846712021-11-12 Assessing the value of complex refractive index and particle density for calibration of low-cost particle matter sensor for size-resolved particle count and PM2.5 measurements Huang, Ching-Hsuan He, Jiayang Austin, Elena Seto, Edmund Novosselov, Igor PLoS One Research Article Low-cost optical scattering particulate matter (PM) sensors report total or size-specific particle counts and mass concentrations. The PM concentration and size are estimated by the original equipment manufacturer (OEM) proprietary algorithms, which have inherent limitations since particle scattering depends on particles’ properties such as size, shape, and complex index of refraction (CRI) as well as environmental parameters such as temperature and relative humidity (RH). As low-cost PM sensors are not able to resolve individual particles, there is a need to characterize and calibrate sensors’ performance under a controlled environment. Here, we present improved calibration algorithms for Plantower PMS A003 sensor for mass indices and size-resolved number concentration. An aerosol chamber experimental protocol was used to evaluate sensor-to-sensor data reproducibility. The calibration was performed using four polydisperse test aerosols. The particle size distribution OEM calibration for PMS A003 sensor did not agree with the reference single particle sizer measurements. For the number concentration calibration, the linear model without adjusting for the aerosol properties and environmental conditions yields an absolute error (NMAE) of ~ 4.0% compared to the reference instrument. The calibration models adjusted for particle CRI and density account for non-linearity in the OEM’s mass concentrations estimates with NMAE within 5.0%. The calibration algorithms developed in this study can be used in indoor air quality monitoring, occupational/industrial exposure assessments, or near-source monitoring scenarios where field calibration might be challenging. Public Library of Science 2021-11-11 /pmc/articles/PMC8584671/ /pubmed/34762676 http://dx.doi.org/10.1371/journal.pone.0259745 Text en © 2021 Huang et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Huang, Ching-Hsuan
He, Jiayang
Austin, Elena
Seto, Edmund
Novosselov, Igor
Assessing the value of complex refractive index and particle density for calibration of low-cost particle matter sensor for size-resolved particle count and PM2.5 measurements
title Assessing the value of complex refractive index and particle density for calibration of low-cost particle matter sensor for size-resolved particle count and PM2.5 measurements
title_full Assessing the value of complex refractive index and particle density for calibration of low-cost particle matter sensor for size-resolved particle count and PM2.5 measurements
title_fullStr Assessing the value of complex refractive index and particle density for calibration of low-cost particle matter sensor for size-resolved particle count and PM2.5 measurements
title_full_unstemmed Assessing the value of complex refractive index and particle density for calibration of low-cost particle matter sensor for size-resolved particle count and PM2.5 measurements
title_short Assessing the value of complex refractive index and particle density for calibration of low-cost particle matter sensor for size-resolved particle count and PM2.5 measurements
title_sort assessing the value of complex refractive index and particle density for calibration of low-cost particle matter sensor for size-resolved particle count and pm2.5 measurements
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8584671/
https://www.ncbi.nlm.nih.gov/pubmed/34762676
http://dx.doi.org/10.1371/journal.pone.0259745
work_keys_str_mv AT huangchinghsuan assessingthevalueofcomplexrefractiveindexandparticledensityforcalibrationoflowcostparticlemattersensorforsizeresolvedparticlecountandpm25measurements
AT hejiayang assessingthevalueofcomplexrefractiveindexandparticledensityforcalibrationoflowcostparticlemattersensorforsizeresolvedparticlecountandpm25measurements
AT austinelena assessingthevalueofcomplexrefractiveindexandparticledensityforcalibrationoflowcostparticlemattersensorforsizeresolvedparticlecountandpm25measurements
AT setoedmund assessingthevalueofcomplexrefractiveindexandparticledensityforcalibrationoflowcostparticlemattersensorforsizeresolvedparticlecountandpm25measurements
AT novosselovigor assessingthevalueofcomplexrefractiveindexandparticledensityforcalibrationoflowcostparticlemattersensorforsizeresolvedparticlecountandpm25measurements