Cargando…

Utility of the oxygen pulse in the diagnosis of obstructive coronary artery disease in physically fit patients

Cardiopulmonary exercise testing (CPET) guidelines recommend analysis of the oxygen (O(2)) pulse for a late exercise plateau in evaluation for obstructive coronary artery disease (OCAD). However, whether this O(2) pulse trajectory is within the range of normal has been debated, and the diagnostic pe...

Descripción completa

Detalles Bibliográficos
Autores principales: Petek, Bradley J., Churchill, Timothy W., Sawalla Guseh, J., Loomer, Garrett, Gustus, Sarah K., Lewis, Gregory D., Weiner, Rory B., Baggish, Aaron L., Wasfy, Meagan M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8587175/
https://www.ncbi.nlm.nih.gov/pubmed/34767313
http://dx.doi.org/10.14814/phy2.15105
_version_ 1784598084809916416
author Petek, Bradley J.
Churchill, Timothy W.
Sawalla Guseh, J.
Loomer, Garrett
Gustus, Sarah K.
Lewis, Gregory D.
Weiner, Rory B.
Baggish, Aaron L.
Wasfy, Meagan M.
author_facet Petek, Bradley J.
Churchill, Timothy W.
Sawalla Guseh, J.
Loomer, Garrett
Gustus, Sarah K.
Lewis, Gregory D.
Weiner, Rory B.
Baggish, Aaron L.
Wasfy, Meagan M.
author_sort Petek, Bradley J.
collection PubMed
description Cardiopulmonary exercise testing (CPET) guidelines recommend analysis of the oxygen (O(2)) pulse for a late exercise plateau in evaluation for obstructive coronary artery disease (OCAD). However, whether this O(2) pulse trajectory is within the range of normal has been debated, and the diagnostic performance of the O(2) pulse for OCAD in physically fit individuals, in whom [Formula: see text] may be more likely to plateau, has not been evaluated. Using prospectively collected data from a sports cardiology program, patients were identified who were free of other cardiac disease and underwent clinically‐indicated CPET within 90 days of invasive or computed tomography coronary angiography. The diagnostic performance of quantitative O(2) pulse metrics (late exercise slope, proportional change in slope during late exercise) and qualitative assessment for O(2) pulse plateau to predict OCAD was assessed. Among 104 patients (age:56 ± 12 years, 30% female, peak [Formula: see text] 119 ± 34% predicted), the diagnostic performance for OCAD (n = 24,23%) was poor for both quantitative and qualitative metrics reflecting an O(2) pulse plateau (late exercise slope: AUC = 0.55, sensitivity = 68%, specificity = 41%; proportional change in slope: AUC = 0.55, sensitivity = 91%, specificity = 18%; visual plateau/decline: AUC = 0.51, sensitivity = 33%, specificity = 67%). When O(2) pulse parameters were added to the electrocardiogram, the change in AUC was minimal (−0.01 to +0.02, p ≥ 0.05). Those patients without OCAD with a plateau or decline in O(2) pulse were fitter than those with linear augmentation (peak [Formula: see text] 133 ± 31% vs. 114 ± 36% predicted, p < 0.05) and had a longer exercise ramp time (9.5 ± 3.2 vs. 8.0 ± 2.5 min, p < 0.05). Overall, a plateau in O(2) pulse was not a useful predictor of OCAD in a physically fit population, indicating that the O(2) pulse should be integrated with other CPET parameters and may reflect a physiologic limitation of stroke volume and/or O(2) extraction during intense exercise.
format Online
Article
Text
id pubmed-8587175
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-85871752021-11-18 Utility of the oxygen pulse in the diagnosis of obstructive coronary artery disease in physically fit patients Petek, Bradley J. Churchill, Timothy W. Sawalla Guseh, J. Loomer, Garrett Gustus, Sarah K. Lewis, Gregory D. Weiner, Rory B. Baggish, Aaron L. Wasfy, Meagan M. Physiol Rep Original Articles Cardiopulmonary exercise testing (CPET) guidelines recommend analysis of the oxygen (O(2)) pulse for a late exercise plateau in evaluation for obstructive coronary artery disease (OCAD). However, whether this O(2) pulse trajectory is within the range of normal has been debated, and the diagnostic performance of the O(2) pulse for OCAD in physically fit individuals, in whom [Formula: see text] may be more likely to plateau, has not been evaluated. Using prospectively collected data from a sports cardiology program, patients were identified who were free of other cardiac disease and underwent clinically‐indicated CPET within 90 days of invasive or computed tomography coronary angiography. The diagnostic performance of quantitative O(2) pulse metrics (late exercise slope, proportional change in slope during late exercise) and qualitative assessment for O(2) pulse plateau to predict OCAD was assessed. Among 104 patients (age:56 ± 12 years, 30% female, peak [Formula: see text] 119 ± 34% predicted), the diagnostic performance for OCAD (n = 24,23%) was poor for both quantitative and qualitative metrics reflecting an O(2) pulse plateau (late exercise slope: AUC = 0.55, sensitivity = 68%, specificity = 41%; proportional change in slope: AUC = 0.55, sensitivity = 91%, specificity = 18%; visual plateau/decline: AUC = 0.51, sensitivity = 33%, specificity = 67%). When O(2) pulse parameters were added to the electrocardiogram, the change in AUC was minimal (−0.01 to +0.02, p ≥ 0.05). Those patients without OCAD with a plateau or decline in O(2) pulse were fitter than those with linear augmentation (peak [Formula: see text] 133 ± 31% vs. 114 ± 36% predicted, p < 0.05) and had a longer exercise ramp time (9.5 ± 3.2 vs. 8.0 ± 2.5 min, p < 0.05). Overall, a plateau in O(2) pulse was not a useful predictor of OCAD in a physically fit population, indicating that the O(2) pulse should be integrated with other CPET parameters and may reflect a physiologic limitation of stroke volume and/or O(2) extraction during intense exercise. John Wiley and Sons Inc. 2021-11-12 /pmc/articles/PMC8587175/ /pubmed/34767313 http://dx.doi.org/10.14814/phy2.15105 Text en © 2021 The Authors. Physiological Reports published by Wiley Periodicals LLC on behalf of The Physiological Society and the American Physiological Society https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Petek, Bradley J.
Churchill, Timothy W.
Sawalla Guseh, J.
Loomer, Garrett
Gustus, Sarah K.
Lewis, Gregory D.
Weiner, Rory B.
Baggish, Aaron L.
Wasfy, Meagan M.
Utility of the oxygen pulse in the diagnosis of obstructive coronary artery disease in physically fit patients
title Utility of the oxygen pulse in the diagnosis of obstructive coronary artery disease in physically fit patients
title_full Utility of the oxygen pulse in the diagnosis of obstructive coronary artery disease in physically fit patients
title_fullStr Utility of the oxygen pulse in the diagnosis of obstructive coronary artery disease in physically fit patients
title_full_unstemmed Utility of the oxygen pulse in the diagnosis of obstructive coronary artery disease in physically fit patients
title_short Utility of the oxygen pulse in the diagnosis of obstructive coronary artery disease in physically fit patients
title_sort utility of the oxygen pulse in the diagnosis of obstructive coronary artery disease in physically fit patients
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8587175/
https://www.ncbi.nlm.nih.gov/pubmed/34767313
http://dx.doi.org/10.14814/phy2.15105
work_keys_str_mv AT petekbradleyj utilityoftheoxygenpulseinthediagnosisofobstructivecoronaryarterydiseaseinphysicallyfitpatients
AT churchilltimothyw utilityoftheoxygenpulseinthediagnosisofobstructivecoronaryarterydiseaseinphysicallyfitpatients
AT sawallagusehj utilityoftheoxygenpulseinthediagnosisofobstructivecoronaryarterydiseaseinphysicallyfitpatients
AT loomergarrett utilityoftheoxygenpulseinthediagnosisofobstructivecoronaryarterydiseaseinphysicallyfitpatients
AT gustussarahk utilityoftheoxygenpulseinthediagnosisofobstructivecoronaryarterydiseaseinphysicallyfitpatients
AT lewisgregoryd utilityoftheoxygenpulseinthediagnosisofobstructivecoronaryarterydiseaseinphysicallyfitpatients
AT weinerroryb utilityoftheoxygenpulseinthediagnosisofobstructivecoronaryarterydiseaseinphysicallyfitpatients
AT baggishaaronl utilityoftheoxygenpulseinthediagnosisofobstructivecoronaryarterydiseaseinphysicallyfitpatients
AT wasfymeaganm utilityoftheoxygenpulseinthediagnosisofobstructivecoronaryarterydiseaseinphysicallyfitpatients