Evaluating a calcium-aware kernel for CT CAC scoring with varying surrounding materials and heart rates: a dynamic phantom study
OBJECTIVES: The purpose of this study was twofold. First, the influence of a novel calcium-aware (Ca-aware) computed tomography (CT) reconstruction technique on coronary artery calcium (CAC) scores surrounded by a variety of tissues was assessed. Second, the performance of the Ca-aware reconstructio...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8589753/ https://www.ncbi.nlm.nih.gov/pubmed/34050386 http://dx.doi.org/10.1007/s00330-021-08076-5 |
_version_ | 1784598798934212608 |
---|---|
author | van der Werf, Niels R. Booij, Ronald Schmidt, Bernhard Flohr, Thomas G. Leiner, Tim de Groen, Joël J. Bos, Daniël Budde, Ricardo P. J. Willemink, Martin J. Greuter, Marcel J. W. |
author_facet | van der Werf, Niels R. Booij, Ronald Schmidt, Bernhard Flohr, Thomas G. Leiner, Tim de Groen, Joël J. Bos, Daniël Budde, Ricardo P. J. Willemink, Martin J. Greuter, Marcel J. W. |
author_sort | van der Werf, Niels R. |
collection | PubMed |
description | OBJECTIVES: The purpose of this study was twofold. First, the influence of a novel calcium-aware (Ca-aware) computed tomography (CT) reconstruction technique on coronary artery calcium (CAC) scores surrounded by a variety of tissues was assessed. Second, the performance of the Ca-aware reconstruction technique on moving CAC was evaluated with a dynamic phantom. METHODS: An artificial coronary artery, containing two CAC of equal size and different densities (196 ± 3, 380 ± 2 mg hydroxyapatite cm(−3)), was moved in the center compartment of an anthropomorphic thorax phantom at different heart rates. The center compartment was filled with mixtures, which resembled fat, water, and soft tissue equivalent CT numbers. Raw data was acquired with a routine clinical CAC protocol, at 120 peak kilovolt (kVp). Subsequently, reduced tube voltage (100 kVp) and tin-filtration (150Sn kVp) acquisitions were performed. Raw data was reconstructed with a standard and a novel Ca-aware reconstruction technique. Agatston scores of all reconstructions were compared with the reference (120 kVp) and standard reconstruction technique, with relevant deviations defined as > 10%. RESULTS: For all heart rates, Agatston scores for CAC submerged in fat were comparable to the reference, for the reduced-kVp acquisition with Ca-aware reconstruction kernel. For water and soft tissue, medium-density Agatston scores were again comparable to the reference for all heart rates. Low-density Agatston scores showed relevant deviations, up to 15% and 23% for water and soft tissue, respectively. CONCLUSION: CT CAC scoring with varying surrounding materials and heart rates is feasible at patient-specific tube voltages with the novel Ca-aware reconstruction technique. KEY POINTS: • A dedicated calcium-aware reconstruction kernel results in similar Agatston scores for CAC surrounded by fatty materials regardless of CAC density and heart rate. • Application of a dedicated calcium-aware reconstruction kernel allows for radiation dose reduction. • Mass scores determined with CT underestimated physical mass. |
format | Online Article Text |
id | pubmed-8589753 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-85897532021-11-15 Evaluating a calcium-aware kernel for CT CAC scoring with varying surrounding materials and heart rates: a dynamic phantom study van der Werf, Niels R. Booij, Ronald Schmidt, Bernhard Flohr, Thomas G. Leiner, Tim de Groen, Joël J. Bos, Daniël Budde, Ricardo P. J. Willemink, Martin J. Greuter, Marcel J. W. Eur Radiol Computed Tomography OBJECTIVES: The purpose of this study was twofold. First, the influence of a novel calcium-aware (Ca-aware) computed tomography (CT) reconstruction technique on coronary artery calcium (CAC) scores surrounded by a variety of tissues was assessed. Second, the performance of the Ca-aware reconstruction technique on moving CAC was evaluated with a dynamic phantom. METHODS: An artificial coronary artery, containing two CAC of equal size and different densities (196 ± 3, 380 ± 2 mg hydroxyapatite cm(−3)), was moved in the center compartment of an anthropomorphic thorax phantom at different heart rates. The center compartment was filled with mixtures, which resembled fat, water, and soft tissue equivalent CT numbers. Raw data was acquired with a routine clinical CAC protocol, at 120 peak kilovolt (kVp). Subsequently, reduced tube voltage (100 kVp) and tin-filtration (150Sn kVp) acquisitions were performed. Raw data was reconstructed with a standard and a novel Ca-aware reconstruction technique. Agatston scores of all reconstructions were compared with the reference (120 kVp) and standard reconstruction technique, with relevant deviations defined as > 10%. RESULTS: For all heart rates, Agatston scores for CAC submerged in fat were comparable to the reference, for the reduced-kVp acquisition with Ca-aware reconstruction kernel. For water and soft tissue, medium-density Agatston scores were again comparable to the reference for all heart rates. Low-density Agatston scores showed relevant deviations, up to 15% and 23% for water and soft tissue, respectively. CONCLUSION: CT CAC scoring with varying surrounding materials and heart rates is feasible at patient-specific tube voltages with the novel Ca-aware reconstruction technique. KEY POINTS: • A dedicated calcium-aware reconstruction kernel results in similar Agatston scores for CAC surrounded by fatty materials regardless of CAC density and heart rate. • Application of a dedicated calcium-aware reconstruction kernel allows for radiation dose reduction. • Mass scores determined with CT underestimated physical mass. Springer Berlin Heidelberg 2021-05-28 2021 /pmc/articles/PMC8589753/ /pubmed/34050386 http://dx.doi.org/10.1007/s00330-021-08076-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Computed Tomography van der Werf, Niels R. Booij, Ronald Schmidt, Bernhard Flohr, Thomas G. Leiner, Tim de Groen, Joël J. Bos, Daniël Budde, Ricardo P. J. Willemink, Martin J. Greuter, Marcel J. W. Evaluating a calcium-aware kernel for CT CAC scoring with varying surrounding materials and heart rates: a dynamic phantom study |
title | Evaluating a calcium-aware kernel for CT CAC scoring with varying surrounding materials and heart rates: a dynamic phantom study |
title_full | Evaluating a calcium-aware kernel for CT CAC scoring with varying surrounding materials and heart rates: a dynamic phantom study |
title_fullStr | Evaluating a calcium-aware kernel for CT CAC scoring with varying surrounding materials and heart rates: a dynamic phantom study |
title_full_unstemmed | Evaluating a calcium-aware kernel for CT CAC scoring with varying surrounding materials and heart rates: a dynamic phantom study |
title_short | Evaluating a calcium-aware kernel for CT CAC scoring with varying surrounding materials and heart rates: a dynamic phantom study |
title_sort | evaluating a calcium-aware kernel for ct cac scoring with varying surrounding materials and heart rates: a dynamic phantom study |
topic | Computed Tomography |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8589753/ https://www.ncbi.nlm.nih.gov/pubmed/34050386 http://dx.doi.org/10.1007/s00330-021-08076-5 |
work_keys_str_mv | AT vanderwerfnielsr evaluatingacalciumawarekernelforctcacscoringwithvaryingsurroundingmaterialsandheartratesadynamicphantomstudy AT booijronald evaluatingacalciumawarekernelforctcacscoringwithvaryingsurroundingmaterialsandheartratesadynamicphantomstudy AT schmidtbernhard evaluatingacalciumawarekernelforctcacscoringwithvaryingsurroundingmaterialsandheartratesadynamicphantomstudy AT flohrthomasg evaluatingacalciumawarekernelforctcacscoringwithvaryingsurroundingmaterialsandheartratesadynamicphantomstudy AT leinertim evaluatingacalciumawarekernelforctcacscoringwithvaryingsurroundingmaterialsandheartratesadynamicphantomstudy AT degroenjoelj evaluatingacalciumawarekernelforctcacscoringwithvaryingsurroundingmaterialsandheartratesadynamicphantomstudy AT bosdaniel evaluatingacalciumawarekernelforctcacscoringwithvaryingsurroundingmaterialsandheartratesadynamicphantomstudy AT buddericardopj evaluatingacalciumawarekernelforctcacscoringwithvaryingsurroundingmaterialsandheartratesadynamicphantomstudy AT willeminkmartinj evaluatingacalciumawarekernelforctcacscoringwithvaryingsurroundingmaterialsandheartratesadynamicphantomstudy AT greutermarceljw evaluatingacalciumawarekernelforctcacscoringwithvaryingsurroundingmaterialsandheartratesadynamicphantomstudy |