Cargando…
Validating Poly(3,4-ethylene dioxythiophene) Polystyrene Sulfonate-Based Textile Electroencephalography Electrodes by a Textile-Based Head Phantom
It is important to go through a validation process when developing new electroencephalography (EEG) electrodes, but it is impossible to keep the human mind constant, making the process difficult. It is also very difficult to identify noise and signals as the input signal is unknown. In this work, we...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8587322/ https://www.ncbi.nlm.nih.gov/pubmed/34771186 http://dx.doi.org/10.3390/polym13213629 |
_version_ | 1784598114078818304 |
---|---|
author | Tseghai, Granch Berhe Malengier, Benny Fante, Kinde Anlay Van Langenhove, Lieva |
author_facet | Tseghai, Granch Berhe Malengier, Benny Fante, Kinde Anlay Van Langenhove, Lieva |
author_sort | Tseghai, Granch Berhe |
collection | PubMed |
description | It is important to go through a validation process when developing new electroencephalography (EEG) electrodes, but it is impossible to keep the human mind constant, making the process difficult. It is also very difficult to identify noise and signals as the input signal is unknown. In this work, we have validated textile-based EEG electrodes constructed from a poly(3,4-ethylene dioxythiophene) polystyrene sulfonate:/polydimethylsiloxane coated cotton fabric using a textile-based head phantom. The performance of the textile-based electrode has also been compared against a commercial dry electrode. The textile electrodes collected a signal to a smaller skin-to-electrode impedance (−18.9%) and a higher signal-to-noise ratio (+3.45%) than Ag/AgCl dry electrodes. From an EEGLAB, it was observed that the inter-trial coherence and event-related spectral perturbation graphs of the textile-based electrodes were identical to the Ag/AgCl electrodes. Thus, these textile-based electrodes can be a potential alternative to monitor brain activity. |
format | Online Article Text |
id | pubmed-8587322 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-85873222021-11-13 Validating Poly(3,4-ethylene dioxythiophene) Polystyrene Sulfonate-Based Textile Electroencephalography Electrodes by a Textile-Based Head Phantom Tseghai, Granch Berhe Malengier, Benny Fante, Kinde Anlay Van Langenhove, Lieva Polymers (Basel) Article It is important to go through a validation process when developing new electroencephalography (EEG) electrodes, but it is impossible to keep the human mind constant, making the process difficult. It is also very difficult to identify noise and signals as the input signal is unknown. In this work, we have validated textile-based EEG electrodes constructed from a poly(3,4-ethylene dioxythiophene) polystyrene sulfonate:/polydimethylsiloxane coated cotton fabric using a textile-based head phantom. The performance of the textile-based electrode has also been compared against a commercial dry electrode. The textile electrodes collected a signal to a smaller skin-to-electrode impedance (−18.9%) and a higher signal-to-noise ratio (+3.45%) than Ag/AgCl dry electrodes. From an EEGLAB, it was observed that the inter-trial coherence and event-related spectral perturbation graphs of the textile-based electrodes were identical to the Ag/AgCl electrodes. Thus, these textile-based electrodes can be a potential alternative to monitor brain activity. MDPI 2021-10-21 /pmc/articles/PMC8587322/ /pubmed/34771186 http://dx.doi.org/10.3390/polym13213629 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Tseghai, Granch Berhe Malengier, Benny Fante, Kinde Anlay Van Langenhove, Lieva Validating Poly(3,4-ethylene dioxythiophene) Polystyrene Sulfonate-Based Textile Electroencephalography Electrodes by a Textile-Based Head Phantom |
title | Validating Poly(3,4-ethylene dioxythiophene) Polystyrene Sulfonate-Based Textile Electroencephalography Electrodes by a Textile-Based Head Phantom |
title_full | Validating Poly(3,4-ethylene dioxythiophene) Polystyrene Sulfonate-Based Textile Electroencephalography Electrodes by a Textile-Based Head Phantom |
title_fullStr | Validating Poly(3,4-ethylene dioxythiophene) Polystyrene Sulfonate-Based Textile Electroencephalography Electrodes by a Textile-Based Head Phantom |
title_full_unstemmed | Validating Poly(3,4-ethylene dioxythiophene) Polystyrene Sulfonate-Based Textile Electroencephalography Electrodes by a Textile-Based Head Phantom |
title_short | Validating Poly(3,4-ethylene dioxythiophene) Polystyrene Sulfonate-Based Textile Electroencephalography Electrodes by a Textile-Based Head Phantom |
title_sort | validating poly(3,4-ethylene dioxythiophene) polystyrene sulfonate-based textile electroencephalography electrodes by a textile-based head phantom |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8587322/ https://www.ncbi.nlm.nih.gov/pubmed/34771186 http://dx.doi.org/10.3390/polym13213629 |
work_keys_str_mv | AT tseghaigranchberhe validatingpoly34ethylenedioxythiophenepolystyrenesulfonatebasedtextileelectroencephalographyelectrodesbyatextilebasedheadphantom AT malengierbenny validatingpoly34ethylenedioxythiophenepolystyrenesulfonatebasedtextileelectroencephalographyelectrodesbyatextilebasedheadphantom AT fantekindeanlay validatingpoly34ethylenedioxythiophenepolystyrenesulfonatebasedtextileelectroencephalographyelectrodesbyatextilebasedheadphantom AT vanlangenhovelieva validatingpoly34ethylenedioxythiophenepolystyrenesulfonatebasedtextileelectroencephalographyelectrodesbyatextilebasedheadphantom |