Cargando…

Evaluation of Quality of Obturation Using Two Different Rotary Files and Hand Files in Primary Teeth: A Randomized Controlled Trial

AIM AND OBJECTIVE: To estimate the obturation quality and instrumentation time on comparing traditional hand files and two rotary file types during root canal instrumentation in deciduous molars. MATERIALS AND METHODS: Forty-five deciduous mandibular molars were taken and randomly allotted to three...

Descripción completa

Detalles Bibliográficos
Autores principales: Preethy, Neethu Ann, Jeevanandan, Ganesh, Mathew, Mebin George, Subramanian, Erulappan M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Jaypee Brothers Medical Publishers 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8585900/
https://www.ncbi.nlm.nih.gov/pubmed/34824498
http://dx.doi.org/10.5005/jp-journals-10005-1990
_version_ 1784597781797666816
author Preethy, Neethu Ann
Jeevanandan, Ganesh
Mathew, Mebin George
Subramanian, Erulappan M
author_facet Preethy, Neethu Ann
Jeevanandan, Ganesh
Mathew, Mebin George
Subramanian, Erulappan M
author_sort Preethy, Neethu Ann
collection PubMed
description AIM AND OBJECTIVE: To estimate the obturation quality and instrumentation time on comparing traditional hand files and two rotary file types during root canal instrumentation in deciduous molars. MATERIALS AND METHODS: Forty-five deciduous mandibular molars were taken and randomly allotted to three groups (n = 15). Group I: K-hand files, group II: ProTaper Gold rotary file, and group III: Kedo-SG Blue rotary files. Before and after root canal instrumentation, standardized digital radiography was taken and the instrumentation time was also noted. The recorded data were then subjected to statistical analysis utilizing SPSS Software version 22.0. To compare the instrumentation time and quality of obturation between the groups, a Chi-square test and ANOVA with the level of significance at 0.05 were employed. RESULTS: There was no significant difference recorded with reference to the quality of obturation (p > 0.05). However, the difference was noticed to be statistically significant when the instrumentation time between the two rotary groups and the manual instrumentation groups was taken into account (p < 0.05). The rotary systems ProTaper Gold and Kedo-SG Blue exhibited a significantly less instrumentation time on comparing with that of the hand files. CONCLUSION: Concerning the quality of obturation, all three file groups demonstrated almost a similar performance. However, there was a significant difference noticed in the instrumentation time with the use of manual instrumentation in comparison to rotary instrumentation in deciduous teeth. HOW TO CITE THIS ARTICLE: Preethy NA, Jeevanandan G, Mathew MG, et al. Evaluation of Quality of Obturation Using Two Different Rotary Files and Hand Files in Primary Teeth: A Randomized Controlled Trial. Int J Clin Pediatr Dent 2021;14(4):471–474.
format Online
Article
Text
id pubmed-8585900
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Jaypee Brothers Medical Publishers
record_format MEDLINE/PubMed
spelling pubmed-85859002021-11-24 Evaluation of Quality of Obturation Using Two Different Rotary Files and Hand Files in Primary Teeth: A Randomized Controlled Trial Preethy, Neethu Ann Jeevanandan, Ganesh Mathew, Mebin George Subramanian, Erulappan M Int J Clin Pediatr Dent Research Article AIM AND OBJECTIVE: To estimate the obturation quality and instrumentation time on comparing traditional hand files and two rotary file types during root canal instrumentation in deciduous molars. MATERIALS AND METHODS: Forty-five deciduous mandibular molars were taken and randomly allotted to three groups (n = 15). Group I: K-hand files, group II: ProTaper Gold rotary file, and group III: Kedo-SG Blue rotary files. Before and after root canal instrumentation, standardized digital radiography was taken and the instrumentation time was also noted. The recorded data were then subjected to statistical analysis utilizing SPSS Software version 22.0. To compare the instrumentation time and quality of obturation between the groups, a Chi-square test and ANOVA with the level of significance at 0.05 were employed. RESULTS: There was no significant difference recorded with reference to the quality of obturation (p > 0.05). However, the difference was noticed to be statistically significant when the instrumentation time between the two rotary groups and the manual instrumentation groups was taken into account (p < 0.05). The rotary systems ProTaper Gold and Kedo-SG Blue exhibited a significantly less instrumentation time on comparing with that of the hand files. CONCLUSION: Concerning the quality of obturation, all three file groups demonstrated almost a similar performance. However, there was a significant difference noticed in the instrumentation time with the use of manual instrumentation in comparison to rotary instrumentation in deciduous teeth. HOW TO CITE THIS ARTICLE: Preethy NA, Jeevanandan G, Mathew MG, et al. Evaluation of Quality of Obturation Using Two Different Rotary Files and Hand Files in Primary Teeth: A Randomized Controlled Trial. Int J Clin Pediatr Dent 2021;14(4):471–474. Jaypee Brothers Medical Publishers 2021 /pmc/articles/PMC8585900/ /pubmed/34824498 http://dx.doi.org/10.5005/jp-journals-10005-1990 Text en Copyright © 2021; Jaypee Brothers Medical Publishers (P) Ltd. https://creativecommons.org/licenses/by-nc/4.0/© The Author(s). 2021 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Preethy, Neethu Ann
Jeevanandan, Ganesh
Mathew, Mebin George
Subramanian, Erulappan M
Evaluation of Quality of Obturation Using Two Different Rotary Files and Hand Files in Primary Teeth: A Randomized Controlled Trial
title Evaluation of Quality of Obturation Using Two Different Rotary Files and Hand Files in Primary Teeth: A Randomized Controlled Trial
title_full Evaluation of Quality of Obturation Using Two Different Rotary Files and Hand Files in Primary Teeth: A Randomized Controlled Trial
title_fullStr Evaluation of Quality of Obturation Using Two Different Rotary Files and Hand Files in Primary Teeth: A Randomized Controlled Trial
title_full_unstemmed Evaluation of Quality of Obturation Using Two Different Rotary Files and Hand Files in Primary Teeth: A Randomized Controlled Trial
title_short Evaluation of Quality of Obturation Using Two Different Rotary Files and Hand Files in Primary Teeth: A Randomized Controlled Trial
title_sort evaluation of quality of obturation using two different rotary files and hand files in primary teeth: a randomized controlled trial
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8585900/
https://www.ncbi.nlm.nih.gov/pubmed/34824498
http://dx.doi.org/10.5005/jp-journals-10005-1990
work_keys_str_mv AT preethyneethuann evaluationofqualityofobturationusingtwodifferentrotaryfilesandhandfilesinprimaryteetharandomizedcontrolledtrial
AT jeevanandanganesh evaluationofqualityofobturationusingtwodifferentrotaryfilesandhandfilesinprimaryteetharandomizedcontrolledtrial
AT mathewmebingeorge evaluationofqualityofobturationusingtwodifferentrotaryfilesandhandfilesinprimaryteetharandomizedcontrolledtrial
AT subramanianerulappanm evaluationofqualityofobturationusingtwodifferentrotaryfilesandhandfilesinprimaryteetharandomizedcontrolledtrial