Cargando…
Influence of Toothbrush Abrasion and Surface Treatments on Roughness and Gloss of Polymer-Infiltrated Ceramics
The aim of this study was to compare the surface roughness and gloss of polymer-infiltrated ceramics after simulated in vitro toothbrushing in different storage mediums. Four polymer- infiltrated ceramics were evaluated, Lava ultimate (LU), Vita enamic (EN), Shofu (SH), and Crystal ultra (CU). The c...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8587314/ https://www.ncbi.nlm.nih.gov/pubmed/34771250 http://dx.doi.org/10.3390/polym13213694 |
_version_ | 1784598111217254400 |
---|---|
author | Labban, Nawaf Al Amri, Mohammad D. Alnafaiy, Sarah M. Alhijji, Saleh M. Alenizy, Mohammad A. Iskandar, Mounir Feitosa, Sabrina |
author_facet | Labban, Nawaf Al Amri, Mohammad D. Alnafaiy, Sarah M. Alhijji, Saleh M. Alenizy, Mohammad A. Iskandar, Mounir Feitosa, Sabrina |
author_sort | Labban, Nawaf |
collection | PubMed |
description | The aim of this study was to compare the surface roughness and gloss of polymer-infiltrated ceramics after simulated in vitro toothbrushing in different storage mediums. Four polymer- infiltrated ceramics were evaluated, Lava ultimate (LU), Vita enamic (EN), Shofu (SH), and Crystal ultra (CU). The control group was a feldspathic ceramic, Vita Mark II (VM). One hundred and twenty specimens (12 × 14 × 2.5 mm) were prepared using a precision saw. For each material (n = 24), the specimens were allocated into two groups, polished and stained. The specimens of each group were stored (for 7 days) in either citric acid (0.2N) or distilled water. Data for surface gloss (ΔE*(SCE-SCI)) and roughness (Ra) were evaluated before (baseline) and after simulated toothbrushing. For toothbrushing simulation, a toothpaste slurry containing a toothpaste of 100 relative dentin abrasion (RDA) and 0.3 ml distilled water was used for 3650 cycles (7300 strokes) for each specimen. Data were analyzed using t-test and ANOVA. A p-value of ≤ to 0.05 was considered significant. The highest mean value of surface gloss was identified in CU (stained—water) (4.3 (0.47)) (ΔE*) and EN (stained—acid) (4.3 (1.00)) (ΔE*) specimens, whereas the lowest mean value was shown by SH (stained—acid) (2.04 (0.42)) (ΔE*) samples. The highest mean value of surface roughness was observed in SH (0.40 (0.99)) Ra (stained—acid) whereas the lowest in VM (0.13 (0.039)) Ra (polished— water). A significant difference (p < 0.05) was observed in surface roughness and gloss between the materials with simulated toothbrushing, except in VM and LU, respectively. Therefore, it can be concluded that simulated toothbrushing impacts on surface roughness and gloss, irrespective of the storage medium. |
format | Online Article Text |
id | pubmed-8587314 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-85873142021-11-13 Influence of Toothbrush Abrasion and Surface Treatments on Roughness and Gloss of Polymer-Infiltrated Ceramics Labban, Nawaf Al Amri, Mohammad D. Alnafaiy, Sarah M. Alhijji, Saleh M. Alenizy, Mohammad A. Iskandar, Mounir Feitosa, Sabrina Polymers (Basel) Article The aim of this study was to compare the surface roughness and gloss of polymer-infiltrated ceramics after simulated in vitro toothbrushing in different storage mediums. Four polymer- infiltrated ceramics were evaluated, Lava ultimate (LU), Vita enamic (EN), Shofu (SH), and Crystal ultra (CU). The control group was a feldspathic ceramic, Vita Mark II (VM). One hundred and twenty specimens (12 × 14 × 2.5 mm) were prepared using a precision saw. For each material (n = 24), the specimens were allocated into two groups, polished and stained. The specimens of each group were stored (for 7 days) in either citric acid (0.2N) or distilled water. Data for surface gloss (ΔE*(SCE-SCI)) and roughness (Ra) were evaluated before (baseline) and after simulated toothbrushing. For toothbrushing simulation, a toothpaste slurry containing a toothpaste of 100 relative dentin abrasion (RDA) and 0.3 ml distilled water was used for 3650 cycles (7300 strokes) for each specimen. Data were analyzed using t-test and ANOVA. A p-value of ≤ to 0.05 was considered significant. The highest mean value of surface gloss was identified in CU (stained—water) (4.3 (0.47)) (ΔE*) and EN (stained—acid) (4.3 (1.00)) (ΔE*) specimens, whereas the lowest mean value was shown by SH (stained—acid) (2.04 (0.42)) (ΔE*) samples. The highest mean value of surface roughness was observed in SH (0.40 (0.99)) Ra (stained—acid) whereas the lowest in VM (0.13 (0.039)) Ra (polished— water). A significant difference (p < 0.05) was observed in surface roughness and gloss between the materials with simulated toothbrushing, except in VM and LU, respectively. Therefore, it can be concluded that simulated toothbrushing impacts on surface roughness and gloss, irrespective of the storage medium. MDPI 2021-10-27 /pmc/articles/PMC8587314/ /pubmed/34771250 http://dx.doi.org/10.3390/polym13213694 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Labban, Nawaf Al Amri, Mohammad D. Alnafaiy, Sarah M. Alhijji, Saleh M. Alenizy, Mohammad A. Iskandar, Mounir Feitosa, Sabrina Influence of Toothbrush Abrasion and Surface Treatments on Roughness and Gloss of Polymer-Infiltrated Ceramics |
title | Influence of Toothbrush Abrasion and Surface Treatments on Roughness and Gloss of Polymer-Infiltrated Ceramics |
title_full | Influence of Toothbrush Abrasion and Surface Treatments on Roughness and Gloss of Polymer-Infiltrated Ceramics |
title_fullStr | Influence of Toothbrush Abrasion and Surface Treatments on Roughness and Gloss of Polymer-Infiltrated Ceramics |
title_full_unstemmed | Influence of Toothbrush Abrasion and Surface Treatments on Roughness and Gloss of Polymer-Infiltrated Ceramics |
title_short | Influence of Toothbrush Abrasion and Surface Treatments on Roughness and Gloss of Polymer-Infiltrated Ceramics |
title_sort | influence of toothbrush abrasion and surface treatments on roughness and gloss of polymer-infiltrated ceramics |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8587314/ https://www.ncbi.nlm.nih.gov/pubmed/34771250 http://dx.doi.org/10.3390/polym13213694 |
work_keys_str_mv | AT labbannawaf influenceoftoothbrushabrasionandsurfacetreatmentsonroughnessandglossofpolymerinfiltratedceramics AT alamrimohammadd influenceoftoothbrushabrasionandsurfacetreatmentsonroughnessandglossofpolymerinfiltratedceramics AT alnafaiysarahm influenceoftoothbrushabrasionandsurfacetreatmentsonroughnessandglossofpolymerinfiltratedceramics AT alhijjisalehm influenceoftoothbrushabrasionandsurfacetreatmentsonroughnessandglossofpolymerinfiltratedceramics AT alenizymohammada influenceoftoothbrushabrasionandsurfacetreatmentsonroughnessandglossofpolymerinfiltratedceramics AT iskandarmounir influenceoftoothbrushabrasionandsurfacetreatmentsonroughnessandglossofpolymerinfiltratedceramics AT feitosasabrina influenceoftoothbrushabrasionandsurfacetreatmentsonroughnessandglossofpolymerinfiltratedceramics |