Cargando…
Manual Correction of Voxel Misclassifications in Mesiotemporal Structures Does Not Alter Brain–Behavioral Results in an Episodic Memory Task
Voxel-based morphometry (VBM) is an established method for assessing grey matter volumes across the brain. The quality of magnetic resonance imaging (MRI) and the chosen data preprocessing steps can affect the outcome of VBM analyses. We recognized a lack of publicly available and commonly used prot...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8585064/ https://www.ncbi.nlm.nih.gov/pubmed/34768389 http://dx.doi.org/10.3390/jcm10214869 |
_version_ | 1784597600574373888 |
---|---|
author | Hartmann, Francina Reinhardt, Julia Stippich, Christoph Krumm, Sabine |
author_facet | Hartmann, Francina Reinhardt, Julia Stippich, Christoph Krumm, Sabine |
author_sort | Hartmann, Francina |
collection | PubMed |
description | Voxel-based morphometry (VBM) is an established method for assessing grey matter volumes across the brain. The quality of magnetic resonance imaging (MRI) and the chosen data preprocessing steps can affect the outcome of VBM analyses. We recognized a lack of publicly available and commonly used protocols, which indicates that standardized and optimized preprocessing protocols are needed. This paper focuses on the time- and resource-consuming manual correction of misclassifications of grey matter voxels in cortical structures important in Alzheimer’s dementia. A total of 126 individuals, including 63 patients with very early Alzheimer’s disease and 63 cognitively normal participants, received thorough neuropsychological testing and 3-Tesla MRI. Automated preprocessing of T1 MPRAGE images was performed, and misclassifications of grey matter voxels were manually identified and corrected. In a second run, the manual correction step was skipped. Multiple regression analyses using DARTEL in SPM8 were then conducted with the manually corrected and uncorrected sample, respectively. Manual correction of voxel misclassifications did not have a major impact on the correlation between episodic memory performance and structural brain imaging results. We conclude that, although performing all preprocessing steps remains the gold standard, skipping manual correction of voxel misclassifications is permitted when investigating populations on the Alzheimer’s disease spectrum. |
format | Online Article Text |
id | pubmed-8585064 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-85850642021-11-12 Manual Correction of Voxel Misclassifications in Mesiotemporal Structures Does Not Alter Brain–Behavioral Results in an Episodic Memory Task Hartmann, Francina Reinhardt, Julia Stippich, Christoph Krumm, Sabine J Clin Med Article Voxel-based morphometry (VBM) is an established method for assessing grey matter volumes across the brain. The quality of magnetic resonance imaging (MRI) and the chosen data preprocessing steps can affect the outcome of VBM analyses. We recognized a lack of publicly available and commonly used protocols, which indicates that standardized and optimized preprocessing protocols are needed. This paper focuses on the time- and resource-consuming manual correction of misclassifications of grey matter voxels in cortical structures important in Alzheimer’s dementia. A total of 126 individuals, including 63 patients with very early Alzheimer’s disease and 63 cognitively normal participants, received thorough neuropsychological testing and 3-Tesla MRI. Automated preprocessing of T1 MPRAGE images was performed, and misclassifications of grey matter voxels were manually identified and corrected. In a second run, the manual correction step was skipped. Multiple regression analyses using DARTEL in SPM8 were then conducted with the manually corrected and uncorrected sample, respectively. Manual correction of voxel misclassifications did not have a major impact on the correlation between episodic memory performance and structural brain imaging results. We conclude that, although performing all preprocessing steps remains the gold standard, skipping manual correction of voxel misclassifications is permitted when investigating populations on the Alzheimer’s disease spectrum. MDPI 2021-10-22 /pmc/articles/PMC8585064/ /pubmed/34768389 http://dx.doi.org/10.3390/jcm10214869 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Hartmann, Francina Reinhardt, Julia Stippich, Christoph Krumm, Sabine Manual Correction of Voxel Misclassifications in Mesiotemporal Structures Does Not Alter Brain–Behavioral Results in an Episodic Memory Task |
title | Manual Correction of Voxel Misclassifications in Mesiotemporal Structures Does Not Alter Brain–Behavioral Results in an Episodic Memory Task |
title_full | Manual Correction of Voxel Misclassifications in Mesiotemporal Structures Does Not Alter Brain–Behavioral Results in an Episodic Memory Task |
title_fullStr | Manual Correction of Voxel Misclassifications in Mesiotemporal Structures Does Not Alter Brain–Behavioral Results in an Episodic Memory Task |
title_full_unstemmed | Manual Correction of Voxel Misclassifications in Mesiotemporal Structures Does Not Alter Brain–Behavioral Results in an Episodic Memory Task |
title_short | Manual Correction of Voxel Misclassifications in Mesiotemporal Structures Does Not Alter Brain–Behavioral Results in an Episodic Memory Task |
title_sort | manual correction of voxel misclassifications in mesiotemporal structures does not alter brain–behavioral results in an episodic memory task |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8585064/ https://www.ncbi.nlm.nih.gov/pubmed/34768389 http://dx.doi.org/10.3390/jcm10214869 |
work_keys_str_mv | AT hartmannfrancina manualcorrectionofvoxelmisclassificationsinmesiotemporalstructuresdoesnotalterbrainbehavioralresultsinanepisodicmemorytask AT reinhardtjulia manualcorrectionofvoxelmisclassificationsinmesiotemporalstructuresdoesnotalterbrainbehavioralresultsinanepisodicmemorytask AT stippichchristoph manualcorrectionofvoxelmisclassificationsinmesiotemporalstructuresdoesnotalterbrainbehavioralresultsinanepisodicmemorytask AT krummsabine manualcorrectionofvoxelmisclassificationsinmesiotemporalstructuresdoesnotalterbrainbehavioralresultsinanepisodicmemorytask |