Cargando…

No difference in mid-term outcome after superior vs. anteroinferior plate position for displaced midshaft clavicle fractures

To compare outcomes, complications, revisions, and rates of implant removal of superior compared to anteroinferior plating in displaced midshaft clavicle fractures at mid-term follow-up. We retrospectively reviewed 79 patients who underwent operative treatment for displaced midshaft clavicle fractur...

Descripción completa

Detalles Bibliográficos
Autores principales: Nolte, Philip-Christian, Tross, Anna-Katharina, Studniorz, Julia, Grützner, Paul-Alfred, Guehring, Thorsten, Schnetzke, Marc
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8586364/
https://www.ncbi.nlm.nih.gov/pubmed/34764395
http://dx.doi.org/10.1038/s41598-021-01625-4
_version_ 1784597876447379456
author Nolte, Philip-Christian
Tross, Anna-Katharina
Studniorz, Julia
Grützner, Paul-Alfred
Guehring, Thorsten
Schnetzke, Marc
author_facet Nolte, Philip-Christian
Tross, Anna-Katharina
Studniorz, Julia
Grützner, Paul-Alfred
Guehring, Thorsten
Schnetzke, Marc
author_sort Nolte, Philip-Christian
collection PubMed
description To compare outcomes, complications, revisions, and rates of implant removal of superior compared to anteroinferior plating in displaced midshaft clavicle fractures at mid-term follow-up. We retrospectively reviewed 79 patients who underwent operative treatment for displaced midshaft clavicle fractures (Group A: 28 patients with superior plating; Group B: 51 patients with anteroinferior plating) that were at least 2 years postoperatively. Adjusted Constant Score (aCS), Visual Analog Scale (VAS), and Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score were compared. Bone union, implant removal, complications and revision surgeries were assessed. Group A had a significantly higher aCS compared to group B (90, IQR: 85.0–91.0 vs. 91, IQR: 90.0–93.0; P = 0.037). No significant differences between groups were seen in VAS (P = 0.283) and QuickDASH (P = 0.384). Bone union was achieved in 76 patients (96.2%) with no significant differences between groups (Group A: 96.4% vs. Group B: 96.1%; P > 0.999). There were no significant differences in implant removal rates (Group A: 60.7% vs. Group B: 66.7%; P = 0.630), complications (Group A: 46.4% vs. Group B: 31.4%; P = 0.226) and revisions (Group A: 25% vs. Group B: 9.8%; P = 0.102). Superior and anteroinferior plating result in high bone union rates and good clinical outcomes with similar rates of plate removal.
format Online
Article
Text
id pubmed-8586364
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-85863642021-11-16 No difference in mid-term outcome after superior vs. anteroinferior plate position for displaced midshaft clavicle fractures Nolte, Philip-Christian Tross, Anna-Katharina Studniorz, Julia Grützner, Paul-Alfred Guehring, Thorsten Schnetzke, Marc Sci Rep Article To compare outcomes, complications, revisions, and rates of implant removal of superior compared to anteroinferior plating in displaced midshaft clavicle fractures at mid-term follow-up. We retrospectively reviewed 79 patients who underwent operative treatment for displaced midshaft clavicle fractures (Group A: 28 patients with superior plating; Group B: 51 patients with anteroinferior plating) that were at least 2 years postoperatively. Adjusted Constant Score (aCS), Visual Analog Scale (VAS), and Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score were compared. Bone union, implant removal, complications and revision surgeries were assessed. Group A had a significantly higher aCS compared to group B (90, IQR: 85.0–91.0 vs. 91, IQR: 90.0–93.0; P = 0.037). No significant differences between groups were seen in VAS (P = 0.283) and QuickDASH (P = 0.384). Bone union was achieved in 76 patients (96.2%) with no significant differences between groups (Group A: 96.4% vs. Group B: 96.1%; P > 0.999). There were no significant differences in implant removal rates (Group A: 60.7% vs. Group B: 66.7%; P = 0.630), complications (Group A: 46.4% vs. Group B: 31.4%; P = 0.226) and revisions (Group A: 25% vs. Group B: 9.8%; P = 0.102). Superior and anteroinferior plating result in high bone union rates and good clinical outcomes with similar rates of plate removal. Nature Publishing Group UK 2021-11-11 /pmc/articles/PMC8586364/ /pubmed/34764395 http://dx.doi.org/10.1038/s41598-021-01625-4 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Nolte, Philip-Christian
Tross, Anna-Katharina
Studniorz, Julia
Grützner, Paul-Alfred
Guehring, Thorsten
Schnetzke, Marc
No difference in mid-term outcome after superior vs. anteroinferior plate position for displaced midshaft clavicle fractures
title No difference in mid-term outcome after superior vs. anteroinferior plate position for displaced midshaft clavicle fractures
title_full No difference in mid-term outcome after superior vs. anteroinferior plate position for displaced midshaft clavicle fractures
title_fullStr No difference in mid-term outcome after superior vs. anteroinferior plate position for displaced midshaft clavicle fractures
title_full_unstemmed No difference in mid-term outcome after superior vs. anteroinferior plate position for displaced midshaft clavicle fractures
title_short No difference in mid-term outcome after superior vs. anteroinferior plate position for displaced midshaft clavicle fractures
title_sort no difference in mid-term outcome after superior vs. anteroinferior plate position for displaced midshaft clavicle fractures
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8586364/
https://www.ncbi.nlm.nih.gov/pubmed/34764395
http://dx.doi.org/10.1038/s41598-021-01625-4
work_keys_str_mv AT noltephilipchristian nodifferenceinmidtermoutcomeaftersuperiorvsanteroinferiorplatepositionfordisplacedmidshaftclaviclefractures
AT trossannakatharina nodifferenceinmidtermoutcomeaftersuperiorvsanteroinferiorplatepositionfordisplacedmidshaftclaviclefractures
AT studniorzjulia nodifferenceinmidtermoutcomeaftersuperiorvsanteroinferiorplatepositionfordisplacedmidshaftclaviclefractures
AT grutznerpaulalfred nodifferenceinmidtermoutcomeaftersuperiorvsanteroinferiorplatepositionfordisplacedmidshaftclaviclefractures
AT guehringthorsten nodifferenceinmidtermoutcomeaftersuperiorvsanteroinferiorplatepositionfordisplacedmidshaftclaviclefractures
AT schnetzkemarc nodifferenceinmidtermoutcomeaftersuperiorvsanteroinferiorplatepositionfordisplacedmidshaftclaviclefractures