Cargando…
Improved Environment-Aware–Based Noise Reduction System for Cochlear Implant Users Based on a Knowledge Transfer Approach: Development and Usability Study
BACKGROUND: Cochlear implant technology is a well-known approach to help deaf individuals hear speech again and can improve speech intelligibility in quiet conditions; however, it still has room for improvement in noisy conditions. More recently, it has been proven that deep learning–based noise red...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
JMIR Publications
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8587190/ https://www.ncbi.nlm.nih.gov/pubmed/34709193 http://dx.doi.org/10.2196/25460 |
_version_ | 1784598089944793088 |
---|---|
author | Li, Lieber Po-Hung Han, Ji-Yan Zheng, Wei-Zhong Huang, Ren-Jie Lai, Ying-Hui |
author_facet | Li, Lieber Po-Hung Han, Ji-Yan Zheng, Wei-Zhong Huang, Ren-Jie Lai, Ying-Hui |
author_sort | Li, Lieber Po-Hung |
collection | PubMed |
description | BACKGROUND: Cochlear implant technology is a well-known approach to help deaf individuals hear speech again and can improve speech intelligibility in quiet conditions; however, it still has room for improvement in noisy conditions. More recently, it has been proven that deep learning–based noise reduction, such as noise classification and deep denoising autoencoder (NC+DDAE), can benefit the intelligibility performance of patients with cochlear implants compared to classical noise reduction algorithms. OBJECTIVE: Following the successful implementation of the NC+DDAE model in our previous study, this study aimed to propose an advanced noise reduction system using knowledge transfer technology, called NC+DDAE_T; examine the proposed NC+DDAE_T noise reduction system using objective evaluations and subjective listening tests; and investigate which layer substitution of the knowledge transfer technology in the NC+DDAE_T noise reduction system provides the best outcome. METHODS: The knowledge transfer technology was adopted to reduce the number of parameters of the NC+DDAE_T compared with the NC+DDAE. We investigated which layer should be substituted using short-time objective intelligibility and perceptual evaluation of speech quality scores as well as t-distributed stochastic neighbor embedding to visualize the features in each model layer. Moreover, we enrolled 10 cochlear implant users for listening tests to evaluate the benefits of the newly developed NC+DDAE_T. RESULTS: The experimental results showed that substituting the middle layer (ie, the second layer in this study) of the noise-independent DDAE (NI-DDAE) model achieved the best performance gain regarding short-time objective intelligibility and perceptual evaluation of speech quality scores. Therefore, the parameters of layer 3 in the NI-DDAE were chosen to be replaced, thereby establishing the NC+DDAE_T. Both objective and listening test results showed that the proposed NC+DDAE_T noise reduction system achieved similar performances compared with the previous NC+DDAE in several noisy test conditions. However, the proposed NC+DDAE_T only required a quarter of the number of parameters compared to the NC+DDAE. CONCLUSIONS: This study demonstrated that knowledge transfer technology can help reduce the number of parameters in an NC+DDAE while keeping similar performance rates. This suggests that the proposed NC+DDAE_T model may reduce the implementation costs of this noise reduction system and provide more benefits for cochlear implant users. |
format | Online Article Text |
id | pubmed-8587190 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | JMIR Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-85871902021-12-07 Improved Environment-Aware–Based Noise Reduction System for Cochlear Implant Users Based on a Knowledge Transfer Approach: Development and Usability Study Li, Lieber Po-Hung Han, Ji-Yan Zheng, Wei-Zhong Huang, Ren-Jie Lai, Ying-Hui J Med Internet Res Original Paper BACKGROUND: Cochlear implant technology is a well-known approach to help deaf individuals hear speech again and can improve speech intelligibility in quiet conditions; however, it still has room for improvement in noisy conditions. More recently, it has been proven that deep learning–based noise reduction, such as noise classification and deep denoising autoencoder (NC+DDAE), can benefit the intelligibility performance of patients with cochlear implants compared to classical noise reduction algorithms. OBJECTIVE: Following the successful implementation of the NC+DDAE model in our previous study, this study aimed to propose an advanced noise reduction system using knowledge transfer technology, called NC+DDAE_T; examine the proposed NC+DDAE_T noise reduction system using objective evaluations and subjective listening tests; and investigate which layer substitution of the knowledge transfer technology in the NC+DDAE_T noise reduction system provides the best outcome. METHODS: The knowledge transfer technology was adopted to reduce the number of parameters of the NC+DDAE_T compared with the NC+DDAE. We investigated which layer should be substituted using short-time objective intelligibility and perceptual evaluation of speech quality scores as well as t-distributed stochastic neighbor embedding to visualize the features in each model layer. Moreover, we enrolled 10 cochlear implant users for listening tests to evaluate the benefits of the newly developed NC+DDAE_T. RESULTS: The experimental results showed that substituting the middle layer (ie, the second layer in this study) of the noise-independent DDAE (NI-DDAE) model achieved the best performance gain regarding short-time objective intelligibility and perceptual evaluation of speech quality scores. Therefore, the parameters of layer 3 in the NI-DDAE were chosen to be replaced, thereby establishing the NC+DDAE_T. Both objective and listening test results showed that the proposed NC+DDAE_T noise reduction system achieved similar performances compared with the previous NC+DDAE in several noisy test conditions. However, the proposed NC+DDAE_T only required a quarter of the number of parameters compared to the NC+DDAE. CONCLUSIONS: This study demonstrated that knowledge transfer technology can help reduce the number of parameters in an NC+DDAE while keeping similar performance rates. This suggests that the proposed NC+DDAE_T model may reduce the implementation costs of this noise reduction system and provide more benefits for cochlear implant users. JMIR Publications 2021-10-28 /pmc/articles/PMC8587190/ /pubmed/34709193 http://dx.doi.org/10.2196/25460 Text en ©Lieber Po-Hung Li, Ji-Yan Han, Wei-Zhong Zheng, Ren-Jie Huang, Ying-Hui Lai. Originally published in the Journal of Medical Internet Research (https://www.jmir.org), 28.10.2021. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in the Journal of Medical Internet Research, is properly cited. The complete bibliographic information, a link to the original publication on https://www.jmir.org/, as well as this copyright and license information must be included. |
spellingShingle | Original Paper Li, Lieber Po-Hung Han, Ji-Yan Zheng, Wei-Zhong Huang, Ren-Jie Lai, Ying-Hui Improved Environment-Aware–Based Noise Reduction System for Cochlear Implant Users Based on a Knowledge Transfer Approach: Development and Usability Study |
title | Improved Environment-Aware–Based Noise Reduction System for Cochlear Implant Users Based on a Knowledge Transfer Approach: Development and Usability Study |
title_full | Improved Environment-Aware–Based Noise Reduction System for Cochlear Implant Users Based on a Knowledge Transfer Approach: Development and Usability Study |
title_fullStr | Improved Environment-Aware–Based Noise Reduction System for Cochlear Implant Users Based on a Knowledge Transfer Approach: Development and Usability Study |
title_full_unstemmed | Improved Environment-Aware–Based Noise Reduction System for Cochlear Implant Users Based on a Knowledge Transfer Approach: Development and Usability Study |
title_short | Improved Environment-Aware–Based Noise Reduction System for Cochlear Implant Users Based on a Knowledge Transfer Approach: Development and Usability Study |
title_sort | improved environment-aware–based noise reduction system for cochlear implant users based on a knowledge transfer approach: development and usability study |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8587190/ https://www.ncbi.nlm.nih.gov/pubmed/34709193 http://dx.doi.org/10.2196/25460 |
work_keys_str_mv | AT lilieberpohung improvedenvironmentawarebasednoisereductionsystemforcochlearimplantusersbasedonaknowledgetransferapproachdevelopmentandusabilitystudy AT hanjiyan improvedenvironmentawarebasednoisereductionsystemforcochlearimplantusersbasedonaknowledgetransferapproachdevelopmentandusabilitystudy AT zhengweizhong improvedenvironmentawarebasednoisereductionsystemforcochlearimplantusersbasedonaknowledgetransferapproachdevelopmentandusabilitystudy AT huangrenjie improvedenvironmentawarebasednoisereductionsystemforcochlearimplantusersbasedonaknowledgetransferapproachdevelopmentandusabilitystudy AT laiyinghui improvedenvironmentawarebasednoisereductionsystemforcochlearimplantusersbasedonaknowledgetransferapproachdevelopmentandusabilitystudy |