Cargando…
3D cone-beam C.T. imaging used to determine the effect of disinfection protocols on the dimensional stability of full arch impressions
AIM: This study aimed to investigate the dimensional stability of irreversible hydrocolloid and polyvinylsiloxane (P.V.S.) impressions after exposure to four commercial disinfectants using cone-beam computed tomography (CBCT). MATERIALS AND METHODS: Two different impression materials were tested: ir...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8589573/ https://www.ncbi.nlm.nih.gov/pubmed/34803286 http://dx.doi.org/10.1016/j.sdentj.2020.12.001 |
_version_ | 1784598755959373824 |
---|---|
author | Hsu, Kuei-ling Balhaddad, Abdulrahman A. Martini Garcia, Isadora Collares, Fabrício Mezzomo Dhar, Vineet DePaola, Louis Melo, Mary Anne |
author_facet | Hsu, Kuei-ling Balhaddad, Abdulrahman A. Martini Garcia, Isadora Collares, Fabrício Mezzomo Dhar, Vineet DePaola, Louis Melo, Mary Anne |
author_sort | Hsu, Kuei-ling |
collection | PubMed |
description | AIM: This study aimed to investigate the dimensional stability of irreversible hydrocolloid and polyvinylsiloxane (P.V.S.) impressions after exposure to four commercial disinfectants using cone-beam computed tomography (CBCT). MATERIALS AND METHODS: Two different impression materials were tested: irreversible hydrocolloid and P.V.S. Four disinfection solutions were applied: BirexSE, Opti-Cide3, COEfect MinuteSpray, and CaviCide Spray. Distilled water was used as a control group. Each solution remained in contact with the impression for 5 min. Additional contact time of 5 min compromises time for scanning. The materials were evaluated for dimensional stability after the impression of a maxillary complete edentulous template via CBCT before and after being in contact with the disinfectant agents. Measurements were assessed on the digital models from A-B, B-C, and C-A points. Paired analyses (Wilcoxon Signed Rank test or paired Student's t-test) were used to analyze each measurement before and after the contact with the disinfectant agents. The variance for each measurement was also analyzed via a one-way analysis of variance or Kruskal-Wallis. RESULTS: Overall, there were no statistical differences among the points measurements in the irreversible hydrocolloid or P.V.S. between initial and final assessments (p > 0.05). The used disinfectant agents in this study did not influence each measurement's variation on irreversible hydrocolloid or P.V.S. (p > 0.05). All agents showed an effect on the dimensional stability of both impression materials. The differences in the three dimensions ranged between 0.34 and 1.54%. CONCLUSION: Within 10 min of removing the impression from the master cast, is study's findings indicated that the four commercially available disinfectants did not influence the dimensional stability of irreversible hydrocolloid or P.V.S. Further studies should be performed to elucidate the antimicrobial effect of these solutions applied as a spray on the surface of irreversible hydrocolloid and P.V.S. impressions. |
format | Online Article Text |
id | pubmed-8589573 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-85895732021-11-19 3D cone-beam C.T. imaging used to determine the effect of disinfection protocols on the dimensional stability of full arch impressions Hsu, Kuei-ling Balhaddad, Abdulrahman A. Martini Garcia, Isadora Collares, Fabrício Mezzomo Dhar, Vineet DePaola, Louis Melo, Mary Anne Saudi Dent J Original Article AIM: This study aimed to investigate the dimensional stability of irreversible hydrocolloid and polyvinylsiloxane (P.V.S.) impressions after exposure to four commercial disinfectants using cone-beam computed tomography (CBCT). MATERIALS AND METHODS: Two different impression materials were tested: irreversible hydrocolloid and P.V.S. Four disinfection solutions were applied: BirexSE, Opti-Cide3, COEfect MinuteSpray, and CaviCide Spray. Distilled water was used as a control group. Each solution remained in contact with the impression for 5 min. Additional contact time of 5 min compromises time for scanning. The materials were evaluated for dimensional stability after the impression of a maxillary complete edentulous template via CBCT before and after being in contact with the disinfectant agents. Measurements were assessed on the digital models from A-B, B-C, and C-A points. Paired analyses (Wilcoxon Signed Rank test or paired Student's t-test) were used to analyze each measurement before and after the contact with the disinfectant agents. The variance for each measurement was also analyzed via a one-way analysis of variance or Kruskal-Wallis. RESULTS: Overall, there were no statistical differences among the points measurements in the irreversible hydrocolloid or P.V.S. between initial and final assessments (p > 0.05). The used disinfectant agents in this study did not influence each measurement's variation on irreversible hydrocolloid or P.V.S. (p > 0.05). All agents showed an effect on the dimensional stability of both impression materials. The differences in the three dimensions ranged between 0.34 and 1.54%. CONCLUSION: Within 10 min of removing the impression from the master cast, is study's findings indicated that the four commercially available disinfectants did not influence the dimensional stability of irreversible hydrocolloid or P.V.S. Further studies should be performed to elucidate the antimicrobial effect of these solutions applied as a spray on the surface of irreversible hydrocolloid and P.V.S. impressions. Elsevier 2021-11 2020-12-10 /pmc/articles/PMC8589573/ /pubmed/34803286 http://dx.doi.org/10.1016/j.sdentj.2020.12.001 Text en © 2020 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Hsu, Kuei-ling Balhaddad, Abdulrahman A. Martini Garcia, Isadora Collares, Fabrício Mezzomo Dhar, Vineet DePaola, Louis Melo, Mary Anne 3D cone-beam C.T. imaging used to determine the effect of disinfection protocols on the dimensional stability of full arch impressions |
title | 3D cone-beam C.T. imaging used to determine the effect of disinfection protocols on the dimensional stability of full arch impressions |
title_full | 3D cone-beam C.T. imaging used to determine the effect of disinfection protocols on the dimensional stability of full arch impressions |
title_fullStr | 3D cone-beam C.T. imaging used to determine the effect of disinfection protocols on the dimensional stability of full arch impressions |
title_full_unstemmed | 3D cone-beam C.T. imaging used to determine the effect of disinfection protocols on the dimensional stability of full arch impressions |
title_short | 3D cone-beam C.T. imaging used to determine the effect of disinfection protocols on the dimensional stability of full arch impressions |
title_sort | 3d cone-beam c.t. imaging used to determine the effect of disinfection protocols on the dimensional stability of full arch impressions |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8589573/ https://www.ncbi.nlm.nih.gov/pubmed/34803286 http://dx.doi.org/10.1016/j.sdentj.2020.12.001 |
work_keys_str_mv | AT hsukueiling 3dconebeamctimagingusedtodeterminetheeffectofdisinfectionprotocolsonthedimensionalstabilityoffullarchimpressions AT balhaddadabdulrahmana 3dconebeamctimagingusedtodeterminetheeffectofdisinfectionprotocolsonthedimensionalstabilityoffullarchimpressions AT martinigarciaisadora 3dconebeamctimagingusedtodeterminetheeffectofdisinfectionprotocolsonthedimensionalstabilityoffullarchimpressions AT collaresfabriciomezzomo 3dconebeamctimagingusedtodeterminetheeffectofdisinfectionprotocolsonthedimensionalstabilityoffullarchimpressions AT dharvineet 3dconebeamctimagingusedtodeterminetheeffectofdisinfectionprotocolsonthedimensionalstabilityoffullarchimpressions AT depaolalouis 3dconebeamctimagingusedtodeterminetheeffectofdisinfectionprotocolsonthedimensionalstabilityoffullarchimpressions AT melomaryanne 3dconebeamctimagingusedtodeterminetheeffectofdisinfectionprotocolsonthedimensionalstabilityoffullarchimpressions |