Toothbrush Abrasion of Restorations Fabricated with Flowable Resin Composites with Different Viscosities In Vitro
The purpose of this study was to examine toothbrush-induced abrasion of resin composite restorations fabricated with flowable resin composites of different viscosities in vitro. In this study, six types of flowable resin composites with different flowability (Beautifil Flow F02, F02; Beautifil Flow...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8585295/ https://www.ncbi.nlm.nih.gov/pubmed/34771960 http://dx.doi.org/10.3390/ma14216436 |
_version_ | 1784597656170921984 |
---|---|
author | Miyano, Yuko Suzuki, Masaya Shinkai, Koichi |
author_facet | Miyano, Yuko Suzuki, Masaya Shinkai, Koichi |
author_sort | Miyano, Yuko |
collection | PubMed |
description | The purpose of this study was to examine toothbrush-induced abrasion of resin composite restorations fabricated with flowable resin composites of different viscosities in vitro. In this study, six types of flowable resin composites with different flowability (Beautifil Flow F02, F02; Beautifil Flow F10, F10; Beautifil Flow Plus F00, P00; Beautifil Flow Plus F03, P03; Beautifil Flow Plus X F00, X00; and Beautifil Flow Plus X F03, X03) were used. For the toothbrush abrasion test, the standard cavity (4 mm in diameter and 2 mm in depth) formed on the ceramic block was filled with each flowable resin composite (n = 10) and brushed for up to 40,000 strokes in a suspension containing commercial toothpaste under the conditions of 500 g load, 60 strokes/min, and 30 mm stroke distance. After every 10,000 strokes, the brushed surface of the specimen was impressed with a silicone rubber material. The amount of toothbrush-induced abrasion observed on each impression of the specimen was measured using a wide-area 3D measurement device (n = 10). The viscosity was determined using a cone-and-plate rotational measurement system. Because of the effect of different shear rates on viscosity and clinical use, the values 1.0 and 2.0 s(−1) were adopted as data (n = 6). In this study, the results of the toothbrush abrasion test demonstrated no significant differences in the amount of toothbrush-induced abrasion among flowable resin composites used (p > 0.05). No significant correlation was reported between toothbrush-induced abrasion and viscosities of flowable resin composites. |
format | Online Article Text |
id | pubmed-8585295 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-85852952021-11-12 Toothbrush Abrasion of Restorations Fabricated with Flowable Resin Composites with Different Viscosities In Vitro Miyano, Yuko Suzuki, Masaya Shinkai, Koichi Materials (Basel) Article The purpose of this study was to examine toothbrush-induced abrasion of resin composite restorations fabricated with flowable resin composites of different viscosities in vitro. In this study, six types of flowable resin composites with different flowability (Beautifil Flow F02, F02; Beautifil Flow F10, F10; Beautifil Flow Plus F00, P00; Beautifil Flow Plus F03, P03; Beautifil Flow Plus X F00, X00; and Beautifil Flow Plus X F03, X03) were used. For the toothbrush abrasion test, the standard cavity (4 mm in diameter and 2 mm in depth) formed on the ceramic block was filled with each flowable resin composite (n = 10) and brushed for up to 40,000 strokes in a suspension containing commercial toothpaste under the conditions of 500 g load, 60 strokes/min, and 30 mm stroke distance. After every 10,000 strokes, the brushed surface of the specimen was impressed with a silicone rubber material. The amount of toothbrush-induced abrasion observed on each impression of the specimen was measured using a wide-area 3D measurement device (n = 10). The viscosity was determined using a cone-and-plate rotational measurement system. Because of the effect of different shear rates on viscosity and clinical use, the values 1.0 and 2.0 s(−1) were adopted as data (n = 6). In this study, the results of the toothbrush abrasion test demonstrated no significant differences in the amount of toothbrush-induced abrasion among flowable resin composites used (p > 0.05). No significant correlation was reported between toothbrush-induced abrasion and viscosities of flowable resin composites. MDPI 2021-10-27 /pmc/articles/PMC8585295/ /pubmed/34771960 http://dx.doi.org/10.3390/ma14216436 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Miyano, Yuko Suzuki, Masaya Shinkai, Koichi Toothbrush Abrasion of Restorations Fabricated with Flowable Resin Composites with Different Viscosities In Vitro |
title | Toothbrush Abrasion of Restorations Fabricated with Flowable Resin Composites with Different Viscosities In Vitro |
title_full | Toothbrush Abrasion of Restorations Fabricated with Flowable Resin Composites with Different Viscosities In Vitro |
title_fullStr | Toothbrush Abrasion of Restorations Fabricated with Flowable Resin Composites with Different Viscosities In Vitro |
title_full_unstemmed | Toothbrush Abrasion of Restorations Fabricated with Flowable Resin Composites with Different Viscosities In Vitro |
title_short | Toothbrush Abrasion of Restorations Fabricated with Flowable Resin Composites with Different Viscosities In Vitro |
title_sort | toothbrush abrasion of restorations fabricated with flowable resin composites with different viscosities in vitro |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8585295/ https://www.ncbi.nlm.nih.gov/pubmed/34771960 http://dx.doi.org/10.3390/ma14216436 |
work_keys_str_mv | AT miyanoyuko toothbrushabrasionofrestorationsfabricatedwithflowableresincompositeswithdifferentviscositiesinvitro AT suzukimasaya toothbrushabrasionofrestorationsfabricatedwithflowableresincompositeswithdifferentviscositiesinvitro AT shinkaikoichi toothbrushabrasionofrestorationsfabricatedwithflowableresincompositeswithdifferentviscositiesinvitro |