Cargando…

Performance of Circular Concrete-Filled FRP-Grooved Steel Composite Tube Columns under Axial Compression

A new structure termed “concrete-filled FRP-grooved steel composite tube (CFGCT) column” is proposed, which is composed of a stress-released steel tube (i.e., grooved steel tube), fiber-reinforced polymer (FRP) and concrete. Axial load tests were carried out on twenty-four specimens to investigate t...

Descripción completa

Detalles Bibliográficos
Autores principales: Miao, Kunting, Wei, Yang, Zhang, Xi, Zheng, Kaiqi, Dong, Fenghui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8587666/
https://www.ncbi.nlm.nih.gov/pubmed/34771195
http://dx.doi.org/10.3390/polym13213638
_version_ 1784598209708949504
author Miao, Kunting
Wei, Yang
Zhang, Xi
Zheng, Kaiqi
Dong, Fenghui
author_facet Miao, Kunting
Wei, Yang
Zhang, Xi
Zheng, Kaiqi
Dong, Fenghui
author_sort Miao, Kunting
collection PubMed
description A new structure termed “concrete-filled FRP-grooved steel composite tube (CFGCT) column” is proposed, which is composed of a stress-released steel tube (i.e., grooved steel tube), fiber-reinforced polymer (FRP) and concrete. Axial load tests were carried out on twenty-four specimens to investigate the constraint effect of this structure. Three main experimental variables were considered: the steel tube thickness, the FRP type, and the FRP layer. The failure modes, stress-strain relationships and the effect of the main experimental variables were discussed. The stress-strain curves of this new structure are composed of an initial linear part, a nonlinear transition part, a strengthening part and a residual part. The test results demonstrate that the bearing capacity of the structure was improved, and that the mechanical mechanism of the structure was simplified due to the stress-released grooves. Based on the test results and previous studies, formulas for calculating the ultimate stress (f(cu)), ultimate strain (ε(cu)), peak stress (f(cc)) and peak strain (ε(cc)) were proposed. In addition, models for predicting the stress-strain curves of CFGCT columns were put forward, and the models could precisely simulate the stress-strain curve of this new composite structure. Hence, this study indicates that a structure composed of FRP and stress-released steel tube can effectively constrain concrete.
format Online
Article
Text
id pubmed-8587666
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85876662021-11-13 Performance of Circular Concrete-Filled FRP-Grooved Steel Composite Tube Columns under Axial Compression Miao, Kunting Wei, Yang Zhang, Xi Zheng, Kaiqi Dong, Fenghui Polymers (Basel) Article A new structure termed “concrete-filled FRP-grooved steel composite tube (CFGCT) column” is proposed, which is composed of a stress-released steel tube (i.e., grooved steel tube), fiber-reinforced polymer (FRP) and concrete. Axial load tests were carried out on twenty-four specimens to investigate the constraint effect of this structure. Three main experimental variables were considered: the steel tube thickness, the FRP type, and the FRP layer. The failure modes, stress-strain relationships and the effect of the main experimental variables were discussed. The stress-strain curves of this new structure are composed of an initial linear part, a nonlinear transition part, a strengthening part and a residual part. The test results demonstrate that the bearing capacity of the structure was improved, and that the mechanical mechanism of the structure was simplified due to the stress-released grooves. Based on the test results and previous studies, formulas for calculating the ultimate stress (f(cu)), ultimate strain (ε(cu)), peak stress (f(cc)) and peak strain (ε(cc)) were proposed. In addition, models for predicting the stress-strain curves of CFGCT columns were put forward, and the models could precisely simulate the stress-strain curve of this new composite structure. Hence, this study indicates that a structure composed of FRP and stress-released steel tube can effectively constrain concrete. MDPI 2021-10-22 /pmc/articles/PMC8587666/ /pubmed/34771195 http://dx.doi.org/10.3390/polym13213638 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Miao, Kunting
Wei, Yang
Zhang, Xi
Zheng, Kaiqi
Dong, Fenghui
Performance of Circular Concrete-Filled FRP-Grooved Steel Composite Tube Columns under Axial Compression
title Performance of Circular Concrete-Filled FRP-Grooved Steel Composite Tube Columns under Axial Compression
title_full Performance of Circular Concrete-Filled FRP-Grooved Steel Composite Tube Columns under Axial Compression
title_fullStr Performance of Circular Concrete-Filled FRP-Grooved Steel Composite Tube Columns under Axial Compression
title_full_unstemmed Performance of Circular Concrete-Filled FRP-Grooved Steel Composite Tube Columns under Axial Compression
title_short Performance of Circular Concrete-Filled FRP-Grooved Steel Composite Tube Columns under Axial Compression
title_sort performance of circular concrete-filled frp-grooved steel composite tube columns under axial compression
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8587666/
https://www.ncbi.nlm.nih.gov/pubmed/34771195
http://dx.doi.org/10.3390/polym13213638
work_keys_str_mv AT miaokunting performanceofcircularconcretefilledfrpgroovedsteelcompositetubecolumnsunderaxialcompression
AT weiyang performanceofcircularconcretefilledfrpgroovedsteelcompositetubecolumnsunderaxialcompression
AT zhangxi performanceofcircularconcretefilledfrpgroovedsteelcompositetubecolumnsunderaxialcompression
AT zhengkaiqi performanceofcircularconcretefilledfrpgroovedsteelcompositetubecolumnsunderaxialcompression
AT dongfenghui performanceofcircularconcretefilledfrpgroovedsteelcompositetubecolumnsunderaxialcompression